Flow Over A Notch Specification

  • Automation Grade
  • Manual
  • Resolution
  • 1 mm for scale graduation
  • Mounting Type
  • Bench-top
  • Humidity
  • Max 85% RH (Non-Condensing)
  • Display Type
  • Graduated Scale (Manual)
  • Features
  • Interchangeable notch plates (Rectangular, Triangular, Trapezoidal)
  • Specimen Size
  • Notch Plate: 100 mm x 100 mm (approx.)
  • Test Range
  • Discharge - up to 10 LPM (varies as per setup)
  • Power Supply
  • 230V AC, 50Hz
  • Operating Voltage
  • 230V AC
  • Temperature
  • 5C to 40C
  • Measuring Range
  • Water Head 0250 mm
  • Hardness
  • Mild Steel Construction with powder coat
  • Accuracy
  • 1 mm for head measurement
  • Port Size
  • Inlet and Outlet: 1/2 inch
  • Usage
  • Fluid Machines Equipments
  • Max Height
  • Approx. 60 cm
  • Number of Specimens
  • 1 at a time
  • Response Time
  • Immediate (manual reading)
  • Equipment Type
  • Flow Over A Notch Apparatus
  • Application
  • Fluid Machines Equipments
  • Frequency
  • 50 Hz
  • Product Type
  • Flow Over A Notch
  • Capacity
  • Water Tank: 25 Litres
  • Machine Weight
  • Approx. 30 kg
  • Control Mode
  • Manual Control
 

Flow Over A Notch Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Payment Terms
  • Cash Advance (CA), Telegraphic Transfer (T/T), Cheque, Letter of Credit (L/C), Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Flow Over A Notch

Flow Over A Notch:

Micro Teknik The unit consists of flow channel of proper length & width. The notch or weir is fitted, water supply is given at one end of channel. Water flow over notch or weir. Arrangement are made to measure the still level to determine the head.

Features:

    Interchangeable Brass/Aluminum notches.
    Measurement of head by scale.

Range Of Experiments:

    To determine coefficient of discharge through.
    60 V notch.
    Rectangular notch.

Specifications:

    Water storage tank.
    Notches 60 included angle V notch.
    Rectangular notch.
    Notch interchanges arrangement.
    Measuring tank & collecting tank & stop watch.

Service Required:

    Water supply.
    Suitable floor space of 2 m. x 2 m



Robust and Versatile Construction

Built with high-grade stainless steel or powder-coated mild steel, the apparatus offers excellent resistance to corrosion and long-term durability. Its benchtop design and caster wheels provide flexibility in placement and effortless mobility within laboratory environments. All components are finished to deliver reliable operation even under frequent usage.


Comprehensive Experimentation Capabilities

Students and researchers can explore the principles of flow over a notch, investigating discharge coefficients for different notch shapes. The apparatus comes with a set of interchangeable notches and graduated manual scale, enabling precise measurement of water head and discharge, enhancing hands-on understanding of fluid mechanics.


Safe, Efficient, and User-Friendly Operation

Featuring a self-contained water tank (25L) and 0.5 HP mono-block pump, the system is designed for safe operation with integrated overload protection. Manual controls offer straightforward operation, and clear scale graduation ensures immediate and accurate readings. All necessary installation requirements, including simple water supply and drainage connections, are clearly outlined.

FAQs of Flow Over A Notch:


Q: How do I measure the flow rate using the Flow Over A Notch Apparatus?

A: To measure flow rate, fill the apparatus with water, select the desired notch plate, and operate the centrifugal pump. Use the collecting tank and a stopwatch to determine the time taken to collect a known volume of water. Dividing the volume by the time gives you the flow rate.

Q: What types of notches are included with the equipment?

A: The apparatus is supplied with a set of interchangeable notch plates, including rectangular, triangular (V-notch), and trapezoidal profiles, allowing you to study the effects of different notch shapes on flow characteristics and discharge calculations.

Q: When should the pumps overload protection be checked?

A: Check the overload protection feature before each experimental session to ensure safe operation. If the pump trips during use, allow it to cool and inspect for obstructions or excessive load before restarting.

Q: Where is this equipment typically used?

A: This apparatus is primarily used in educational and research institutions, such as engineering colleges and technical training centers, for practical demonstrations and experiments involving fluid flow over notches.

Q: What is the process for changing notch plates during experiments?

A: To change a notch plate, first ensure the apparatus is turned off and the water flow is stopped. Remove the existing plate and securely install the chosen notch plate (100 mm x 100 mm), ensuring correct alignment to maintain measurement accuracy.

Q: How does the apparatus benefit fluid mechanics education?

A: The apparatus enables hands-on study of practical fluid flow concepts, making it easier to visualize and calculate discharge coefficients for various notch types. This interactive approach aids in comprehending theoretical principles and enhances student engagement.

Q: What installation requirements are necessary for setup?

A: The equipment requires an accessible water supply and suitable drainage for operation. A standard 230V AC, 50Hz power supply is necessary for the pump, and a bench-top location is recommended for secure mounting and ease of use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Aerodynamics Trainer

Aerodynamics Trainer

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Power Supply : 230V AC, 50 Hz, single phase

Application : Fluid Machines Equipments

Frequency : 50 Hz

Free and Forced Vortex Flow

Free and Forced Vortex Flow

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Power Supply : 230 V AC, 50 Hz, single phase

Application : Fluid Machines Equipments

Frequency : 50 Hz

Basic Hydrology Apparatus

Basic Hydrology Apparatus

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)

Pelton Wheel Turbine

Pelton Wheel Turbine

Minimum Order Quantity : 1 , , Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)



Back to top