trusted seller
Flow Rate Analyzer
Flow Rate Analyzer

Flow Rate Analyzer

MOQ : 1 Unit

Flow Rate Analyzer Specification

  • Interface Type
  • RS232 / USB
  • Operating Voltage
  • 230V
  • Frequency
  • 50Hz
  • Number of Specimens
  • Up to 3
  • Temperature
  • 10C - 50C
  • Automation Grade
  • Semi-automatic
  • Test Range
  • 0.1 - 10 l/min
  • Display Type
  • Digital LCD
  • Specimen Size
  • 40 x 50 mm
  • Port Size
  • 1/2 inch BSP
  • Product Type
  • Flow Measurement Apparatus
  • Application
  • Fluid Machines Equipments
  • Mounting Type
  • Bench-top
  • Gas Pressure
  • 0 - 6 bar
  • Measuring Range
  • 0.01 to 20 l/min
  • Max Height
  • 600 mm
  • Usage
  • Fluid Machines Equipments
  • Features
  • Auto-calibration, Data Logging, Overload Protection
  • Humidity
  • 0 - 95% RH
  • Accuracy
  • 0.5% F.S.
  • Resolution
  • 0.01 l/min
  • Response Time
  • <1 s
  • Hardness
  • Aluminum Body, Hard Anodized
  • Power Supply
  • 230V AC, 50Hz
  • Capacity
  • Max 5 Litres
  • Machine Weight
  • 18.8 kg
  • Test Speed
  • Variable (0.1 - 5 l/min)
  • Test Width
  • 50 mm
  • Test Stroke
  • 50 - 200 mm
  • Control Mode
  • Digital Automated
  • Protection Class
  • IP20
  • Data Storage Capacity
  • 1000 Test Reports
  • Ambient Operating Conditions
  • Indoor / Laboratory
  • Output
  • Analog & Digital
  • Alarm Type
  • High/Low Flow Visual & Audio
  • Calibration Standard
  • ISO / NIST Traceable
  • Flow Sensor Type
  • Turbine / Electromagnetic
  • Service Life
  • 10+ Years
  • Equipment Type
  • Flow Rate Analyzer
  • Material of Construction
  • High-strength Aluminum & SS
 

Flow Rate Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units, , Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Flow Rate Analyzer

Flow Measurement:



[1] different methods of flow rate measurement
[2] measuring instruments: orifice plate flow meter/measuring nozzle, Venturi nozzle and rotameter
[3] 6 tube manometers to determine the pressure distribution in Venturi nozzle, orifice plate flow meter and measuring nozzle
[4] measurement of the total pressure with Pilot tube
[5] flow rate determined by base module
[6] water supply  



Advanced Flow Measurement Technology

Utilizing turbine or electromagnetic sensors, the Flow Rate Analyzer guarantees high-precision readings with an accuracy of 0.5% F.S. The system operates within a measuring range of 0.01 to 20 l/min, making it suitable for a variety of laboratory and fluid machine applications. Its rapid response time and digital automation enhance efficiency during testing.


Reliable Construction & Durability

Manufactured with hard-anodized, high-strength aluminum and stainless steel components, the analyzer is built to withstand routine laboratory use. Its robust materials and IP20 protection ensure consistent operation in demanding ambient conditions, with a projected service life exceeding 10 years.


Comprehensive Data Management

Equipped with data logging and storage for up to 1,000 test reports, the device ensures all critical results are securely retained. RS232 and USB interfaces facilitate seamless data transfer, allowing integration with laboratory data systems and easy retrieval for analysis and reporting.

FAQs of Flow Rate Analyzer:


Q: How does the Flow Rate Analyzer ensure measurement accuracy?

A: The device incorporates high-precision turbine and electromagnetic flow sensors, compliant with ISO and NIST calibration standards, to deliver results with 0.5% full-scale accuracy. This guarantees reliable data for critical laboratory and equipment testing.

Q: What are the primary applications for this analyzer?

A: This analyzer is primarily used to measure liquid flow rates in fluid machines and related equipment, making it essential for laboratory testing, performance evaluation, and maintenance of pumps, meters, and similar devices.

Q: When should calibration be performed on the analyzer?

A: Calibration should be performed according to laboratory protocols and usage frequency. The analyzer supports auto-calibration, simplifying periodic maintenance and ensuring sustained measurement fidelity.

Q: Where is the Flow Rate Analyzer best installed?

A: Designed for bench-top mounting, the analyzer is intended for use in controlled indoor or laboratory settings, providing optimum performance under IP20-protected conditions.

Q: What is the process for conducting a flow test with this equipment?

A: Users position the specimen (measuring up to 40 x 50 mm) in the holder, configure the desired test parameters via the digital interface, and initiate the semi-automatic test sequence. The device logs and displays results in real-time, offering both visual and audio alarms if pre-set flow thresholds are exceeded.

Q: How does data logging benefit users of this analyzer?

A: Data logging allows users to store up to 1,000 test reports, facilitating traceability, compliance, and trend analysis. Reports can be exported through RS232 or USB interfaces for further review and documentation.

Q: What features contribute to the long service life and safety of the analyzer?

A: The analyzers high-strength, hard-anodized aluminum and stainless steel construction, overload protection, and built-in alarms all contribute to durability and user safety, ensuring the equipment can deliver reliable performance for over a decade.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Cavitation Demonstration Unit for Fluid Machines

Cavitation Demonstration Unit for Fluid Machines

Minimum Order Quantity : 1 Unit

Automation Grade : SemiAutomatic

Temperature : Ambient, 10C to 45C

Frequency : 50 Hz

Operating Voltage : 230V

Port Size : 25 mm

Series And Parallel Pump

Series And Parallel Pump

Minimum Order Quantity : 1 , , Unit

Automation Grade : SemiAutomatic

Temperature : 5C to 40C

Frequency : 50 Hz

Operating Voltage : 230V

Port Size : 1 inch

Impact Of Jet Apparatus

Impact Of Jet Apparatus

Minimum Order Quantity : 1 Unit

Automation Grade : Manual

Temperature : Operating Temperature: 5C to 40C

Frequency : 50 Hz

Operating Voltage : 230 V AC

Port Size : Inlet 1/2 BSP

Francis Turbine Apparatus

Francis Turbine Apparatus

Minimum Order Quantity : 1 , , Unit

Automation Grade : Manual / SemiAutomatic

Temperature : Room Temperature (10C to 40C)

Frequency : 50 Hz

Operating Voltage : 230 V

Port Size : Inlet: 25 mm, Outlet: 25 mm



Back to top