trusted seller
Rapid  Extractor
Rapid  Extractor

Rapid Extractor

MOQ : 1 Piece

Rapid Extractor Specification

  • Max Height
  • Approx. 50 cm
  • Temperature
  • Ambient to 60C
  • Automation Grade
  • Manual
  • Accuracy
  • High chemical extraction accuracy for laboratory purposes
  • Features
  • Quick extraction process, corrosion-resistant, easy-clean setup
  • Mounting Type
  • Bench-top/portable
  • Port Size
  • Standard Laboratory Fittings
  • Operating Voltage
  • 230V
  • Specimen Size
  • Standard Laboratory Sample
  • Frequency
  • 50 Hz
  • Usage
  • Chemical Engineering Laboratory Equipments
  • Equipment Type
  • Rapid Extractor
  • Humidity
  • Ambient
  • Application
  • Chemical Engineering Laboratory Equipments
  • Number of Specimens
  • 1
  • Power Supply
  • 230V AC, 50 Hz
  • Product Type
  • Rapid Extractor
  • Capacity
  • 400 ml per run (approx.)
  • Machine Weight
  • Approx. 10-15 kg
  • Control Mode
  • Manual
  • Body Material
  • Borosilicate Glass and Stainless Steel
  • Corrosion Resistance
  • Yes
  • Cleaning Method
  • Detachable parts for ease of cleaning
  • Sample Chamber Capacity
  • Up to 400 ml
  • Safety Features
  • Pressure release valve, anti-corrosive fittings
  • Solvent Compatibility
  • Compatible with most organic solvents
  • Extraction Vessel Material
  • Stainless Steel
  • Suitable For
  • Solid-liquid extraction, fat determination, residue analysis
  • Extraction Time
  • 10-30 minutes depending on sample
 

Rapid Extractor Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Rapid Extractor

Rapid  Extractor

Laboratory Scale Rapid Extractor is used to extract the active constituents from materials in laboratory scale batch sizes.

The Microteknik uses high pressure and extraction phases to achieve a rapid extraction of the active materials with minimum degradation to the product.



Robust Materials for Reliable Operation

Combining borosilicate glass with stainless steel, the Rapid Extractor offers excellent durability and chemical resistance, ensuring long-lasting performance in demanding laboratory environments. The anti-corrosive fittings further enhance longevity, making it ideal for heavy usage with various organic solvents.


Fast and Accurate Extraction Processes

This extractor delivers high-precision results in just 1030 minutes, optimizing laboratory workflows for tasks like fat determination and residue analysis. Its 400 ml sample chamber supports a substantial volume per run, accommodating standard laboratory specimens with ease.


Designed for Safety and Easy Maintenance

Key safety features such as a pressure release valve minimize risks during operation. The extractors detachable parts make cleaning straightforward, supporting consistent performance and compliance with laboratory hygiene standards.

FAQs of Rapid Extractor:


Q: How do I operate the Rapid Extractor for solid-liquid extraction?

A: To operate the Rapid Extractor, simply load your standard laboratory sample into the stainless steel extraction vessel, add the desired organic solvent, and initiate the manual extraction process. The device is compatible with most organic solvents and runs at 230V AC, 50 Hz.

Q: What types of samples and solvents can be used with this extractor?

A: The Rapid Extractor is suitable for standard laboratory specimens intended for solid-liquid extraction, fat determination, or residue analysis. It is compatible with most organic solvents, thanks to its corrosion-resistant stainless steel and borosilicate glass construction.

Q: When is the best time to use the extractor during laboratory analyses?

A: The extractor is ideal for use during procedures requiring rapid and precise solid-liquid extraction, particularly in stages of fat determination or residue analysis where high accuracy and replicability are crucial.

Q: Where should the Rapid Extractor be installed in the laboratory?

A: Designed as a bench-top or portable unit, the extractor can be placed on any stable laboratory surface near a power supply (230V AC) with adequate ventilation and ambient temperature and humidity control.

Q: What is the cleaning process for maintaining the extractor?

A: After use, the extractors detachable parts can be easily removed for thorough cleaning. Rinse all components with compatible cleaning agents, ensuring all residues are removed to maintain consistent performance and chemical compatibility.

Q: What are the main benefits of using this equipment in chemical labs?

A: Key benefits include rapid and accurate extraction times, excellent corrosion resistance, ease of cleaning, and safety integrated design. These features enhance laboratory efficiency, safety, and result reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Chemical Engineering Laboratory Equipments Category

Reverse Osmasis Ultra Filteration Unit

Reverse Osmasis Ultra Filteration Unit

Minimum Order Quantity : 1 Piece

Usage : Industrial

Material : Mild Steel

Power Supply : Electric

EMULSION POLYMERIZATION SET-UP APPARATUS

EMULSION POLYMERIZATION SET-UP APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Laboratory Equipments

Material : Mild Steel

Power Supply : Electric

Quartz Water Distillation Apparatus

Quartz Water Distillation Apparatus

Minimum Order Quantity : 1 Piece

Usage : Industrial

Material : Mild Steel

Power Supply : Electric

LIQUID PHASE CHEMICAL REACTOR APPARATUS

LIQUID PHASE CHEMICAL REACTOR APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Chemical Engineering Laboratory Equipments

Product Type : LIQUID PHASE CHEMICAL REACTOR APPARATUS

Application : Chemical Engineering Laboratory Equipments



Back to top