trusted seller
PHOTO CELL CHARACTERISTICS APPARATUS
PHOTO CELL CHARACTERISTICS APPARATUS
PHOTO CELL CHARACTERISTICS APPARATUS
PHOTO CELL CHARACTERISTICS APPARATUS
PHOTO CELL CHARACTERISTICS APPARATUS
PHOTO CELL CHARACTERISTICS APPARATUS

PHOTO CELL CHARACTERISTICS APPARATUS

MOQ : 1 Piece

PHOTO CELL CHARACTERISTICS APPARATUS Specification

  • Features
  • Adjustable Light Source, Easily Replaceable Photocell
  • Usage
  • Photo Cell Characteristics Apparatus
  • Specimen Size
  • Standard Photocell Size
  • Max Height
  • Approx. 20 cm
  • Test Range
  • 0 - 50 V (Variable)
  • Operating Voltage
  • 230V AC
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Humidity
  • Up to 85% RH (Non-condensing)
  • Accuracy
  • 2%
  • Display Type
  • Analog Meter
  • Power Supply
  • 230V AC, 50Hz
  • Measuring Range
  • Current: 0-200 A, Voltage: 0-50 V
  • Response Time
  • <1 Second
  • Number of Specimens
  • Single Photocell
  • Product Type
  • Photo Cell Characteristics Apparatus
  • Equipment Type
  • Photo Cell Characteristics Apparatus
  • Application
  • Photo Cell Characteristics Apparatus
  • Temperature
  • 0C to 50C Operating
  • Interface Type
  • Direct Panel Interface
  • Resolution
  • 0.1 A / 0.1 V
  • Mounting Type
  • Bench-top
  • Capacity
  • Suitable for one Photo Cell
  • Machine Weight
  • Approx. 3 kg
  • Control Mode
  • Manual
  • User Manual
  • Detailed Operation and Experimentation Manual Included
  • Compliance
  • Meets Educational Experimentation Standards
  • Body Material
  • Powder Coated Metal Enclosure
  • Optical Arrangement
  • Movable Lamp for Distance Variation
  • Light Source
  • Tungsten Lamp with Intensity Control
  • Adjustment
  • Variable Voltage Control for Study
  • Included Meters
  • 0-50V Voltmeter, 0-200 A Microammeter
  • Connecting Accessories
  • Cables and Connecting Leads Provided
  • Safety
  • Fused and Earthed
 

PHOTO CELL CHARACTERISTICS APPARATUS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About PHOTO CELL CHARACTERISTICS APPARATUS

Photo Cell Characteristics Apparatus

InstrumentsComprises of DC supply 0-50 V DC Two round meters for voltage and currentmeasurement valve diagram is printed on front panel & light source withoutbulb.



Comprehensive Experimental Tool

This apparatus offers a complete solution for exploring photocell characteristics, supporting a wide current and voltage range with high measurement precision. The adjustable tungsten lamp and movable optical arrangement enable detailed investigation of light intensity and distance effects.


Robust Design and Safety

Built from powder-coated metal for enhanced durability, the equipment features fused and earthed safety measures, ensuring secure laboratory use. Its bench-top mounting design and compact size facilitate stable, convenient placement during experiments.


User-Friendly Operation

Supplied with all necessary cables and a well-illustrated user manual, the apparatus is designed for straightforward, manual control, allowing students and researchers to perform experiments with confidence and ease.

FAQ's of PHOTO CELL CHARACTERISTICS APPARATUS:


Q: How does the adjustable tungsten lamp enhance photocell experiments?

A: The tungsten lamp's adjustable intensity and movable positioning allow precise control over the light incident on the photocell. This enables users to study the effect of varying light intensity and distance on the voltage-current characteristics of the photocell, yielding comprehensive experimental data.

Q: What is the process for measuring voltage and current using this apparatus?

A: To measure voltage and current, connect the supplied leads to the provided analog voltmeter (0-50 V) and microammeter (0-200 A). Adjust the variable voltage control and light source as needed, then record the device readings to analyze the photocell's behavior under different conditions.

Q: When should this apparatus be used in an academic setting?

A: The Photo Cell Characteristics Apparatus is ideal for laboratory sessions in physics, electronics, or photonics curricula. It is particularly useful when teaching or investigating the photoelectric effect, allowing students to experimentally determine how photocells respond to various voltages and light intensities.

Q: Where is the apparatus typically installed and operated?

A: This equipment is designed for bench-top installation, making it suitable for use in academic laboratories, research facilities, and institutions requiring hands-on study of photocell behavior. Its compact form factor ensures it fits safely on standard laboratory benches.

Q: What applications benefit from the use of this apparatus?

A: This apparatus is valuable for academic demonstrations, research projects, and experimental investigations related to photocells. It assists users in understanding key scientific principles, supporting both classroom learning and advanced research without the need for automated controls.

Q: How does the safety feature protect users during experiments?

A: The apparatus incorporates fused and earthed circuits, which protect users from electrical hazards by minimizing the risk of circuit overloads and ensuring that any electrical faults are safely diverted away from the operator.

Q: What are the benefits of the included user manual?

A: The comprehensive manual guides users through the equipment setup, operational procedures, and sample experiments. This reduces setup errors, improves confidence, and enhances the learning outcomes for both instructors and students.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

H PLANE TEE

H PLANE TEE

Minimum Order Quantity : 1 Piece

Usage : RF and Microwave signal routing

Application : H PLANE TEE

Product Type : H PLANE TEE

DETERMINE YOUNGS MODULUSS, MODULUS OF RIGIDITY AND POISSONS RATIO OF THE MATERIAL OF A GIVEN WIRE BY SEARLES DYNAMICAL METHOD (COMPLETE SETUP)

DETERMINE YOUNGS MODULUSS, MODULUS OF RIGIDITY AND POISSONS RATIO OF THE MATERIAL OF A GIVEN WIRE BY SEARLES DYNAMICAL METHOD (COMPLETE SETUP)

Price 1400.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Application : DETERMINE YOUNGS MODULUSS, MODULUS OF RIGIDITY AND POISSONS RATIO OF THE MATERIAL OF A GIVEN WIRE BY SEARLES DYNAMICAL METHOD (COMPLETE SETUP)

Product Type : DETERMINE YOUNGS MODULUSS, MODULUS OF RIGIDITY AND POISSONS RATIO OF THE MATERIAL OF A GIVEN WIRE BY SEARLES DYNAMICAL METHOD (COMPLETE SETUP)

Power Supply : Manual

SINGLE PHASE HALF CONTROLLED DC DRIVE

SINGLE PHASE HALF CONTROLLED DC DRIVE

Minimum Order Quantity : 1 Piece

Usage : SINGLE PHASE HALF CONTROLLED DC DRIVE

Application : SINGLE PHASE HALF CONTROLLED DC DRIVE

Product Type : SINGLE PHASE HALF CONTROLLED DC DRIVE

RTL LOGIC GATES (5 IN 1)

RTL LOGIC GATES (5 IN 1)

Minimum Order Quantity : 1 Piece

Usage : RTL LOGIC GATES (5 IN 1)

Application : RTL LOGIC GATES (5 IN 1)

Product Type : RTL LOGIC GATES (5 IN 1)