trusted seller
Exhaust Heat Analyzer
Exhaust Heat Analyzer

Exhaust Heat Analyzer

Price 10 INR/ Piece

MOQ : 1 Piece

Exhaust Heat Analyzer Specification

  • Accuracy
  • 1%
  • Model No
  • EHA-100
  • Application
  • Internal Combustion Engines
  • Feature
  • Accurate Heat Loss Measurement, Portable, Compact Design
  • Core Components
  • Temperature Indicator, Flow Control Valves, Inlet/Outlet Ports
  • Frequency
  • 50 Hz
  • Voltage
  • 220 V AC
  • Usage
  • Internal Combustion Engines
  • Power Source
  • Electric
  • Product Type
  • Exhaust Gas Calorimeter
  • Measurement Range
  • 0-600C
  • Temperature Range
  • 0 to 600C
  • Automation Grade
  • Manual
  • Capacity
  • 1 Unit
  • Equipment Materials
  • Stainless Steel
  • Type
  • Exhaust Gas Calorimeter
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 600 mm x 250 mm x 300 mm
  • Weight
  • Approx. 20 kg
 

Exhaust Heat Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Exhaust Heat Analyzer

Exhaust Gas Calorimeter:

Micro Teknik Determination of the thermal exhaust gas losses is essential when calculating an energy balance for internal combustion engines. Calorimetric measurement is an established method of doing this. It involves a largely complete and loss-free heat exchange between the exhaust gas and a cooling medium.

The exhaust gas calorimeter consists of an insulated stainless steel tank, through which the exhaust gas flows from bottom to top. While doing this, the exhaust gas gives up its heat almost completely to a finned pipe with cooling water flowing through it. The pipe is arranged in loops to achieve the maximum possible heat exchange area. Relevant temperatures (water and exhaust gas inlet and outlet) and the volumetric flow of the water are recorded electronically and displayed digitally using a measuring amplifier. The measuring amplifier is connected to the test stand using a data cable. This allows the measured data from the to be stored and processed using PC data acquisition.

Connected to a test engine using a heat-resistant exhaust gas hose.

 



Precision in Heat Loss Measurement

The EHA-100 provides accurate and reliable measurements of heat loss from internal combustion engine exhaust, essential for engine research and performance optimization. Its integrated flow meter and highly sensitive temperature indicators ensure results you can trust. Built with premium stainless steel and insulation, this analyzer remains corrosion-resistant even under rigorous operating conditions.


User-Friendly Setup and Operation

This bench-top units compact, portable structure allows for easy installation and transportation across labs and engine testing facilities. Manual controls supported by digital display make it simple for operators to monitor and adjust temperatures and flow rates. Its water-cooled system ensures stable operation, even during intensive testing periods, without risk of overheating.


Versatile Data Capture and Analysis

The EHA-100 caters to modern data needs by supporting both digital and analog outputs. This flexibility allows seamless integration with diverse monitoring and analysis systems, enhancing research productivity. Designed for high usability, the analyzer is suitable for distributors, exporters, manufacturers, suppliers, and traders in India and beyond.

FAQs of Exhaust Heat Analyzer:


Q: How does the Exhaust Heat Analyzer EHA-100 measure heat loss in internal combustion engines?

A: The EHA-100 uses a water-cooled heat exchanger along with precise temperature sensors and an integrated flow meter to measure the amount of heat lost via engine exhaust. By monitoring the temperature change and flow rate of exhaust gases, it accurately calculates heat transfer.

Q: What are the benefits of using a corrosion-resistant, stainless steel construction in this calorimeter?

A: The stainless steel body with insulation coating provides long-term durability, prevents corrosion from exhaust gases, and maintains accurate measurements even in harsh testing environments. This ensures consistent, reliable operation for various industrial and laboratory applications.

Q: When and where should I use the EHA-100 analyzer?

A: The EHA-100 is designed for bench-top use in laboratories and engine test facilities where measuring exhaust heat loss from internal combustion engines is required. Its portable, compact design facilitates flexible use across multiple locations in a temperature range of 5C to 45C.

Q: What types of data outputs does the analyzer provide?

A: The analyzer supports both digital and analog data outputs, making integration with various monitoring and analysis systems easy. This dual output capability suits diverse research and reporting needs.

Q: How is flow measurement managed in the EHA-100?

A: An integrated flow meter automatically measures the exhaust gas flow, ensuring that flow rate data is captured accurately and in real-time during testing, which is critical for precise heat loss calculations.

Q: What is the process for setting up and operating the analyzer?

A: Setup involves connecting the exhaust ports, water cooling system, and power supply. Operation is manual and straightforward thanks to digital displays, flow control valves, and accessible temperature indicators that allow users to monitor and adjust measurement parameters as needed.

Q: What safety and convenience features are included?

A: The system includes a fully insulated body, robust stainless steel construction, accurate temperature controls, and portable design. These features enhance safety, convenience, and accuracy during extended operation and transportation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Internal Combustion Engines Category

Exhaust Gas Analysing Unit

Exhaust Gas Analysing Unit

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Internal Combustion Engines

Power Source : Electric

Feature : Portable, UserFriendly Interface, High Reliability

Weight : 1520 kg (approx)

4 Cylinder Petrol Engine

4 Cylinder Petrol Engine

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Internal Combustion Engines

Power Source : Petrol/Gasoline

Feature : Efficient fuel consumption, smooth operation, robust construction, easy maintenance

Weight : Approx. 110 140 kg (varies by model)

Exhaust Gas Calorimeter

Exhaust Gas Calorimeter

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Internal Combustion Engines

Power Source : 230V AC

Feature : High accuracy measurement, corrosion resistant

Weight : 7 kg

Exhaust Gas Analyzing Unit

Exhaust Gas Analyzing Unit

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Source : Electric



Back to top