trusted seller
Compressible Flow Unit
Compressible Flow Unit

Compressible Flow Unit

MOQ : 1 Unit

Compressible Flow Unit Specification

  • Temperature
  • Ambient to 50C
  • Response Time
  • 1 second
  • Usage
  • Fluid Machines Equipments
  • Power Supply
  • 230V AC, 50 Hz
  • Frequency
  • 50 Hz
  • Humidity
  • Up to 85% RH
  • Number of Specimens
  • One test section at a time
  • Operating Voltage
  • 230V AC
  • Resolution
  • 0.01 L/min
  • Mounting Type
  • Bench-top
  • Port Size
  • 1/4 BSP
  • Accuracy
  • 1% F.S.
  • Max Height
  • 600 mm
  • Measuring Range
  • 0.5 to 15 L/min (Air)
  • Specimen Size
  • Standard test section
  • Automation Grade
  • Semi-automatic
  • Application
  • Fluid Machines Equipments
  • Features
  • Visual flow observation, interchangeable test sections, accurate measurements, durable build
  • Display Type
  • Digital/Analog gauge
  • Test Range
  • Compressible flow regimes
  • Interface Type
  • Manual/optional digital output
  • Product Type
  • Compressible Flow Unit
  • Gas Pressure
  • Up to 2 Bar
  • Capacity
  • Up to 20 L/min
  • Machine Weight
  • Approx. 45 kg
  • Control Mode
  • Manual / Digital
  • Overall Dimensions
  • 800 x 450 x 600 mm (L x W x H)
  • Safety
  • Pressure relief valve, overload protection
  • Data Output
  • Optional USB data interface
  • Compliance
  • Meets general laboratory safety standards
  • Test Section Type
  • Convergent-divergent nozzle (optional interchangeable sections)
  • Equipment Type
  • Compressible Flow Unit
  • Pressure Measurement
  • Mercury manometer / Digital sensor
  • Material
  • Mild steel frame with powder coating, acrylic test section
  • Flowmeter Type
  • Rotameter / Digital flowmeter
  • Pump Type
  • Inbuilt centrifugal/blower pump
  • Accessories
  • Set of connecting pipes, manometer fluid, instruction manual
 

Compressible Flow Unit Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Compressible Flow Unit

Compressible Flow Unit MTFM-14


The single-stage compressor is driven by an integral three-phase AC motor. The compressor speed can be varied using an advanced torque-vector frequency inverter which gives stable and accurate speed control plus direct electronic read-out of the torque produced by the motor. The compressor is fitted with an outlet duct incorporating a throttling valve which allows the flow to be varied independent from compressor speed.


The equipment is supplied with a convergent-divergent test section fitted at the compressor inlet designed to produce Mach-1 velocity at the throat. The duct is fabricated from clear acrylic enabling the student to see the construction and the profiles. A pressure-sensing ring tapping is provided at the inlet, at the throat and at the discharge end of the diffuser. This duct allows all the major concepts of compressible flow to be demonstrated.


The electronics console includes two high-range and two low-range differential pressure sensors plus a control for motor speed and displays for the compressor speed, the pressures and the motor torque.

FEATURES

  • Variable-speed air compressor with accurate electronic speed control
  • Electronic pressure sensors
  • Standard unit includes convergent-divergent duct designed to produce Mach 1 velocity at the throat
  • Data logging option available
  • Lower speed operation
  • Integral motor with direct drive
  • Reduced operating noise
  • Reduced vibration levels

TECHNICAL SPECIFICATIONS

  • A bench top unit designed to demonstrate and teach the fundamentals of compressible flow to engineering students
  • Fitted with a single-stage, side-channel blower
  • Complete with convergent-divergent duct capable of achieving Mach 1 velocity at the throat
  • Advanced torque-vector speed control of blower motor with electronic torque measurement
  • Four electronic pressure sensors
  • Test section made from clear acrylic
  • Additional test sections available (6 off) complete with bench top stand
  • Compressor test accessory available
  • Data logging accessory available, complete with educational software and electronic temperature sensors
  • Compressor speed : 3,300 rpm (max)
  • Stages : 1
  • Motor Power : 55 kW
  • Sensors: +/- 103.4 kPa 1 off



Versatile Test Section

The Compressible Flow Unit is equipped with a transparent acrylic test section, allowing users to visually observe a wide range of compressible flow phenomena. Interchangeable convergent-divergent nozzles provide flexibility for experimenting with different flow regimes, supporting various research and teaching applications.


Advanced Measurement Features

With options for rotameter or digital flowmeter, as well as mercury or digital manometer for pressure measurement, the unit ensures high accuracy and swift response timesup to 1% F.S. and a 1-second display interval. Digital/analog gauges make real-time monitoring straightforward for research or instructional use.


Enhanced Safety and Durability

Safety is built into the design, with pressure relief valves and overload protection mechanisms. The mild steel frame features a durable powder coating, making the unit robust and reliable for frequent laboratory use while meeting general laboratory safety standards.

FAQs of Compressible Flow Unit:


Q: How does the Compressible Flow Unit facilitate visual observation of fluid flow?

A: The unit features a transparent acrylic test section, enabling users to observe compressible flow patterns, pressure changes, and nozzle effects directly during operation. This visual accessibility enhances both learning and experimental accuracy.

Q: What types of test sections can be used with this apparatus?

A: The Compressible Flow Unit supports an optional range of interchangeable convergent-divergent nozzle test sections, allowing users to investigate various compressible flow regimes and tailor experiments according to specific research or curriculum requirements.

Q: When is the USB data interface recommended for use?

A: The optional USB data interface is beneficial when digital data logging or remote monitoring is required. It provides seamless integration with computers for more detailed analysis and record keeping, especially in advanced lab experiments or reports.

Q: Where should this equipment be installed for optimal use?

A: Designed as a bench-top unit with compact overall dimensions (800 x 450 x 600 mm), the Compressible Flow Unit is best installed in laboratory environments where access to a stable 230V AC power supply and adequate ventilation are ensured.

Q: What safety measures are incorporated in this unit?

A: The system includes a pressure relief valve and overload protection to prevent unsafe conditions during high-pressure flow experiments. These features comply with general laboratory safety standards, ensuring a safe working environment for users.

Q: How is accurate measurement ensured during experiments?

A: The apparatus uses precise rotameter/digital flowmeters and mercury/digital pressure sensors, delivering a measuring range from 0.5 to 15 L/min with 1% F.S. accuracy and 0.01 L/min resolution. Fast response times (1 second) enable reliable, real-time data collection.

Q: What are the main benefits of using the Compressible Flow Unit in laboratory settings?

A: Benefits include durable construction, high measurement accuracy, visual flow analysis, flexible test section setup, and enhanced safetyall of which make it an ideal choice for fluid machines research, instruction, and industrial application.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Flow Channel

Flow Channel

Minimum Order Quantity : 1 Piece

Usage : Fluid Machines Equipments

Product Type : Flow Channel

Application : Fluid Machines Equipments

Accuracy : 1%

Mounting Type : Bench Mounted

Computerised Flow Meter Caliberation Equipment

Computerised Flow Meter Caliberation Equipment

Minimum Order Quantity : 1 Piece

Usage : Fluid Machines Equipments

Product Type : Computerised Flow Meter Caliberation Equipment

Application : Fluid Machines Equipments

Accuracy : 0.5% of reading

Mounting Type : Table Top / Floor Standing

Fluid Dynamics Laboratory Tools

Fluid Dynamics Laboratory Tools

Minimum Order Quantity : 1 , , Piece

Usage : Fluid Machines Equipments

Product Type : Fluid Mechanics Lab Equipments

Application : Fluid Machines Equipments

Accuracy : 1% of FSD

Mounting Type : Bench top

Vernier Hook and Point Gauge

Vernier Hook and Point Gauge

Minimum Order Quantity : 1 Unit

Usage : Fluid Machines Equipments

Product Type : Vernier Hook and Point Gauge

Application : Fluid Machines Equipments

Accuracy : 0.02 mm

Mounting Type : Bench/Table mountable



Back to top