Air Flow Studies Apparatus Specification

  • Frequency
  • 50 Hz
  • Power Supply
  • 230V AC, 50Hz, Single Phase
  • Application
  • Fluid Machines Equipments
  • Features
  • Portable, Transparent Test Section, Variable Orifice, Interchangeable Test Models
  • Resolution
  • 0.01 m/min
  • Interface Type
  • LCD/Analog meter
  • Automation Grade
  • Semi-Automatic
  • Product Type
  • Air Flow Studies Apparatus
  • Operating Voltage
  • 230V AC
  • Usage
  • Fluid Machines Equipments
  • Humidity
  • Up to 95% RH (Non-condensing)
  • Display Type
  • Digital
  • Port Size
  • 50 mm
  • Mounting Type
  • Table Top
  • Gas Pressure
  • 0-2 bar
  • Test Range
  • 0.2-5 m/min
  • Temperature
  • 5C to 50C
  • Hardness
  • Mild Steel Powder Coated, Acrylic Section
  • Response Time
  • < 2 seconds
  • Specimen Size
  • 100 mm x 100 mm
  • Max Height
  • 500 mm
  • Number of Specimens
  • 1
  • Measuring Range
  • 0.2 to 10 m/min
  • Accuracy
  • 1% of full scale
  • Capacity
  • 2-10 LPM
  • Machine Weight
  • Approx. 25 kg
  • Test Speed
  • 0.2 to 2.0 m/s
  • Test Width
  • 150 mm
  • Test Stroke
  • 0-500 mm
  • Control Mode
  • Manual/Automatic
 

Air Flow Studies Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA), Telegraphic Transfer (T/T), Letter of Credit (L/C), Cash in Advance (CID), Cheque
  • Supply Ability
  • 100 Units, , Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Air Flow Studies Apparatus

Air Flow Studies: MTFM-06


The equipment comprises a long smooth walled pipe connected to the suction side of an electrically driven centrifugal fan. The fan discharge pipe terminates in a flow-control damper for closed-conduit work or a plate containing a small aperture for jet dispersion measurements. Air enters the smooth walled pipe through one of the two flow-measurement nozzles provided.


Pressure tapings along the length of the pipe permit the pressure gradient to be determined. A bend or mitered cascade elbow may be fitted midway along the smooth wall pipe for comparison of pressure losses. Boundary layer growth is determined by the measurement of the velocity profile at five stations along the pipe using a traversing Piton tube.


A conventional flow-measuring orifice plate is supplied for installing in the pipe upstream of the fan for additional demonstrations of pressure loss and recovery. Air-jet studies are carried out on the discharge side of the fan. A Piton tube is traversed vertically and horizontally at different distances from the discharge orifice to investigate the dispersion properties. The equipment is mounted on a floor-standing steel frame with an adjacent support for the extended suction pipe. Pressure measurements are made on a multi-tube inclinable manometer mounted on the support frame.


FEATURES


  • Alternative bends and bell mouth
  • Orifice plate
  • Piton traverse
  • Jet
  • Jet traverse Piton assembly


DEMONSTRATION CAPABILITIES


Practical demonstration of the quantitative flows in geometry described in the laws of conservation of mass and momentum

Using manometers to measure pressure drop

Using a Piton-static tube to measure flow

Employing nozzles and orifices to measure flow

Understanding and measuring velocity profiles

Relating pressure loss in a duct to flow rate

Measuring the flow resistance of duct fittings

Understanding the use of Reynolds numbers

Measuring the dispersion of a jet


TECHNICAL SPECIFICATIONS


  • Centrifugal fan capacity: 218 l/s at STP
  • Pipe velocity range: 0-35 m/s
  • Inlet pipe: dia. 80 mm
  • length: 2.75 m
  • Interchangeable nozzles: dia. 50 mm and 80 mm
  • Internal pipe orifice: dia. 50 mm
  • Jet discharge pipe orifice: dia. 30 mm
  • Manometer range: 0-283 mm H2O
  • Manometer fluid: Kerosene (s.g. 0.78)



Advanced Construction for Reliable Testing

The apparatus is built from mild steel with powder coating and clear acrylic for durability and transparency. Its compact design (700 x 350 x 500 mm), lightweight frame (approx. 25 kg), and portable mounting make it suitable for laboratory and educational environments. Flexible hose couplings and powder-coated materials ensure longevity and easy maintenance, enhancing operational efficiency.


Flexible Measurement and Control Features

Test speeds range from 0.2 to 2.0 m/s, with a test stroke up to 500 mm. Users can switch between manual and automatic control modes, benefiting from a quick response time and a digital display interface. The apparatus supports a wide measuring range (0.2 to 10 m/min) and optional digital data logging for seamless experiment tracking and reporting.


Wide Applicability in Fluid Machines Studies

Designed specifically for fluid machines equipment, the apparatus accommodates diverse air flow studies. Accessoriessuch as interchangeable test models and user manualsenable tailored experimentation. Calibration certificates assure precise results, making the equipment ideal for academic, research, and testing labs.

FAQs of Air Flow Studies Apparatus:


Q: How is the Air Flow Studies Apparatus constructed and what are its main materials?

A: The apparatus is constructed from powder-coated mild steel for strength and durability, with a clear acrylic test section for direct visibility of airflow patterns during experiments.

Q: What is the process for conducting air flow studies with this equipment?

A: To perform a test, set up the specimen in the clear acrylic section, establish connections using flexible hose couplings, select the control mode, and adjust the fan speed. Use the digital interface for real-time data monitoring and, if equipped, log measurements electronically.

Q: When should the optional digital data logger be used?

A: The digital data logger is recommended when frequent data collection or detailed analysis is required, such as in research environments or when creating comprehensive experiment records. It facilitates easy tracking and storage of data over multiple tests.

Q: Where is this Air Flow Studies Apparatus typically utilized?

A: This apparatus is ideal for laboratories, research centers, educational institutions, and quality control departments specializing in fluid machines and airflow analysis.

Q: What are the benefits of using interchangeable test models in experiments?

A: Interchangeable test models increase versatility, allowing different airflow behaviors to be studied under identical operating conditions. This feature supports comparative analysis and broadens the scope of experimentation.

Q: How precise are the measurements obtained from the device?

A: Measurements from the apparatus are highly accurate, with a precision of 1% of full scale and a resolution of 0.01 m/min, ensuring reliable and reproducible results in all test conditions.

Q: What is included with the Air Flow Studies Apparatus upon purchase?

A: Supplied accessories include a set of interchangeable test models, a comprehensive user manual, and a calibration certificate, ensuring readiness for immediate laboratory use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Large Angle Stability System

Large Angle Stability System

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Large angle measurement, stable base, userfriendly interface

Frequency : 50 Hz

Power Supply : 230V AC, 50Hz

Mounting Type : Benchtop

Energy Losses in Bend

Energy Losses in Bend

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Transparent pipes, quick connect valves, corrosionresistant construction

Frequency : 50 Hz

Power Supply : 220 V AC, 50 Hz

Mounting Type : Benchtop

Osborne Reynold Demonstration Apparatus

Osborne Reynold Demonstration Apparatus

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Features : Transparent glass tube, dye injection system

Frequency : 50 Hz

Power Supply : 230V AC, 50Hz

Mounting Type : Benchtop

Fluid Dynamics Laboratory Tools

Fluid Dynamics Laboratory Tools

Price 100 INR / Piece

Minimum Order Quantity : 1 , , Piece

Features : Durable, corrosionresistant, clear observation windows, modular setup

Frequency : 50Hz

Power Supply : 230V AC, 50Hz

Mounting Type : Bench top