trusted seller
Electro Convulsometer
Electro Convulsometer

Electro Convulsometer

MOQ : 1 Piece

Electro Convulsometer Specification

  • Application
  • Pharmaceutical Lab Equipment
  • Model No
  • EC-250
  • Core Components
  • Electronics, Electrodes, Cables
  • Measurement Range
  • 0 to 300 mA
  • Accuracy
  • 1%
  • Product Type
  • Electro Convulsometer
  • Power Source
  • Electric
  • Automation Grade
  • Semi-Automatic
  • Voltage
  • 220 V AC
  • Temperature Range
  • Ambient to 45C
  • Usage
  • Pharmaceutical Lab Equipment
  • Frequency
  • 50 Hz
  • Feature
  • Accurate Output, Low Power Consumption, User-Friendly Interface
  • Capacity
  • 1 Sample per Operation
  • Equipment Materials
  • Mild Steel Powder Coated
  • Type
  • Electro Convulsometer
  • Display Type
  • LED Digital Display
  • Dimension (L*W*H)
  • 250 x 200 x 140 mm
  • Weight
  • Approx 4 Kg
  • Pulse Duration
  • 0.1 - 1.0 sec
  • Timer
  • Up to 10 sec, digital
  • Output Current Range
  • 0 to 300 mA, adjustable
  • Stimulation Mode
  • Manual and Timer
  • Safety
  • Overload Protection
  • Isolation
  • Output Isolated from Mains
  • Construction
  • Portable Compact Design
  • Accessories
  • Electrode Set, Power Cable, User Manual
 

Electro Convulsometer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Electro Convulsometer

Electro Convulsometer :

Electro Convulsometer: The instrument provides 50 Hz stimulus current which can be adjusted 0.15 mA to 330 mA in discrete steps for producing minimal and supra maximal seizures required in the assaying of anti-epileptic and anti convulsant drugs. The application of stimulus current can be controlled by an electronic timer from 0.1 second to 1 second in steps of 0.1 to 3 seconds in 11 steps. An L.E.D. indicates the duration of stimulus.



Versatile Adjustable Output for Precision

The EC-250 Electro Convulsometer offers a flexible current range of 0 to 300 mA and pulse durations adjustable from 0.1 to 1.0 seconds. This level of control allows researchers to precisely tailor test parameters for diverse experimental protocols, ensuring consistent and reproducible results for laboratory studies in the pharmaceutical sector.


User-Friendly and Safe Operation

Engineered with a focus on user safety and convenience, the EC-250 incorporates an isolated output design to eliminate mains interference and overload protection for enhanced operational security. The intuitive LED digital display clearly presents operating values, while the user manual guides proper usage for optimal performance and equipment longevity.


Compact and Robust Construction

Designed with portability in mind, the Electro Convulsometer features a compact build, weighing approximately 4 kg and constructed from mild steel with a resilient powder-coated finish. Its sturdy design makes it suitable for both mobile and stationary lab setups, providing durability and ease of maintenance.

FAQs of Electro Convulsometer:


Q: How does the output current adjustment function in the Electro Convulsometer EC-250?

A: The EC-250 allows precise control of the output current, adjustable from 0 to 300 mA. Users can set the desired current using the user-friendly interface, ensuring accurate delivery based on experimental requirements.

Q: What are the main benefits of using this convulsometer in pharmaceutical laboratories?

A: This device offers high accuracy (1%), reliable overload protection, and adjustable parameters, making it ideal for controlled, reproducible tests. Its compact portable design and clear digital display enhance user convenience and system reliability.

Q: When should the timer mode be selected over manual stimulation?

A: Timer mode is preferable when predetermined, consistent stimulus durations are required, as it offers adjustable pulse durations up to 10 seconds, ideal for standardizing experimental protocols, while manual mode suits applications requiring user-controlled timing.

Q: Where can this Electro Convulsometer be used effectively?

A: The EC-250 is best suited for pharmaceutical laboratories engaged in research and experimental studies, but its robust construction and portable design also make it practical for university and clinical lab environments.

Q: What materials are used in the construction of the EC-250?

A: The main body is built from mild steel with powder coating, which provides strength, corrosion resistance, and longevity, making the equipment suitable for rigorous laboratory use.

Q: How is user safety ensured while operating this instrument?

A: Safety is prioritized through output isolation from mains to prevent electrical hazards and built-in overload protection to safeguard both the user and the device during prolonged laboratory use.

Q: What process steps are involved in operating the EC-250?

A: To operate, connect the electrode set and power cable, set the desired current and pulse duration using the controls, select the stimulation mode (manual or timer), and monitor parameters via the LED display. The user manual provides step-by-step guidance for secure, effective operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Lab Equipment Category

Filtration Unit

Filtration Unit

Minimum Order Quantity : 1 , , Piece

Usage : Pharmaceutical Lab Equipment

Dimension (L*W*H) : 500mm x 350mm x 900mm (varies by model)

Equipment Materials : Stainless Steel 304/316, Borosilicate Glass, PTFE Seals

Weight : 2040 kg (approximate, depends on model)

Automation Grade : Manual & SemiAutomatic options available

Conical Percolator

Conical Percolator

Minimum Order Quantity : 1 Piece

Usage : Pharmaceutical Lab Equipment

Dimension (L*W*H) : Varies with capacity, sample size: 180mm x 180mm x 450mm

Equipment Materials : High quality borosilicate glass / Stainless Steel

Weight : Depends on capacity; approx. 18 kg

Automation Grade : Manual

Tablet Coating Pan

Tablet Coating Pan

Minimum Order Quantity : 1 , , Piece

Usage : Tablet Coating Pan

Dimension (L*W*H) : 900 x 500 x 1100 mm

Equipment Materials : Stainless Steel (SS 304/316)

Weight : Appx. 150 Kg

Automation Grade : SemiAutomatic

Rabbit Holder

Rabbit Holder

Minimum Order Quantity : 1 , , Piece

Usage : Pharmaceutical Lab Equipment

Dimension (L*W*H) : Approx. 45 cm x 20 cm x 20 cm

Equipment Materials : Stainless Steel

Weight : Approx. 23 kg

Automation Grade : Manual



Back to top