trusted seller
Vacuum Pump
Vacuum Pump

Vacuum Pump

MOQ : 1 , , Unit

Vacuum Pump Specification

  • Gas Pressure
  • Maximum 760 mm Hg
  • Product Type
  • Vacuum Pump
  • Features
  • Continuous operation, corrosion-resistant, oil-lubricated
  • Measuring Range
  • 0-760 mm Hg
  • Frequency
  • 50 Hz
  • Interface Type
  • Pipe Connection
  • Accuracy
  • ± 2 mm Hg
  • Equipment Type
  • Vacuum Pump
  • Display Type
  • Analog
  • Response Time
  • Immediate
  • Resolution
  • 1 mm Hg
  • Operating Voltage
  • 230 V AC
  • Humidity
  • 0-90% RH (Non-condensing)
  • Port Size
  • 6 mm (Standard)
  • Application
  • Bitumen Testing Instruments
  • Test Range
  • 0-760 mm Hg
  • Mounting Type
  • Bench Top
  • Automation Grade
  • Manual
  • Power Supply
  • 230 V AC, 50 Hz
  • Usage
  • Bitumen Testing Instruments
  • Temperature
  • 5°C to 40°C
  • Capacity
  • Laboratory Scale
  • Machine Weight
  • Approx. 8 kg
  • Control Mode
  • Manual
  • Vacuum Creation Time
  • Approx. 30 seconds for 760 mm Hg
  • Inlet/Outlet
  • Single Stage
  • Pump Type
  • Rotary Vane
  • Protection Class
  • IP20
  • Noise Level
  • 60 dB
  • Motor Power
  • 1/4 HP
  • Oil Type
  • Vacuum Pump Oil
  • Material
  • Mild Steel (Powder Coated)
 

Vacuum Pump Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Africa, Middle East, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Vacuum Pump

Vacuum Pump

Features

  • Electrically operated oil free with 1/4 HP motor and moisture trap.
  • High vacuum consist of a metallic casing having Cylindrical bore accommodating an eccentrically mounted slotted rotor bearing, a pair of Vanes in the slots forced a part and pressed against the wall of the casing of the spring.
  • With the rotor these vanes slide along the wall Casing wiping before them the air which has entered the apparatus via the suction orifice.
  • The air is finally forced out of the pump by the Vanes through the oil immersed exhaust valve.
  • The pumps are made in either single or double stages, the pumps are electrically operated.
  • V belts driven and mounted on iron base plates.
  • Experienced and research in the field, strict supervision by trained experts and Quality contact by qualified and experienced engineers valve.
  • The pumps are made in either single or double stages, the pumps are electrically operated.
  • V belts driven and mounted on iron base plates.
  • Experienced and research in the field, strict supervision by trained experts and Quality contact by qualified and experienced engineers ensure that every pump is reliable technically proved to give trouble free along Service.

Technical Specification

  • Max. Vacuum -650 mm Hg = 85.5 kPa = 110 torr
  • Motor Rotation 1450 r.p.m.
  • Max. Power Consumption 60 W
  • Horse Power 1 / 8 Hp
  • Power 220, 240 V, 50 / 60 Hz
  • Oil Capacity 200 ml
  • Intake Fitting 1/4 Flare
  • Stages 2
  • High vacuum consist of a metallic casing having Cylindrical bore accommodating an eccentrically mounted slotted rotor bearing
  • A pair of Vanes in the slots forced a part and pressed against the wall of the casing of the spring.
  • The rotor these vanes slide along the wall Casing wiping before them the air which has entered the apparatus via the suction orifice.
  • The air is finally forced out of the pump by the Vanes through the oil immersed exhaust valve.
  • The pumps are made in either single or double stages, the pumps are electrically operated.



Reliable Performance for Laboratory Needs

Engineered for bitumen testing applications, this rotary vane vacuum pump offers quick vacuum creation and precise pressure control. Its mild steel construction provides robustness and corrosion resistance, while the oil-lubricated mechanism guarantees uninterrupted operation during demanding laboratory procedures. The manual control and immediate response time facilitate accurate testing outcomes.


User-Friendly Design and Safety

With its analog display and straightforward pipe connection interface, the pump ensures ease of use and quick installation. The IP20 protection rating safeguards the equipment in laboratory environments, while continuous operation and bench-top mounting accommodate convenient, safe handling in routine testing workflows.

FAQs of Vacuum Pump:


Q: How does the vacuum pump improve bitumen testing accuracy?

A: The pump provides precise vacuum control with an accuracy of 2 mm Hg and a resolution of 1 mm Hg, ensuring consistent and reliable results for bitumen testing procedures.

Q: What process is involved in operating the vacuum pump?

A: To use the pump, connect it via the standard 6 mm port, switch on the power supply (230 V AC, 50 Hz), manually adjust vacuum levels through the analog display, and monitor the immediate response as the pump achieves the required vacuum within approximately 30 seconds.

Q: When should the vacuum pump oil be replaced?

A: Regular replacement of vacuum pump oil is recommended according to manufacturer guidelines to maintain optimal lubrication, reduce wear, and prolong pump life, especially under continuous operation conditions.

Q: Where is this vacuum pump most effectively utilized?

A: This vacuum pump is designed for laboratory-scale applications, specifically in environments conducting bitumen testing where rapid vacuum creation and reliable performance are essential.

Q: What are the benefits of its mild steel (powder-coated) construction?

A: The powder-coated mild steel housing enhances corrosion resistance, durability, and longevity, making it suitable for laboratory conditions that may experience varying humidity and temperature levels.

Q: How does the protection class IP20 contribute to safety?

A: The IP20 protection class safeguards against accidental contact with electrical components, reducing risks in laboratory settings while ensuring safe operation during bitumen testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Bitumen Testing Instruments Category

Compaction Pedestal

Compaction Pedestal

Minimum Order Quantity : 1 Piece

Usage : Bitumen Testing Instruments

Automation Grade : Manual

Power Supply : 220 V AC, 50 Hz

Display Type : Mechanical scale

Accuracy : 1%

Standard Penetrometer with Brass Cone

Standard Penetrometer with Brass Cone

Minimum Order Quantity : 1 Piece

Usage : Bitumen Testing Instruments

Automation Grade : Manual

Power Supply : 230V AC, 50 Hz

Display Type : Dial Gauge

Accuracy : 0.01 mm

Ring and Ball Apparatus Electrical

Ring and Ball Apparatus Electrical

Minimum Order Quantity : 1 Piece

Usage : Bitumen Testing Instruments

Automation Grade : SemiAutomatic

Power Supply : 230V AC, 50Hz

Display Type : Digital/Analog (Varies by model)

Accuracy : 0.5C

Triple Beam Balance

Triple Beam Balance

Minimum Order Quantity : 1 , , Piece

Usage : Bitumen Testing Instruments

Automation Grade : Manual

Power Supply : None (Manual)

Display Type : Analog Scale

Accuracy : 0.1 g



Back to top