trusted seller
Losses In Piping Systems
Losses In Piping Systems

Losses In Piping Systems

MOQ : 1 , , Piece

Losses In Piping Systems Specification

  • Automation Grade
  • Manual
  • Specimen Size
  • Standard laboratory pipe diameters
  • Accuracy
  • High for educational and research purposes
  • Response Time
  • Immediate, manual observation
  • Equipment Type
  • Laboratory Experimental Apparatus
  • Frequency
  • 50 Hz
  • Test Range
  • Hydraulic losses measurement
  • Application
  • Fluid Machines Equipments
  • Product Type
  • Losses In Piping Systems
  • Temperature
  • Ambient
  • Measuring Range
  • Suits educational and laboratory demonstration
  • Display Type
  • Manometer, Graduated Scale
  • Power Supply
  • 220V AC, 50 Hz
  • Max Height
  • Adjustable, depends on setup
  • Humidity
  • Ambient
  • Operating Voltage
  • 220V AC
  • Resolution
  • Fine graduation manometer
  • Port Size
  • Compatible with standard laboratory piping
  • Number of Specimens
  • Multiple pipe sections
  • Features
  • Transparent piping sections, variety of fitting types, easy assembly and operation
  • Hardness
  • Corrosion-resistant materials
  • Usage
  • Fluid Machines Equipments
  • Mounting Type
  • Bench top
  • Capacity
  • Variable, as per test setup
  • Machine Weight
  • 30-50 kg approx.
  • Control Mode
  • Manual
  • Construction Material
  • Borosilicate glass, PVC, mild steel powder coated frame, brass/copper connectors
  • Water Supply Required
  • Standard tap water with recirculation tank
  • Manometer Fluid
  • Water or colored liquid
  • Manufacturer Warranty
  • 1 year against manufacturing defects
  • Included Fittings
  • Elbow, bend, contraction, expansion, valve, tee, various pipe lengths
  • Educational Use
  • Ideal for engineering laboratories and practical studies
  • Safety Features
  • Non-corrosive, leak-proof joints, sturdy base
  • Setup Type
  • Complete with all accessories and instruction manual
  • Flow Rate Measurement
  • Using measuring tank and stop watch
 

Losses In Piping Systems Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Letter of Credit (L/C), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Losses In Piping Systems

Losses In Piping Systems:



We are considered in the market to be one of the leading manufacturers and suppliers of this Losses In Piping Systems. For the purpose of maintaining this reputation, we indulge in the use of the best quality raw materials that are available. Manufactured in compliance with the set industrial norms, the offered product is one of the best that is available in the market. The offered apparatus is used widely for the purpose of measuring the rate of friction.

Specification

 

  • Demo panel for investigating the pressure losses in pipes
  • Demo panel on laboratory trolley
  • 10 different pipe sections for experiments
  • Pipe section selection using hose connections with rapid action hose couplings
  •  Standard measuring length of 1000mm for pipe friction measurements
  •  Manometer panel 300mmWG
  • Double manometer 850mmWG
  •  Differential pressure measuring unit 0..2000mbar, battery operated
  •  Flow rate measurement with variable-area flowmeter 1600ltr/h

 



Robust and Versatile Construction

Crafted from premium borosilicate glass, PVC, and mild steel powder-coated frames, the apparatus ensures both transparency for observation and resistance to corrosion. Brass or copper connectors provide leak-proof, long-lasting connections, while the sturdy base adds extra stability during laboratory operations.


Comprehensive Experimental Capability

Equipped with varied fittings like elbows, bends, contractions, expansions, tees, and valves, the system allows investigation of different piping arrangements and hydraulic losses. With multiple pipe sections and standard laboratory diameters, the apparatus can accommodate numerous test setups for educational and research experiments.


Precise Measurement and Easy Operation

Water flow rate is measured using a manual operation with a measuring tank and stopwatch, offering immediate response and observation. The manometer uses water or colored liquid for visibility, with a finely graduated scale ensuring high-resolution readings. The entire system supports bench-top mounting, easy assembly, and user-friendly operation.

FAQs of Losses In Piping Systems:


Q: How is the loss in piping systems measured using this apparatus?

A: Losses are measured by circulating standard tap water through various pipe fittings and sections, then assessing pressure differences with the manometer and quantifying flow rate using a measuring tank and stopwatch. This enables accurate evaluation of hydraulic losses under different conditions.

Q: What materials are used in the construction, and how do they benefit the setup?

A: The apparatus uses borosilicate glass and PVC for pipes, a powder-coated mild steel frame, and brass or copper connectors. These materials ensure transparency for observation, chemical resistance, mechanical strength, and non-corrosive, leak-proof performance, guaranteeing long-term reliability in laboratory environments.

Q: When should this apparatus be used in an educational setting?

A: This system is ideal for fluid mechanics or hydraulic engineering lab courses, typically during practical sessions on hydraulic losses, pipe friction, and fluid flow studies. Its suitable for both introductory and advanced engineering classes.

Q: Where can the apparatus be installed for optimal operation?

A: Designed for bench-top use, the apparatus fits standard laboratory environments. It should be placed on a stable, flat surface with access to a standard tap water supply and sufficient space for assembling all pipe sections and fittings.

Q: What is the process for setting up and operating the experiment?

A: Assembly involves connecting the selected pipes and fittings, filling the recirculation tank with water, and ensuring all joints are secure. Operation is manual: initiate water flow, adjust fittings as needed, then use the manometer and measuring tank with stopwatch to record all required readings.

Q: How does the use of transparent pipes and colored manometer fluid aid users?

A: Transparent piping allows direct observation of fluid movement and behavior within the system, enhancing educational demonstration. Colored manometer fluid improves visibility of liquid levels, making pressure readings easier and more accurate during experiments.

Q: What warranty and safety features does the apparatus offer?

A: The apparatus comes with a one-year warranty against manufacturing defects. Its safety is reinforced by non-corrosive materials, leak-proof joints, and a sturdy, stable base to prevent accidental tipping or spills during experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Osborne Reynold Demonstration Apparatus

Osborne Reynold Demonstration Apparatus

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Application : Fluid Machines Equipments

Product Type : Osborne Reynold Demonstration Apparatus

Mounting Type : Benchtop

Automation Grade : Manual

Flow Over Weirs Apparatus

Flow Over Weirs Apparatus

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Application : Fluid Machines Equipments

Product Type : Flow Over Weirs Apparatus

Mounting Type : Table Top

Automation Grade : Manual

Fluid Friction Apparatus

Fluid Friction Apparatus

Minimum Order Quantity : 1 Piece

Usage : Fluid Machines Equipments

Application : Fluid Machines Equipments

Product Type : Fluid Friction Apparatus

Mounting Type : Bench top

Automation Grade : Manual

Flow Meter Demonstration Unit

Flow Meter Demonstration Unit

Minimum Order Quantity : 1 , , Unit

Usage : Industrial

Mounting Type : Floor Mounting

Automation Grade : Automatic



Back to top