Natural Draft Tray Dryer Specification

  • Capacity
  • 10 Trays
  • Feature
  • Natural air draft, uniform heat distribution, double walled construction, insulated
  • Power Source
  • Electric
  • Core Components
  • Drying chamber, trays, heater (for temp. control), thermometer
  • Accuracy
  • ±1°C
  • Voltage
  • 230 V AC
  • Application
  • Mass Transfer Lab Equipments
  • Measurement Range
  • Ambient to 110°C
  • Model No
  • NDTD-10
  • Temperature Range
  • Ambient to 110°C
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Usage
  • Mass Transfer Lab Equipments
  • Product Type
  • Natural Draft Tray Dryer
  • Equipment Materials
  • Mild Steel (MS) with powder coating
  • Type
  • Natural Draft Tray Dryer
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • 900 x 600 x 800 mm
  • Weight
  • Approx. 75 kg
  • Noise Level
  • Silent operation
  • Number of Trays
  • 10
  • Thermometer
  • Fitted for temperature monitoring
  • Heater Rating
  • 1 kW
  • Tray Size
  • 300 x 200 mm each
  • Inner Chamber Material
  • Stainless Steel (SS-304)
  • Observation Window
  • Provided
  • Air Circulation
  • Natural convection
  • Safety Features
  • Over-temperature protection
  • Outer Finish
  • Powder coated MS
  • Insulation Material
  • Glass wool
  • Doors
  • Single door with locking arrangement
  • Drying Area
  • 0.6 m2
 

Natural Draft Tray Dryer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Natural Draft Tray Dryer

Natural Draft Tray Dryer:

Owing to the vast experience and knowledge of this field, we have been able to offer premium quality Natural Draft Tray Dryer to prestigious customers. These dryers are commonly used for analyzing the moisture elimination by various condition of high temperature under natural draft action. This draft action is generated by the hot stream of air.

Specifications:

  • Electric supply Provide: 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater.
  • Material Saw dust @ 1Kg.
  • Support table Size: 500W x 500D x 750H in mm.



Robust Construction for Laboratory Use

The tray dryer boasts a double-walled body for enhanced insulation, protecting against heat loss and offering energy efficiency. Its stainless steel inner chamber allows for safe handling of chemical and biological samples, making it a reliable choice for frequent laboratory use. The powder coated exterior resists corrosion, and an observation window enables quick process checks without interrupting drying cycles.


Uniform Air Circulation and Accurate Temperature Control

Utilizing natural convection, the NDTD-10 ensures even heat distribution across all ten trays. The manual analog display and fitted thermometer allow precise monitoring and adjustment, maintaining temperatures within 1C accuracy. Over-temperature protection and insulated design guarantee safe and consistent operation for both teaching and research labs.

FAQs of Natural Draft Tray Dryer:


Q: How does the NDTD-10 Natural Draft Tray Dryer function in mass transfer laboratory settings?

A: The tray dryer utilizes natural air convection for uniform heat spread, allowing efficient drying of laboratory samples across ten trays, each sized at 300 x 200 mm. Its insulated chamber and fitted thermometer ensure accurate temperature regulation up to 110C, which is vital for mass transfer experiments.

Q: What safety features are integrated into this tray dryer during operation?

A: This model is equipped with over-temperature protection to prevent overheating, glass wool insulation for thermal safety, and a secure single door with locking arrangement. These features safeguard both the operator and the samples throughout the drying process.

Q: When should laboratories use the NDTD-10 Natural Draft Tray Dryer?

A: The tray dryer is suitable for mass transfer operations requiring controlled drying conditions. It can be employed for research, demonstrations, and experiment preparation involving chemical or biological samples needing gentle and uniform drying.

Q: Where can the NDTD-10 Tray Dryer be effectively installed?

A: It is ideally positioned in laboratory environments, especially those specializing in chemical engineering, biotechnology, or material science. Its compact dimensions (900 x 600 x 800 mm) make it suitable for benchtop or dedicated drying areas.

Q: What is the process for monitoring and adjusting drying parameters in this equipment?

A: Operators use the built-in analog thermometer to monitor temperature, adjusting settings via the manual controls. The observation window allows for visual checks of sample status during the drying process without disturbing chamber conditions.

Q: How does the natural air draft feature benefit laboratory drying applications?

A: Natural convection promotes energy efficiency by distributing heat uniformly without noisy fans. This results in silent operation, lower maintenance, and more consistent drying, which is beneficial for delicate samples or teaching environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Mass Transfer Lab Equipments Category

Ph Control

Ph Control

Minimum Order Quantity : 1 Piece

Product Type : Ph Control

Type : Ph Control

Application : Mass Transfer Lab Equipments

Usage : Mass Transfer Lab Equipments

Frequency : 50 Hz

Absorption In Packed Bed

Absorption In Packed Bed

Minimum Order Quantity : 1 Piece

Product Type : Absorption In Packed Bed

Type : Mass Transfer Lab Equipment

Application : Mass Transfer Lab Equipments

Usage : Mass Transfer Lab Equipments

Frequency : 50 Hz

Sieve Plate Distillation Column

Sieve Plate Distillation Column

Minimum Order Quantity : 1 Piece

Usage : Education

Frequency : 50 Hertz (HZ)

LIQUID- LIQUID EXTRACTION IN A PACKED TOWER APPARATUS

LIQUID- LIQUID EXTRACTION IN A PACKED TOWER APPARATUS

Minimum Order Quantity : 1 Piece

Product Type : LIQUID LIQUID EXTRACTION IN A PACKED TOWER APPARATUS

Type : LIQUID LIQUID EXTRACTION IN A PACKED TOWER APPARATUS

Application : LIQUID LIQUID EXTRACTION IN A PACKED TOWER APPARATUS



Back to top