trusted seller
Flow Over A Notch
Flow Over A Notch

Flow Over A Notch

MOQ : 1 , , Unit

Flow Over A Notch Specification

  • Measuring Range
  • Water Head 0250 mm
  • Application
  • Fluid Machines Equipments
  • Humidity
  • Max 85% RH (Non-Condensing)
  • Max Height
  • Approx. 60 cm
  • Temperature
  • 5C to 40C
  • Display Type
  • Graduated Scale (Manual)
  • Product Type
  • Flow Over A Notch
  • Number of Specimens
  • 1 at a time
  • Operating Voltage
  • 230V AC
  • Hardness
  • Mild Steel Construction with powder coat
  • Specimen Size
  • Notch Plate: 100 mm x 100 mm (approx.)
  • Test Range
  • Discharge - up to 10 LPM (varies as per setup)
  • Frequency
  • 50 Hz
  • Accuracy
  • 1 mm for head measurement
  • Mounting Type
  • Bench-top
  • Resolution
  • 1 mm for scale graduation
  • Power Supply
  • 230V AC, 50Hz
  • Features
  • Interchangeable notch plates (Rectangular, Triangular, Trapezoidal)
  • Usage
  • Fluid Machines Equipments
  • Equipment Type
  • Flow Over A Notch Apparatus
  • Port Size
  • Inlet and Outlet: 1/2 inch
  • Response Time
  • Immediate (manual reading)
  • Automation Grade
  • Manual
  • Capacity
  • Water Tank: 25 Litres
  • Machine Weight
  • Approx. 30 kg
  • Control Mode
  • Manual Control
  • Flow Measurement
  • Using measuring tank and stopwatch
  • Water Circulation
  • Self-contained with centrifugal pump
  • Material of Construction
  • Stainless Steel/ Mild Steel with powder coated finish
  • Pump Capacity
  • 0.5 HP mono-block pump
  • Mobility
  • Caster wheels for easy movement
  • Safety
  • Overload protection for pump
  • Included Accessories
  • Set of different notches, scale, collecting tank, instruction manual
  • Installation Requirements
  • Requires water supply and drain
  • Experiment Capabilities
  • Study flow measurement over various types of notches, calculation of discharge coefficients
 

Flow Over A Notch Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Payment Terms
  • Cash Advance (CA), Telegraphic Transfer (T/T), Cheque, Letter of Credit (L/C), Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Flow Over A Notch

Flow Over A Notch:

Micro Teknik The unit consists of flow channel of proper length & width. The notch or weir is fitted, water supply is given at one end of channel. Water flow over notch or weir. Arrangement are made to measure the still level to determine the head.

Features:

    Interchangeable Brass/Aluminum notches.
    Measurement of head by scale.

Range Of Experiments:

    To determine coefficient of discharge through.
    60 V notch.
    Rectangular notch.

Specifications:

    Water storage tank.
    Notches 60 included angle V notch.
    Rectangular notch.
    Notch interchanges arrangement.
    Measuring tank & collecting tank & stop watch.

Service Required:

    Water supply.
    Suitable floor space of 2 m. x 2 m



Robust and Versatile Construction

Built with high-grade stainless steel or powder-coated mild steel, the apparatus offers excellent resistance to corrosion and long-term durability. Its benchtop design and caster wheels provide flexibility in placement and effortless mobility within laboratory environments. All components are finished to deliver reliable operation even under frequent usage.


Comprehensive Experimentation Capabilities

Students and researchers can explore the principles of flow over a notch, investigating discharge coefficients for different notch shapes. The apparatus comes with a set of interchangeable notches and graduated manual scale, enabling precise measurement of water head and discharge, enhancing hands-on understanding of fluid mechanics.


Safe, Efficient, and User-Friendly Operation

Featuring a self-contained water tank (25L) and 0.5 HP mono-block pump, the system is designed for safe operation with integrated overload protection. Manual controls offer straightforward operation, and clear scale graduation ensures immediate and accurate readings. All necessary installation requirements, including simple water supply and drainage connections, are clearly outlined.

FAQs of Flow Over A Notch:


Q: How do I measure the flow rate using the Flow Over A Notch Apparatus?

A: To measure flow rate, fill the apparatus with water, select the desired notch plate, and operate the centrifugal pump. Use the collecting tank and a stopwatch to determine the time taken to collect a known volume of water. Dividing the volume by the time gives you the flow rate.

Q: What types of notches are included with the equipment?

A: The apparatus is supplied with a set of interchangeable notch plates, including rectangular, triangular (V-notch), and trapezoidal profiles, allowing you to study the effects of different notch shapes on flow characteristics and discharge calculations.

Q: When should the pumps overload protection be checked?

A: Check the overload protection feature before each experimental session to ensure safe operation. If the pump trips during use, allow it to cool and inspect for obstructions or excessive load before restarting.

Q: Where is this equipment typically used?

A: This apparatus is primarily used in educational and research institutions, such as engineering colleges and technical training centers, for practical demonstrations and experiments involving fluid flow over notches.

Q: What is the process for changing notch plates during experiments?

A: To change a notch plate, first ensure the apparatus is turned off and the water flow is stopped. Remove the existing plate and securely install the chosen notch plate (100 mm x 100 mm), ensuring correct alignment to maintain measurement accuracy.

Q: How does the apparatus benefit fluid mechanics education?

A: The apparatus enables hands-on study of practical fluid flow concepts, making it easier to visualize and calculate discharge coefficients for various notch types. This interactive approach aids in comprehending theoretical principles and enhances student engagement.

Q: What installation requirements are necessary for setup?

A: The equipment requires an accessible water supply and suitable drainage for operation. A standard 230V AC, 50Hz power supply is necessary for the pump, and a bench-top location is recommended for secure mounting and ease of use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Computerised Flow Meter Caliberation Equipment

Computerised Flow Meter Caliberation Equipment

Minimum Order Quantity : 1 Piece

Usage : Fluid Machines Equipments

Product Type : Computerised Flow Meter Caliberation Equipment

Application : Fluid Machines Equipments

Power Supply : 230V AC, 50 Hz

Capacity : Up to 10,000 LPH

Energy Losses in Bend

Energy Losses in Bend

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Product Type : Energy Losses in Bend

Application : Fluid Machines Equipments

Power Supply : 220 V AC, 50 Hz

Capacity : Max fluid volume 10 Litres

Losses In Piping Systems

Losses In Piping Systems

Minimum Order Quantity : 1 , , Piece

Usage : Fluid Machines Equipments

Product Type : Losses In Piping Systems

Application : Fluid Machines Equipments

Power Supply : 220V AC, 50 Hz

Capacity : Variable, as per test setup

Bernoullis Theorem Demonstration

Bernoullis Theorem Demonstration

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Product Type : Bernoullis Theorem Demonstration

Application : Fluid Machines Equipments

Power Supply : Not required (Gravityfed)

Capacity : Tank volume approx. 1015 liters



Back to top