trusted seller
Distribution  Transformer Trainer
Distribution  Transformer Trainer

Distribution Transformer Trainer

MOQ : 1 Piece

Distribution Transformer Trainer Specification

  • Response Time
  • Instantaneous
  • Operating Voltage
  • 230V AC
  • Temperature
  • 0C to 50C
  • Power Supply
  • 230V AC, 50Hz
  • Measuring Range
  • 0-250V / 0-10A
  • Display Type
  • Digital Panel Meter
  • Max Height
  • 400 mm
  • Number of Specimens
  • Single Module
  • Port Size
  • Standard 4 mm safety sockets
  • Interface Type
  • Safety Terminals
  • Accuracy
  • 1%
  • Resolution
  • 1V / 0.1A
  • Mounting Type
  • Bench-top
  • Test Range
  • 0-250V AC for transformer input
  • Frequency
  • 50Hz
  • Features
  • Short-circuit protection, Load variation, Overload indication
  • Usage
  • Electrical Teaching Equipment
  • Humidity
  • Up to 85% RH
  • Automation Grade
  • Semi-Automatic
  • Application
  • Electrical Teaching Equipment
  • Specimen Size
  • Bench-mount module
  • Product Type
  • Distribution Transformer Trainer
  • Gas Pressure
  • N/A (Electrical Trainer)
  • Hardness
  • N/A (Not Applicable)
  • Capacity
  • Up to 1 kVA
  • Machine Weight
  • Approximately 30 kg
  • Test Speed
  • Manual and Automated options
  • Test Width
  • Standard trainer bench width
  • Test Stroke
  • Adjustable up to 100 mm
  • Control Mode
  • Digital and Switch-based
  • Learning Modules
  • Single-phase and Three-phase
  • Dimensions
  • 600 x 400 x 400 mm
  • Demonstrates
  • Voltage transformation, efficiency, short-circuit, open-circuit tests
  • Construction
  • Powder coated steel body
  • Transformer Winding
  • Primary and Secondary for Star and Delta
  • Instruction Manual
  • Included
  • Safety Features
  • Circuit breaker & fuse protection
  • Load Bank
  • Integrated resistive load
  • Connection Type
  • Banana plug cables included
  • Equipment Type
  • Distribution Transformer Trainer
  • Output Voltage
  • Variable-12V, 24V, 48V AC
  • Input Voltage
  • 230V AC
 

Distribution Transformer Trainer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Distribution Transformer Trainer

Distribution  Transformer Trainer  : MTS-855
Technical Specifications Distribution Transformer Trainer
OC SC TEST FOR THREE PHASE TRANSFORMER WITH PANNEL AND TRANSFORMER WITH DIGITAL PANEL METER DISPLAY.
The  Distribution Transformer Trainer, Model 885, is a portable, hands-on trainer designed to allow students to develop competence in completing single/three-phase transformer connections similar to those performed in the North American power distribution system.
The trainer contains two sets of three single-phase transformers to demonstrate three-phase banking configurations, such as wye-wye, delta-delta, closed delta-wye, closed wye-delta, open-wye, open-delta, and others. Each individual transformer winding is protected by a thermally-activated circuit breaker and designed to accept multiple faults.
The trainer is faul table in order to develop sound techniques for troubleshooting single-phase and three phase transformer banks. Eight (8) trainer faults are available.
The trainer is complete with a student laboratory manual written in a skill-building, performance-based format, allowing easy set-up of all laboratory exercises.

Features & Benefits :

The trainer allows students to perform the following tasks:
Identify different types of transformers.
Identify faulted transformers.
Test for proper no-load voltage.
Show how a three-phase transformer produces correct and incorrect motor rotation.
Show how the ratio of the transformer windings affects the secondary output voltage.
Show how to simulate parallel single-phase and three phase transformers.
Simulate a burned-out transformer in a three-phase bank, and how to connect the remaining transformers in open-wye and open-delta configurations to produce the correct voltage.
Topic Coverage.
Distribution Transformer Trainer.
Transformer Polarity and Terminal Markings.
Single-Phase Transformers Supplying Single-Phase Loads.
Single-Phase Paralleling.
Three-Phase Banking of Single-Phase Transformers.



Enhanced Learning with Practical Demonstrations

This transformer trainer bridges the gap between theory and application by enabling students to perform open-circuit, short-circuit, and efficiency experiments safely. The integrated resistive load bank and variable voltage output let users explore real-world electrical behaviors under different loading scenarios.


Safety and Durability Built In

Engineered with safety as a priority, the trainer incorporates circuit breaker and fuse protection, ensuring both users and equipment remain secure during operation. The steel body, robust design, and reliable safety terminals make it suitable for intensive lab use.


Versatile Module for Broad Curriculum Applications

Supporting both star and delta winding configurations across single and three-phase setups, this trainer is designed for diverse educational settings. With digital display meters, adjustable test parameters, and user-friendly bench mounting, it accommodates a wide range of instructional needs.

FAQs of Distribution Transformer Trainer:


Q: How can this trainer help students understand transformer operations?

A: The Distribution Transformer Trainer allows hands-on demonstrations of voltage transformation, efficiency evaluation, and various electrical tests like open-circuit and short-circuit. By simulating real-world conditions, students grasp fundamental transformer concepts more effectively.

Q: What safety features are included for user protection?

A: The trainer is equipped with circuit breaker and fuse protection as standard, along with overload indication and short-circuit protection. These features ensure safe operation during practical experiments, minimizing electrical risks.

Q: When is this equipment typically used in educational settings?

A: This trainer is commonly used during electrical engineering labs, practical workshops, and technical courses focusing on power systems, transformer principles, and electrical measurements. Its suitable for both classroom demonstrations and student-led experiments.

Q: Where can the transformer trainer be installed or used?

A: Designed as a bench-top module, the trainer can be installed on standard laboratory benches in classrooms, vocational training institutes, and technical colleges. Its compact dimensions and sturdy construction make it suitable for most educational environments.

Q: What is the process for conducting efficiency or voltage tests with this trainer?

A: Users connect the primary and secondary windings (star or delta configuration) using banana plug cables, apply input voltage, and adjust the load via the integrated bank. Digital meters display real-time voltage and current, enabling precise measurement during each test.

Q: How does the trainer accommodate varying educational needs and usage?

A: The trainer supports both manual and automated test options, variable output voltages, and different winding connections. Its modular design allows instructors and students to configure experiments based on curriculum requirements and learning objectives.

Q: What are the main benefits of using this distribution transformer trainer?

A: Key benefits include enhanced practical skills, a clear understanding of transformer performance, robust safety features, digital accuracy, and versatility in educational applications. It prepares students for real-world technical challenges in power distribution and electrical diagnostics.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

QAM MODULATION & DEMODULATION

QAM MODULATION & DEMODULATION

Minimum Order Quantity : 1 Piece

Usage : QAM MODULATION & DEMODULATION

Application : QAM MODULATION & DEMODULATION

Product Type : QAM MODULATION & DEMODULATION

Display Type : Analog and Panel meters

Accuracy : Analog Meter 2%

POLARITY  TEST OF POTENTIAL TRANSFORMER AND TERMINAL IDENTIFICATION

POLARITY TEST OF POTENTIAL TRANSFORMER AND TERMINAL IDENTIFICATION

Minimum Order Quantity : 1 Piece

Usage : POLARITY TEST OF POTENTIAL TRANSFORMER AND TERMINAL IDENTIFICATION

Application : POLARITY TEST OF POTENTIAL TRANSFORMER AND TERMINAL IDENTIFICATION

Product Type : POLARITY TEST OF POTENTIAL TRANSFORMER AND TERMINAL IDENTIFICATION

Display Type : DIGITAL

Accuracy : 99.9 %

SCR COMMUTATION TECHNIQUES

SCR COMMUTATION TECHNIQUES

Minimum Order Quantity : 1 Piece

Usage : SCR COMMUTATION TECHNIQUES

Application : SCR COMMUTATION TECHNIQUES

Product Type : SCR COMMUTATION TECHNIQUES

CURIE TEMPERATURE KIT

CURIE TEMPERATURE KIT

Minimum Order Quantity : 1 Piece

Usage : CURIE TEMPERATURE KIT

Application : CURIE TEMPERATURE KIT

Product Type : CURIE TEMPERATURE KIT



Back to top