trusted seller
Energy Losses in Pipes Apparatus
Energy Losses in Pipes Apparatus

Energy Losses in Pipes Apparatus

MOQ : 1 , , Unit

Energy Losses in Pipes Apparatus Specification

  • Frequency
  • 50 Hz
  • Max Height
  • Approx. 900 mm
  • Product Type
  • Energy Losses in Pipes Apparatus
  • Test Range
  • 0 to 20 L/min (adjustable)
  • Power Supply
  • 230V AC, 50Hz, Single phase
  • Resolution
  • 1 mm (manometer reading)
  • Operating Voltage
  • 230V AC
  • Usage
  • Fluid Machines Equipments
  • Equipment Type
  • Energy Losses in Pipes Apparatus
  • Application
  • Fluid Machines Equipments
  • Measuring Range
  • 0-200 mm Water column differential (manometer)
  • Response Time
  • Instantaneous
  • Automation Grade
  • Manual
  • Mounting Type
  • Bench-top
  • Port Size
  • Inlet/outlet diameter - 15 mm or as required
  • Humidity
  • Up to 80% RH (Non-condensing)
  • Temperature
  • Ambient (10C to 40C)
  • Display Type
  • Analog scale (manometer)
  • Accuracy
  • 1% of full scale
  • Features
  • Modular setup with interchangeable pipes, visual demonstration, and transparent flow sections
  • Capacity
  • Water reservoir capacity approx. 25 litres
  • Machine Weight
  • Approx. 25 kg
  • Control Mode
  • Manual flow control valve
  • Pipe Material
  • Borosilicate glass / Stainless steel / PVC (as supplied)
  • Laboratory Requirement
  • Standard laboratory bench, drainage provision
  • Packing
  • Wooden box or export-safe packing
  • Demonstration Capability
  • Losses due to friction, bends, contraction, enlargement, single/double pipe set-up
  • Accessories Included
  • Set of pipes, connecting tubing, manometer liquid, measuring tank, instruction manual
  • Calibration
  • Factory calibrated and ready to use
  • Pressure Measurement
  • Three or more point manometric taps
  • Stand Material
  • Powder coated steel frame
  • Water Consumption
  • Recirculating system with minimum wastage
  • Pipe Types
  • Straight, Bend, Sudden Enlargement, Sudden Contraction
  • Flow Control
  • Needle valve or gate valve for fine adjustment
  • Pump Type
  • Centrifugal pump, 0.25 HP
  • Safety Features
  • Overload protection, anti-corrosion body
  • Flow Measurement
  • Pre-calibrated rotameter
  • Reservoir Type
  • Transparent water reservoir
 

Energy Losses in Pipes Apparatus Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Energy Losses in Pipes Apparatus

Energy Losses in Pipes Apparatus

Specification of Energy losses in pipe:

  • Investigation of pressure losses in piping elements and shut-off devices.
  • Different measuring objects for determining flow rate according to the differential pressure method.
  • Six pipe sections capable of being individually shutoff, with different piping elements: sudden contraction, sudden enlargement, Y-pieces, T-pieces, corners and bends.
  • One pipe section to hold interchangeable shutoff/measuring objects.
  • Measuring objects made of transparent material: Venturi nozzle, orifice plate flow meter and measuring nozzle.
  • Shut-off devices: angle seat valve, gate valve.
  • Annular chambers allow measurement of pressure without interaction.
  • 2 twin tube manometers for measuring the pressure difference.
  • Flow rate determined by base module.
  • Water supply using base module or via laboratory supply.


Modular and Visual Demonstration

The apparatus offers modularity with interchangeable pipes, allowing for experiments on various pipe materials and geometries. Transparent sections and a visual setup enable clear observation of water flow patterns and losses due to friction, bends, and cross-sectional changes, enhancing comprehension during practical demonstrations.


Precise Measurement and Control

Equipped with analog manometer readings and a pre-calibrated rotameter, the apparatus ensures accurate pressure and flow measurements. Needle or gate valve allows fine flow control, while factory calibration and immediate response times guarantee reliable data collection for laboratory experiments.


Efficient and Safe Operation

The system features recirculating water usage, overload protection and an anti-corrosion body for safe, durable operation. Easy to set up on a standard bench, all componentspipes, tubing, measuring tank, and manualare included, with a sturdy powder-coated steel frame and export-safe packaging for convenience and longevity.

FAQs of Energy Losses in Pipes Apparatus:


Q: How does the Energy Losses in Pipes Apparatus demonstrate fluid flow losses in different pipe configurations?

A: This apparatus allows users to install straight, bend, sudden enlargement, and contraction pipe types, each made from borosilicate glass, stainless steel, or PVC. Visual observation and multi-point manometric pressure taps reveal frictional and local losses during water flow under controlled conditions.

Q: What process should I follow to set up and operate this apparatus in my laboratory?

A: The apparatus is designed for bench-top use and requires a standard laboratory bench with drainage provisions. Installation involves connecting the set of supplied pipes, filling the transparent reservoir, adjusting the needle or gate valve for the desired flow rate, and using the manometer and rotameter to monitor measurements.

Q: When is calibration required for this apparatus?

A: No additional calibration is necessary upon delivery, as the system comes factory calibrated and ready to use. Regular checks and maintenance, as outlined in the instruction manual, help maintain measurement accuracy over time.

Q: Where can pressure and flow measurements be taken using this equipment?

A: The apparatus features three or more manometric taps placed at strategic pipe positions, enabling precise differential pressure measurements across various pipe sections. Flow can be measured using the pre-calibrated rotameter connected to the systems outlet.

Q: What are the safety features included, and how do they benefit users?

A: Safety is enhanced with overload protection for the centrifugal pump and an anti-corrosion body, ensuring reliable operation and reducing risk during extended laboratory use. The recirculating water system further avoids wastage and maintains efficiency.

Q: How is the apparatus beneficial for research and teaching applications?

A: With modular connectivity, interchangeable pipe materials, instant analog readings, and visual demonstration capabilities, the equipment supports detailed experiments and effective teaching for fluid mechanics topics, making it ideal for laboratories, technical institutes, and training centers.

Q: Can I adjust the flow and test range according to experimental requirements?

A: Yes, the apparatus offers manual flow control through a needle or gate valve. The test range is adjustable from 0 to 20 L/min, accommodating various experimental setups and study objectives with high measurement resolution and accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Machines Equipments Category

Cavitation Demonstration Unit for Fluid Machines

Cavitation Demonstration Unit for Fluid Machines

Minimum Order Quantity : 1 Unit

Measuring Range : 05 bar

Response Time : <1 s

Automation Grade : SemiAutomatic

Mounting Type : Benchtop

Temperature : Ambient, 10C to 45C

Pipe Surge and Water Hammer Apparatus

Pipe Surge and Water Hammer Apparatus

Minimum Order Quantity : 1 Unit

Measuring Range : 06 bar pressure gauge

Response Time : Instantaneous

Automation Grade : Manual/SemiAutomatic

Mounting Type : Table top

Temperature : Ambient, 5C to 40C

Bernoulli Apparatus

Bernoulli Apparatus

Minimum Order Quantity : 1 , , Unit

Measuring Range : 0 to 300 mm (water manometer)

Response Time : Immediate (analog reading)

Automation Grade : Manual

Mounting Type : Table top

Temperature : 5C to 40C

Computerized Venturi Meter

Computerized Venturi Meter

Minimum Order Quantity : 1 Piece

Measuring Range : 0.1 to 8 lps (liter per second)

Response Time : <2 seconds

Automation Grade : Automatic (computerized)

Mounting Type : Floor standing

Temperature : Operating range: 10C to 45C



Back to top