trusted seller
Filtration Unit
Filtration Unit

Filtration Unit

MOQ : 1 , , Piece

Filtration Unit Specification

  • Automation Grade
  • Manual & Semi-Automatic options available
  • Accuracy
  • High filtration efficiency (>99%)
  • Product Type
  • Filtration Assembly
  • Power Source
  • Electric (if supplied with vacuum pump)
  • Application
  • Pharmaceutical Lab Equipment
  • Measurement Range
  • Particle removal size down to 0.22m
  • Frequency
  • 50/60 Hz
  • Usage
  • Pharmaceutical Lab Equipment
  • Temperature Range
  • Up to 120C
  • Voltage
  • 230V AC
  • Feature
  • Easy to assemble/disassemble, Chemical-resistant, Leak-proof design
  • Model No
  • Provided on request or per order
  • Capacity
  • Varies by model (commonly from 5 to 100 liters)
  • Core Components
  • Filter Holder, Filter Paper/Membrane, Supporting Stand, Suction Flask
  • Equipment Materials
  • Stainless Steel 304/316, Borosilicate Glass, PTFE Seals
  • Type
  • Filtration Unit
  • Display Type
  • Analog/Mechanical Gauge
  • Dimension (L*W*H)
  • 500mm x 350mm x 900mm (varies by model)
  • Weight
  • 20-40 kg (approximate, depends on model)
  • Sample Compatibility
  • Aqueous & Organic solvents
  • Cleaning Method
  • Autoclavable/Steam Sterilizable
  • Connection Ports
  • Standard Hose Barb/BSP Threaded
  • Filtration Medium
  • Glass Microfiber, Cellulose Nitrate, or PTFE Membrane
  • Maximum Operating Pressure
  • 1.5 bar
  • Suction Type
  • Vacuum or Pressure Filtration
  • Operating Noise Level
  • < 65 dB (with vacuum pump)
  • Surface Finish
  • Polished Chrome or Satin Finish
  • Inlet/Outlet Size
  • 14 inch to 12 inch
  • Compliance
  • cGMP and ISO Standards
 

Filtration Unit Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • No
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Filtration Unit

Filtration Assembly:

  • Kit comprises of: All Glass Membrane Filter

  • Holder, Borosilicate Glass, 47mm, with Sintered

  • disc for membrane support and aluminum 'duck'

  • clamp. Vacuum Pump, Compact and efficient.

  • Silicon Rubber Tubing 6x9mm -1 mtr.

  • Pack of 100 Membranes, 47mm.




Versatile Filtration Capabilities

The filtration unit supports both vacuum and pressure-driven filtration, handling a wide spectrum of sample typesincluding aqueous and organic solvents. With a practical measurement range down to 0.22m, users can reliably separate fine particles, ensuring sample integrity in pharmaceutical processes. The units core components, such as filter holders and supporting stands, offer a stable and secure filtration setup every time.


Exceptional Compliance and Safety

Engineered for pharmaceutical lab environments, this unit adheres to stringent cGMP and ISO standards. Its chemical-resistant and leak-proof design, together with autoclavable components and an easy-to-clean polished or satin chrome finish, ensures maximum user safety and regulatory compliance.


Reliable Performance and Practical Design

Operating at noise levels under 65 dB when paired with a vacuum pump, this unit blends reliable performance with laboratory comfort. Its stainless steel and borosilicate glass construction, combined with PTFE seals, supports repeated use, long-term durability, and effective cleaningperfect for demanding, high-throughput laboratories.

FAQs of Filtration Unit:


Q: How does the filtration unit handle both aqueous and organic solvents?

A: The filtration unit is constructed from corrosion-resistant materials such as stainless steel 304/316, borosilicate glass, and PTFE seals. These ensure compatibility and durability when processing diverse samples, including both aqueous and organic solvents, making it suitable for a wide range of pharmaceutical applications.

Q: What cleaning and sterilization methods can be used with this filtration unit?

A: All wetted components of the unit are autoclavable and steam-sterilizable, allowing for effective cleaning and maintaining a contamination-free environment. The chemical-resistant materials enhance longevity even after repeated sterilization cycles.

Q: When should I use vacuum versus pressure filtration with this unit?

A: Choose vacuum filtration for rapid separation of particulates from liquid samples, such as clarifying or sterilizing solutions. Pressure filtration is preferred when working with viscous samples or when a faster flow rate through the filter is desired. The unit is engineered for safe use up to 1.5 bar pressure in both scenarios.

Q: Where can I install this filtration unit within my laboratory setup?

A: With compact dimensions and flexible inlet/outlet sizing ( inch to inch), the unit easily fits on typical laboratory benchtops or stands. Standard connection ports (hose barb or BSP threaded) simplify integration into existing lab infrastructure.

Q: What are the benefits of using glass microfiber, cellulose nitrate, or PTFE membrane as filter media?

A: Glass microfiber offers high particle retention and flow rates for general filtration. Cellulose nitrate is ideal for microbiological analysis due to low extractables, while PTFE membranes are chemically inert and suitable for aggressive solvents. This versatility allows you to select optimal media for differing applications.

Q: How does the filtration unit ensure operator safety and leak prevention?

A: The equipments leak-proof design, robust sealing with PTFE gaskets, and compliance with cGMP/ISO standards collectively ensure both operator safety and environmental protection against spills or exposure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Lab Equipment Category

Dissolution Rate Test Equipment

Dissolution Rate Test Equipment

Minimum Order Quantity : 1 Piece

Power Source : Electric

Usage : Pharmaceutical Lab Equipment

Capacity : 6 or 8 vessels as standard

Type : Dissolution Rate Test Equipment

Product Type : Dissolution Rate Test Equipment

Tablet Hardness Tester .

Tablet Hardness Tester .

Minimum Order Quantity : 1 Piece

Power Source : Manual

Usage : Tablet Hardness Tester

Capacity : Up to 20 Kg

Type : Tablet Hardness Tester

Product Type : Tablet Hardness Tester

Tablet Coating Pan

Tablet Coating Pan

Minimum Order Quantity : 1 , , Piece

Power Source : Electric

Usage : Tablet Coating Pan

Capacity : 15 Kg per batch

Type : Tablet Coating Pan

Product Type : Tablet Coating Pan

Membrane Filter Holder

Membrane Filter Holder

Minimum Order Quantity : 1 , , Piece

Power Source : Manual/Vacuum Driven

Usage : Pharmaceutical Lab Equipment

Capacity : Suitable for membrane diameter up to 47 mm

Type : Vacuum Type

Product Type : Membrane Filter Holder



Back to top