trusted seller
Natural Draft Tray Dryer
Natural Draft Tray Dryer

Natural Draft Tray Dryer

MOQ : 1 Piece

Natural Draft Tray Dryer Specification

  • Accuracy
  • 1C
  • Power Source
  • Electric
  • Model No
  • NDTD-10
  • Core Components
  • Drying chamber, trays, heater (for temp. control), thermometer
  • Feature
  • Natural air draft, uniform heat distribution, double walled construction, insulated
  • Frequency
  • 50 Hz
  • Capacity
  • 10 Trays
  • Application
  • Mass Transfer Lab Equipments
  • Measurement Range
  • Ambient to 110C
  • Product Type
  • Natural Draft Tray Dryer
  • Automation Grade
  • Manual
  • Temperature Range
  • Ambient to 110C
  • Usage
  • Mass Transfer Lab Equipments
  • Voltage
  • 230 V AC
  • Equipment Materials
  • Mild Steel (MS) with powder coating
  • Type
  • Natural Draft Tray Dryer
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • 900 x 600 x 800 mm
  • Weight
  • Approx. 75 kg
  • Safety Features
  • Over-temperature protection
  • Tray Size
  • 300 x 200 mm each
  • Number of Trays
  • 10
  • Inner Chamber Material
  • Stainless Steel (SS-304)
  • Thermometer
  • Fitted for temperature monitoring
  • Drying Area
  • 0.6 m2
  • Heater Rating
  • 1 kW
  • Doors
  • Single door with locking arrangement
  • Insulation Material
  • Glass wool
  • Noise Level
  • Silent operation
  • Outer Finish
  • Powder coated MS
  • Air Circulation
  • Natural convection
  • Observation Window
  • Provided
 

Natural Draft Tray Dryer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Natural Draft Tray Dryer

Natural Draft Tray Dryer:

Owing to the vast experience and knowledge of this field, we have been able to offer premium quality Natural Draft Tray Dryer to prestigious customers. These dryers are commonly used for analyzing the moisture elimination by various condition of high temperature under natural draft action. This draft action is generated by the hot stream of air.

Specifications:

  • Electric supply Provide: 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater.
  • Material Saw dust @ 1Kg.
  • Support table Size: 500W x 500D x 750H in mm.



Robust Construction for Laboratory Use

The tray dryer boasts a double-walled body for enhanced insulation, protecting against heat loss and offering energy efficiency. Its stainless steel inner chamber allows for safe handling of chemical and biological samples, making it a reliable choice for frequent laboratory use. The powder coated exterior resists corrosion, and an observation window enables quick process checks without interrupting drying cycles.


Uniform Air Circulation and Accurate Temperature Control

Utilizing natural convection, the NDTD-10 ensures even heat distribution across all ten trays. The manual analog display and fitted thermometer allow precise monitoring and adjustment, maintaining temperatures within 1C accuracy. Over-temperature protection and insulated design guarantee safe and consistent operation for both teaching and research labs.

FAQs of Natural Draft Tray Dryer:


Q: How does the NDTD-10 Natural Draft Tray Dryer function in mass transfer laboratory settings?

A: The tray dryer utilizes natural air convection for uniform heat spread, allowing efficient drying of laboratory samples across ten trays, each sized at 300 x 200 mm. Its insulated chamber and fitted thermometer ensure accurate temperature regulation up to 110C, which is vital for mass transfer experiments.

Q: What safety features are integrated into this tray dryer during operation?

A: This model is equipped with over-temperature protection to prevent overheating, glass wool insulation for thermal safety, and a secure single door with locking arrangement. These features safeguard both the operator and the samples throughout the drying process.

Q: When should laboratories use the NDTD-10 Natural Draft Tray Dryer?

A: The tray dryer is suitable for mass transfer operations requiring controlled drying conditions. It can be employed for research, demonstrations, and experiment preparation involving chemical or biological samples needing gentle and uniform drying.

Q: Where can the NDTD-10 Tray Dryer be effectively installed?

A: It is ideally positioned in laboratory environments, especially those specializing in chemical engineering, biotechnology, or material science. Its compact dimensions (900 x 600 x 800 mm) make it suitable for benchtop or dedicated drying areas.

Q: What is the process for monitoring and adjusting drying parameters in this equipment?

A: Operators use the built-in analog thermometer to monitor temperature, adjusting settings via the manual controls. The observation window allows for visual checks of sample status during the drying process without disturbing chamber conditions.

Q: How does the natural air draft feature benefit laboratory drying applications?

A: Natural convection promotes energy efficiency by distributing heat uniformly without noisy fans. This results in silent operation, lower maintenance, and more consistent drying, which is beneficial for delicate samples or teaching environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Mass Transfer Lab Equipments Category

Vapour In Air Diffusion Apparatus

Vapour In Air Diffusion Apparatus

Minimum Order Quantity : 1 Piece

Type : Vapour In Air Diffusion Apparatus

Product Type : Vapour In Air Diffusion Apparatus

Application : Mass Transfer Lab Equipments

Display Type : Analog scale with graduated tube

Core Components : Diffusion Glass Tube, Liquid Reservoir, Mounted Base Plate, Graduated Scale

Coulometric Karl Fischer Titration System With Titration Controller and Titration Module

Coulometric Karl Fischer Titration System With Titration Controller and Titration Module

Minimum Order Quantity : 01 Piece

Type : Coulometric Karl Fischer Titrator

Product Type : Coulometric Karl Fischer Titration System With Titration Controller and Titration Module

Application : Mass Transfer Lab Equipments

Display Type : Digital LCD display

Core Components : Titration Controller, Titration Module, Electrode, Pump

Change of State of Gases

Change of State of Gases

Minimum Order Quantity : 1 , , Piece

Type : Change of State Experimental Unit

Product Type : Change of State of Gases

Application : Mass Transfer Lab Equipments

Display Type : Digital/Analog (as per model)

Core Components : Gas Cylinder, Heater, Thermocouples, Cooling Coil, Control Unit

Solids Handling Study Bench

Solids Handling Study Bench

Minimum Order Quantity : 1 , , Piece

Type : Solids Handling Study Bench

Product Type : Solids Handling Study Bench

Application : Mass Transfer Lab Equipments

Display Type : Analog scale

Core Components : Hoppers, Conveyor, Measuring Tray, Motor



Back to top