trusted seller
Thermo Gravimetric Analyzer (Tga)

Thermo Gravimetric Analyzer (Tga)

Product Details:

X

Thermo Gravimetric Analyzer (Tga) Price And Quantity

Thermo Gravimetric Analyzer (Tga) Trade Information

  • Cash Advance (CA) Cash in Advance (CID) Cheque Telegraphic Transfer (T/T) Letter of Credit (L/C)
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • carton box, export quality also available
  • Asia Middle East Africa
  • All India
  • ISO 9001, 14001 ,CE

Product Description

Thermo Gravimetric Analyzer (Tga)
  • Temperature range:-150°C to 2400°C
  • Furnace:Variety of furnaces incl. high-speed, water-vapor, low to
  • Highest temperature, e.g., silver, platinum, tungsten, etc.
  • Motorized furnace hoist:Double hoist for two furnaces or one furnace + automatic
  • Sample changer
  • Heating rate:0.001 to 50 K/min (furnace-dependent)
  • High-speed furnace:up to 1000 K/min
  • Sensors:TGA, TGA-DTA, TGA-DSC, TGA-DSCcp, special sensors for
  • Hanging samples. Sensors can be changed out easily in a matter of moments
  • Vacuum-tight:10-4 mbar
  • AutoVac:Option for software-controlled automatic evacuation
  • Evacuation system:Options for one and two furnaces; manual or software
  • Controlled operation
  • Atmospheres:Inert, oxidizing, static, dynamic, vacuum
  • Oxygen trap system (OTS®):Optional
  • Automatic sample changer (ASC):20 crucible positions (optional)
  • Gas flow control:Integrated frits (optional 3 mass flow controllers)
  • Temperature resolution:0.001 K
  • Balance resolution:0.1 g (over the entire weighing range)
  • Balance drift:< 5 g/hour
  • Maximum sample load:35000 mg (incl. crucible), corresponds to TGA measuring range
  • Sample volume (max.):TGA: up to 5 ml
  • DSC: 0.19 ml
  • DTA: 0.9 ml
  • DSC enthalpy accuracy:±2% (for most materials)
  • Evolved gas analysis:QMS, GC-MS and/or FT-IR couplings, PulseTA® (options)
  • Optional instrument specialties:Glove box version
  • Corrosion-resistant version
Sensor thermocouple   Temperature range
  • Type E: -150°C to 700°C*
  • Type K: -150°C to 800°C*
  • Type S:RT to 1650°C
  • Type S protected:RT to1650°C
  • Type P:-150°C to 1000°C
  • Type B:RT to 1750°C
  • Type W:RT to 2400°C
Sensor types     Atmospheres
  • TGA-DTA, TGA-DSC (cp):inert, red., oxid., vac.
  • TGA-DTA, TGA-DSC (cp):inert, red., oxid., vac.
  • TGA, TGA-DTA, TGA-DSC(cp)inert, red., oxid., vac.
  • TGA, TGA-DTA:inert, red., oxid., vac., corr.
  • TGA, TGA-DSC, TGA-DSC (cp) inert, red., oxid., vac.
  • TGA, TGA-DTA, TGA-DSC: inert, red., oxid., vac.
  • TGA, TGA-DTA:inert, red., vac.

Enter Buying Requirement Details