Francis Turbine Apparatus Specification

  • Equipment Type
  • Hydraulic Laboratory Apparatus
  • Display Type
  • Digital Meter
  • Features
  • Compact, Transparent Working Section, Corrosion Resistant
  • Hardness
  • Structural Metallic Components
  • Measuring Range
  • Discharge, Pressure, Speed, Output Power
  • Specimen Size
  • Turbine Runner Dia: 150 mm approx.
  • Max Height
  • 1.2 m
  • Mounting Type
  • Bench Top
  • Test Range
  • Discharge: 020 LPM; Head: 020 m
  • Humidity
  • Up to 90% RH (Non-Condensing)
  • Power Supply
  • 230 V AC, 50 Hz
  • Interface Type
  • Panel Mount (Analog/Digital Interface)
  • Usage
  • Fluid Machines Equipments
  • Product Type
  • Francis Turbine Apparatus
  • Operating Voltage
  • 230 V
  • Port Size
  • Inlet: 25 mm, Outlet: 25 mm
  • Resolution
  • 0.01 unit (LPM, RPM, etc.)
  • Automation Grade
  • Manual / Semi-Automatic
  • Number of Specimens
  • Single Turbine Assembly
  • Application
  • Fluid Machines Equipments
  • Response Time
  • Instantaneous
  • Frequency
  • 50 Hz
  • Accuracy
  • 1% FS
  • Temperature
  • Room Temperature (10C to 40C)
  • Capacity
  • Flow Rate: 20 LPM max
  • Machine Weight
  • Approx. 100 kg
  • Test Speed
  • Variable, up to 1500 rpm
  • Control Mode
  • Manual / Digital Control
 

Francis Turbine Apparatus Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Payment Terms
  • Telegraphic Transfer (T/T), Letter of Credit (L/C), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Francis Turbine Apparatus

Francis Turbine

Specification of Francis Turbine:

  • Function of a Francis turbine.
  • Transparent front panel for observing the operating area.
  • Loading the turbine by use of the band brake.
  • Adjustable guide vanes for setting different angles of attack.
  • Marking on brake drum for non-contact speed measurement.
  • Instruments: spring balances for determining the torque, manometer shows pressure at turbine inlet
  • Flow determination by base module .
  • Water supply using the base module or via lab supply.

Dimensions and Weights:

  • L x W x H: 400x400x630mm
  • Weight: approx: 17kg
 

 

 



Transparent and Durable Construction

This apparatus includes a corrosion-resistant stainless steel runner and Perspex test section, allowing for clear observation and long-term durability. The mild steel frame provides stability, making it suitable for repeated laboratory use and varied test settings.


Advanced Instrumentation and Measurement

With integrated pressure gauges, RPM indicator, and a digital display meter, the Francis Turbine Apparatus ensures precise and real-time measurement of essential parameters including discharge, speed, and power output. Instant response and fine resolution support robust data collection.


Flexible Operation and Safety Assurance

Suitable for manual or digital control, operators can easily adjust test speeds up to 1500 rpm. Built-in safety features such as overload protection and emergency stop, coupled with self-contained water supply and comprehensive accessories, guarantee secure and adaptable usage for diverse testing requirements.

FAQs of Francis Turbine Apparatus:


Q: How does the Francis Turbine Apparatus measure flow and speed during experiments?

A: The apparatus uses a flow measuring tank and an RPM indicator to monitor discharge and turbined speed. All essential values, like flow rate and speed, are displayed digitally with an accuracy of 1% FS and resolution of 0.01 units.

Q: What materials are used in the construction of the Francis Turbine Apparatus?

A: It features a stainless steel runner for durability, a Perspex test section for visibility, and is mounted on a mild steel frame. These high-quality materials ensure corrosion resistance and reliable long-term usage.

Q: When should the overload protection and emergency stop features be used?

A: The overload protection and emergency stop features should be activated if abnormal loads, unexpected malfunctions, or safety hazards are detected during operation to protect both users and equipment.

Q: Where can this apparatus be installed for optimal performance?

A: The bench-top mounting design makes the Francis Turbine Apparatus ideal for laboratory environments, including educational institutions and research centers specializing in fluid mechanics and hydraulic machinery.

Q: What is the process for conducting a turbine efficiency test with this equipment?

A: Set up the turbine assembly, connect the appropriate hoses, and apply the desired flow rate and head using the self-contained water supply. Adjust the test speed manually or via digital control, then record the measurements from digital meters for analysis.

Q: How is the apparatus beneficial for fluid machines education?

A: Its transparent section, precise instrumentation, and comprehensive control features allow students and researchers to visually and quantitatively study turbine performance, deepening understanding of hydraulic principles.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Open Wind Tunnel

Open Wind Tunnel

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Automation Grade : SemiAutomatic

Application : Fluid Machines Equipments

Frequency : 50 Hz

Flow Channel of Fluid Mechanics Lab Equipments

Flow Channel of Fluid Mechanics Lab Equipments

Price 100 INR / Piece

Minimum Order Quantity : 1 , , Piece

Usage : Fluid Machines Equipments

Automation Grade : Semiautomatic

Application : Fluid Machines Equipments

Frequency : 50 Hz

Calibration Of A Pressure Gauge

Calibration Of A Pressure Gauge

Price 100 INR / Piece

Minimum Order Quantity : 1 , , Piece

Usage : Fluid Machines Equipments

Automation Grade : Manual

Application : Fluid Machines Equipments

Frequency : 50 Hz

Large Angle Stability System

Large Angle Stability System

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Automation Grade : SemiAutomatic

Application : Fluid Machines Equipments

Frequency : 50 Hz



Back to top