trusted seller
Versatile Data Acquisition System
Versatile Data Acquisition System

Versatile Data Acquisition System

MOQ : 1 , , Piece

Versatile Data Acquisition System Specification

  • Test Range
  • Up to 16 Channels Simultaneously
  • Operating Voltage
  • 230 V AC
  • Response Time
  • 1 ms
  • Measuring Range
  • Customizable as per requirement
  • Temperature
  • 0C to 60C
  • Resolution
  • 16 Bit
  • Interface Type
  • USB, RS-232, Ethernet
  • Automation Grade
  • Automatic
  • Application
  • Civil Engineering Lab Equipments
  • Port Size
  • Multiple Data Channels
  • Frequency
  • 50 Hz
  • Features
  • Multi-channel, Modular, User Friendly, Data Logging, Compatible With PC
  • Display Type
  • Digital/LCD Display
  • Accuracy
  • 0.1% FSR
  • Product Type
  • Versatile Data Acquisition System
  • Equipment Type
  • Versatile Data Acquisition System
  • Mounting Type
  • Portable / Rack Mounted
  • Humidity
  • Up to 95% RH (Non-condensing)
  • Power Supply
  • 230 V AC, 50 Hz
  • Usage
  • Civil Engineering Lab Equipments
  • Capacity
  • Depends on DAQ Configuration
  • Control Mode
  • Automatic/Manual
 

Versatile Data Acquisition System Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Versatile Data Acquisition System

Versatile Data Acquisition System
Description :

Versatile Data Acquisition System Offered Comes Supported By Sampling Box, Sensors And Computer And Are Interconnected Through Wire. Finding Use In Lab Working Environment, The Product Allows Connection With Different Sampling Boxes. Some Of Its Features Include Providing For Accurate And Reliable Operations, Digital Interface, Portable Size Finish, Allows For Easy Installation, Allows For Independent Working Support, Compatible With Existing Computer And Operating System.



Comprehensive Input Compatibility

This system supports a wide spectrum of sensor types, including voltage, current, thermocouples, RTDs, load cells, and LVDTs. Users can configure each of the up to 16 channels to suit specific testing needs, ensuring adaptable operation in various civil engineering environments. Its modular, expandable architecture allows for future upgrades and diverse measurement scenarios, expanding its utility beyond standard laboratory applications.


Advanced Data Logging and Output

Equipped with internal memory and seamless PC backup, this data acquisition system facilitates secure, long-term data storage. Output data can be exported in universally accepted formats like CSV and Excel, or in custom configurations if needed for specialized analysis. The included Windows-based software streamlines real-time monitoring, data management, and report generationempowering users with high-fidelity results and effortless documentation.


Reliability and Safety for Laboratory and Field Use

Housed in a durable, powder-coated metal enclosure, the system is built for both laboratory and field conditions, tolerating temperatures from 0C to 60C and humidity up to 95% RH. With robust electrical protection, audio/visual channel fault alerts, and options for automatic or manual calibration, it ensures maximum system uptime and data reliability during critical experiments or fieldwork.

FAQs of Versatile Data Acquisition System:


Q: How can I expand the number of channels on this data acquisition system?

A: The system is designed to support up to 16 channels natively, with an option to expand as needed. Expansion modules can be added to accommodate additional channels, making the system customizable for larger or more complex experimental setups.

Q: What input types does the system support and how do I configure them?

A: It supports a broad selection of inputs including voltage, current, RTDs, thermocouples, load cells, and LVDTs. Each channel can be individually configured via the Windows-based software, allowing users to select the sensor type and appropriate measurement parameters for their specific test requirements.

Q: When is calibration needed and how is it performed?

A: Calibration should be performed prior to first use, after any major hardware change, or routinely as specified by your quality procedures. The system supports both automatic and manual calibration methods, which can be initiated and managed directly through the included software interface for accuracy assurance.

Q: Where is the data stored and how can I back up or export my test results?

A: Data is initially stored in the systems internal memory and can be seamlessly backed up to a connected PC. Export options include CSV, Excel, and customizable formats, accessible via the user-friendly software, making data transfer, reporting, and analysis convenient.

Q: What safety features are included to protect the system and data?

A: The device features input overvoltage and short-circuit protection for all channels, along with audio/visual alerts for channel faults, ensuring safe operation and minimizing risks of data loss or sensor damage during use.

Q: How can this system benefit civil engineering laboratory applications?

A: Its multi-channel, modular, and user-friendly design allows simultaneous testing on up to 16 channels, streamlining data collection and analysis. Accurate measurements, reliable protection, and seamless data management enhance productivity and data integrity in civil engineering experiments.

Q: What environments is this data acquisition system suitable for?

A: Engineered for both laboratory and field conditions, it operates reliably across a wide temperature range (0C to 60C) and high humidity levels (up to 95% RH, non-condensing), making it suitable for diverse civil engineering testing scenarios.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Civil Engineering Lab Equipments Category

Ductilometer The Elastic Recovery

Ductilometer The Elastic Recovery

Minimum Order Quantity : 1 Unit

Usage : Civil Engineering Lab Equipments

Automation Grade : Automatic

Display Type : LCD Digital Display

Features : Digital control, Automatic stop, Temperature control, Multisample testing

Power Supply : 230V AC, 50 Hz

SHEAR MACHINE

SHEAR MACHINE

Minimum Order Quantity : 1 Piece

Usage : Civil Engineering Lab Equipments

Automation Grade : Automatic

Display Type : Digital LCD

Features : Automatic loading, digital display, data output, programmable test parameters, safety interlocks

Power Supply : 220V AC, 50 Hz

BLAINE FINENESS APPARATUS

BLAINE FINENESS APPARATUS

Minimum Order Quantity : 1 Unit

Usage : Civil Engineering Lab Equipments

Automation Grade : Manual

Display Type : Analogue Manometer (liquid column)

Features : Simple operation, reliable results, IS:4031/ASTM C204 compliant

Power Supply : Not Required (Manual)

Grain Size Chart

Grain Size Chart

Minimum Order Quantity : 1 Piece

Usage : Civil Engineering Lab Equipments

Automation Grade : Manual

Display Type : Printed Laminated Sheet

Features : Laminated surface, Clear grain images, Size reference chart



Back to top