trusted seller
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .
Luminous Intensity .

Luminous Intensity .

Price 500.0 INR/ Piece

MOQ : 1 Piece

Luminous Intensity . Specification

  • Power Source
  • Electric
  • Product Type
  • Luminous Intensity
  • Temperature Range
  • Room Temperature Celsius (oC)
  • Application
  • General Lab Equipments
  • Accuracy
  • High C
  • Voltage
  • 220 V Volt (v)
  • Capacity
  • 6 Nos. Pcs/hr
  • Automation Grade
  • Manual
  • Measurement Range
  • 0-2000 Lux
  • Model No
  • Core Components
  • Sensor, Digital Display, Housing
  • Frequency
  • 50 Hz Hertz (HZ)
  • Feature
  • Accurate Measurement, Portable, Easy to Use
  • Usage
  • General Lab Equipments
  • Equipment Materials
  • Mild Steel
  • Type
  • Luminous Intensity
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 250 mm x 180 mm x 100 mm Millimeter (mm)
  • Weight
  • Specific details not available Grams (g)
  • Finish
  • Powder Coated
  • Resolution
  • 1 Lux
  • Operating Principle
  • Photometric Measurement
  • Protection Class
  • IP20
 

Luminous Intensity . Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Luminous Intensity .

Luminous Intensity
  • Range : 0 to 150 000 lux
  • Resolution : 27 lux

Luminous Intensity 

  • Range : 0 to 200 lux
  • Resolution : 0.05 lux
Luminous Power
  • Range : 0.1 to 10 W / m2
  • Resolution : 0.1 W / m2


Precise Photometric Measurement

Utilizing advanced sensor technology, It measures luminous intensity with high accuracy, ideal for laboratories needing consistent and repeatable results. Its digital display presents data with 1 Lux resolution, supporting critical experimental and equipment calibration tasks.


Built for Laboratory Use

The instrument is crafted from mild steel with a powder-coated finish, offering robust performance for everyday laboratory applications. Its IP20 protection class meets general lab safety requirements, and the compact size allows for easy placement and portability between workstations.


Effortless Operation and Portability

Designed for user-friendliness, Its features straightforward manual controls. With an automation grade of manual and an easy-to-read digital display, it facilitates quick measurements. Electric powered and suitable for room temperature operation, its readily deployable in a range of general lab settings.

FAQs of Luminous Intensity:


Q: How does the Luminous Intensity measure luminous intensity in laboratory environments?

A: The Luminous Intensity employs a precise photometric sensor to detect and quantify the intensity of visible light, displaying the measured value digitally. Its 1 Lux resolution ensures clear and accurate measurements, making it effective for standard laboratory tasks.

Q: What components are included in the Luminous Intensity Meter, model ?

A: This device features a durable mild steel housing with a powder-coated finish, a sensitive sensor, a digital display, and manual operation controls. These elements work together to provide reliable, user-friendly measurements in lab settings.

Q: When should I use the luminous intensity meter in my laboratory?

A: It is best suited for assessing light intensity as part of equipment calibration, photometric experiments, or validating illumination levels in general laboratory environments. Use it at room temperature within its specified range (02000 Lux) for optimal results.

Q: Where can the Luminous Intensity be positioned in the laboratory for correct operation?

A: Position the luminous intensity meter on a stable, flat surface, ideally close to the light source you intend to measure. Its compact design (250 mm x 180 mm x 100 mm) and portability let you move it easily within the lab as needed.

Q: What is the process of using the Luminous Intensity for measurements?

A: Place the device in the area where light intensity should be measured, power it via the electric supply (220 V), and use the manual operation interface to start readings. The digital display will show real-time lumen values with high accuracy.

Q: How does this luminance meter benefit laboratory users?

A: It provides accurate, fast, and repeatable measurements, helping users maintain consistent lighting standards in experiments and workspace calibration. Its easy-to-use design and durable construction enhance efficiency and reliability in laboratory routines.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in General Lab Equipments Category

Atomic Boxes

Atomic Boxes

Minimum Order Quantity : 1 Piece

Type : Atomic Boxes

Product Type : Atomic Boxes

Feature : Corrosion Resistant, Uniform Heating

Usage : General Lab Equipments

Amperemeter    .

Amperemeter .

Price 500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Type : Panel Mount Amperemeter

Product Type : Amperemeter

Feature : Easy to Read, Durable Construction, Shock Resistant

Usage : General Lab Equipments

Pivoting Hook Dynamometers Graduations

Pivoting Hook Dynamometers Graduations

Minimum Order Quantity : 10 Pieces

Type : Pivoting Hook Dynamometer

Product Type : Pivoting Hook Dynamometers Graduations

Feature : Pivot hook for easy attachment, Zero adjustment, Graduated for direct reading

Usage : General lab equipments

Filament Bulbs E10

Filament Bulbs E10

Minimum Order Quantity : 100 Pieces

Type : Filament Bulbs E10

Product Type : Filament Bulbs E10

Feature : Standard E10 base, Clear glass, Low wattage

Usage : General lab equipments



Back to top