trusted seller
Pensky Marten Flash Point Apparatus for Bitumen Testing
Pensky Marten Flash Point Apparatus for Bitumen Testing

Pensky Marten Flash Point Apparatus for Bitumen Testing

MOQ : 1 , , Piece

Pensky Marten Flash Point Apparatus for Bitumen Testing Specification

  • Accuracy
  • ± 1°C
  • Display Type
  • Analog dial thermometer or Digital
  • Port Size
  • Standard
  • Test Range
  • Up to 400°C
  • Temperature
  • Ambient to 400°C
  • Features
  • Stainless steel cup, insulated handle, flame application mechanism
  • Power Supply
  • 230 V AC, 50 Hz
  • Response Time
  • < 10 seconds
  • Number of Specimens
  • Single specimen per test
  • Mounting Type
  • Table Top
  • Humidity
  • 0-95% RH, non-condensing
  • Automation Grade
  • Manual
  • Gas Pressure
  • Regulated (as per IS standards)
  • Max Height
  • Approx. 35 cm
  • Operating Voltage
  • 230 V AC
  • Application
  • bb
  • Usage
  • Bitumen Testing Instruments
  • Product Type
  • Pensky Marten Flash Point Apparatusus
  • Interface Type
  • Manual
  • Specimen Size
  • 75 ml (cup capacity)
  • Frequency
  • 50 Hz
  • Measuring Range
  • Ambient to 400°C
  • Resolution
  • 0.1°C
  • Capacity
  • Up to 400°C (Test Temperature Cap.)
  • Machine Weight
  • Approx. 6-8 kg
  • Test Speed
  • Manual
  • Test Width
  • Standard cup diameter: 55 mm
  • Control Mode
  • Manual Operation
  • Cup Cover Material
  • Brass
  • Calibration
  • Supplied with calibration certificate (if required)
  • Conformity
  • IS 1209, ASTM D93, IP 34
  • Cup Material
  • Brass/Stainless Steel
  • Test Flame Source
  • Gas test jet burner
  • Safety
  • Fitted with heat resistant handle and flame shutter
  • Standard Accessories
  • Thermometer, Gas cock, Stirrer, Flame Applicator
  • Temperature Control
  • Adjustable
  • Ignition Type
  • Manual flame
  • Sample Volume
  • 60-75 ml
  • Heating Arrangement
  • Electrical heating with energy regulator
  • Equipment Type
  • Pensky Marten Flash Point Apparatus
 

Pensky Marten Flash Point Apparatus for Bitumen Testing Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

Pensky Marten Flash Point Apparatus for Bitumen Testing About

Pensky Marten Flash Point Apparatus :

Introduction    


This is widely used for determination for closed cup Flash Point of Fuel Oil, cut back asphalts, other viscous material and suspension of solids having a flash point above 490C (1200F).


General Descripation & Specifications    


Flash & Fire Point Apparatus / Pensky-Martens Apparatus For determining the flash point of fuel oils and lubricating oil, bitumen other than cutback bitumen and suspension of solids in liquid, having a flash point above 49C.

The oil cup is made of brass, fitted with a thermally insulated lifting handle. The cup lid, with insulated handle, is fitted with two opposite wedge cams, which engage under pillars secured to the cup flange. This feature facilitates easy removal of the lid by rotating the handle a few degrees to disengage the cams. The shutter opening mechanism is designed for smooth operation and is operated by a spring handle with a knuled knob. A flame exposure device (Gas test jet assembly) is mounted over the lid. The manually operated stirrer has flexible has a flexible shaft. The cup assembly is positioned in a cast iron air bath, fitted with a chrome plated brass top. The air bath is mounted on an upright which serves as a gas manifold. Valve controlled supply lines for adjustable flames are provided with pilot and test flames. An additional line with control valve supplies gas for use with open flash clip, in accordance with IS: 1448 (P: 66), IS: 1209, A ring support is provided for the lid when not in use. Electrical heating, with gas test jet and electric heater with energy regulator. 220V, 50 Hz, Single Phase, AC 


Optional Accessories    
The following accessories are not part of the standard supply and supplied at an extra cost.
Open clip for converting Close model to open cup test model as per.
Low Range (-7-1100C x 0.50C) thermometer
High Range (900C " 3700C x 20C) thermometer
Electric FHP motor with stirrer (in place of hand stirring)
Voltage varrier temp. controller with digital temperature indicator.



Robust Construction & User-Friendly Design

With its table-top mounting, brass or stainless steel components, heat insulation, and safety mechanisms, this apparatus promises long-term durability and operator safety. Its manual operation with adjustable temperature control allows for tailored testing, supported by an analog or digital thermometer with quick response.


Precision Measurement for Bitumen Testing

The apparatus can measure flash points from ambient temperature up to 400C with an accuracy of 1C and resolution of 0.1C. The manual test flame application ensures compliance with key standards, while the regulated gas burner and energy regulator provide stable testing conditions for consistent results.

FAQs of Pensky Marten Flash Point Apparatus for Bitumen Testing:


Q: How is the Pensky Marten Flash Point Apparatus used in bitumen testing?

A: The apparatus is utilized to determine the flash point of bitumen by heating a sample (6075 ml) in the brass or stainless steel cup, applying a test flame manually at regular intervals, and noting the temperature at which a flash is first observed. It complies with IS 1209, ASTM D93, and IP 34 test methods.

Q: What are the main benefits of this apparatus for bitumen testing labs?

A: The instrument offers high measurement accuracy (1C), robust construction, safety features like the heat-resistant handle and flame shutter, and conformity with major testing standards. Its manual control provides flexibility while the calibration certificate ensures traceability and reliability.

Q: When should calibration be requested for the apparatus?

A: Calibration should be requested when accurate temperature measurement is critical, during initial setup, after a set period of regular use, or as outlined by your laboratorys quality assurance procedures. An optional calibration certificate is available upon order.

Q: Where can the Pensky Marten Flash Point Apparatus be installed?

A: The apparatus is suited for laboratory environments and industrial testing rooms. Its tabletop design with compact dimensions (max. height approx. 35 cm) allows it to fit on standard workbenches and provides easy manual operation.

Q: What is the process for performing a flash point test with this equipment?

A: The process involves placing a measured bitumen sample (up to 75 ml) in the test cup, heating it with the regulated electrical system, stirring as required, and applying a manual test flame at preset intervals until a flash is observed. The precise temperature is then recorded via the provided thermometer.

Q: Can the apparatus be used with both analog and digital thermometers?

A: Yes, the apparatus supports either analog dial thermometers or digital models for temperature readings, each featuring rapid response times (<10 seconds) and fine resolution (0.1C).

Q: What safety measures are included during operation?

A: The design incorporates a heat-resistant handle for safe handling of the cup, a flame shutter to minimize accidental exposure, and a flame application mechanism to precisely control ignitionall contributing to operator safety during high-temperature testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Bitumen Testing Instruments Category

Distillation for Cut Back Bitumen

Distillation for Cut Back Bitumen

Minimum Order Quantity : 1 , , Piece

Usage : Bitumen Testing Instruments

Application : Bitumen Testing Instruments

Product Type : Distillation for Cut Back Bitumen

Machine Weight : Approx. 20 kg

Control Mode : Manual / SemiAutomatic

Kinematic Viscosity Bath

Kinematic Viscosity Bath

Minimum Order Quantity : 1 Piece

Usage : Bitumen Testing Instruments

Application : Bitumen Testing Instruments

Product Type : Kinematic Viscosity Bath

Machine Weight : Approx. 35 kg

Control Mode : Digital PID temperature controller

Thin Film Oven and Loss on Heating Oven

Thin Film Oven and Loss on Heating Oven

Minimum Order Quantity : 1 , , Piece

Usage : Bitumen Testing Instruments

Application : Bitumen Testing Instruments

Product Type : Thin Film Oven and Loss on Heating Oven

Machine Weight : 45 kg (approx.)

Control Mode : Digital Temperature Controller

Rolling Thin Film Oven

Rolling Thin Film Oven

Minimum Order Quantity : 1 , , Unit

Usage : Bitumen Testing Instruments

Application : Bitumen Testing Instruments

Product Type : Rolling Thin Film Oven

Machine Weight : Approx. 50 kg

Control Mode : Digital Temperature Controller



Back to top