trusted seller
Daniel Cell
Daniel Cell

Daniel Cell

MOQ : 1 Piece

Daniel Cell Specification

  • Voltage
  • Approx. 1.1 V (Open Circuit)
  • Product Type
  • Daniel Cell
  • Temperature Range
  • Room Temperature
  • Automation Grade
  • Manual
  • Usage
  • Engineering Electronic Instruments
  • Core Components
  • Porous Pot, Zinc Rod, Copper Plate
  • Power Source
  • Chemical Reaction
  • Application
  • Engineering Electronic Instruments
  • Capacity
  • 500 ml approx.
  • Model No
  • Standard Daniel Cell
  • Feature
  • Educational, Laboratory Use
  • Equipment Materials
  • Glass Vessel, Copper Plate, Porous Pot, Zinc Rod
  • Type
  • Electrochemical Cell
  • Dimension (L*W*H)
  • Vessel: 20 cm x 8 cm x 8 cm approx.
  • Weight
  • Approx. 800 gm
  • Portable
  • Yes
  • Assembly Required
  • No
  • Purpose
  • Demonstration of Electrochemical Principles
  • Finishing
  • Polished Glassware and Metal Components
 

Daniel Cell Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

Daniel Cell About



Ending Soon: Experience the Exclusive Daniel Cell, crafted with radiant polished glassware and virtuoso metal components. This immaculate electrochemical cell is portable and requires no assemblyjust grab it out of the box and get started. Designed specifically for demonstrating fundamental electrochemical principles, the standard Daniel Cell features a robust glass vessel, copper plate, zinc rod, and a porous pot. Its approximate 1.1 V output and 500 ml capacity make it perfect for laboratory and educational demonstrations. Secure your set todayyou wont want to miss out!

Demo-Ready for Educational Excellence

The Daniel Cell is engineered for educational institutions, laboratories, and engineering electronic instrument demonstrations. With its usage type focusing on academic and demonstration purposes, it stands out for its illuminating visual and hands-on learning value. Immaculate craftsmanship and effortless operation (no assembly required) make it a favored choice as a practical teaching aid in electrochemistry. Ideal for both students and educators, it provides clear insights into fundamental electrochemical processes.


Swift Dispatch and Hassle-Free Delivery

Stock Readyour Daniel Cell units are prepared for immediate dispatch from major Indian FOB ports. Goods transport is efficient; once your purchase order is confirmed, we ensure secure packing and swift delivery. Our sample policy accommodates your evaluation requirements, and the standard delivery timeline ranges from a few days to a week, depending on location. Choose us for reliable delivery and professional service for all your laboratory essentials.


FAQs of Daniel Cell:


Q: How does the Daniel Cell demonstrate electrochemical principles?

A: The Daniel Cell visually and practically demonstrates the transfer of electrons between zinc and copper via a chemical reaction, thereby generating a voltage and offering insights into electrochemical processes.

Q: What materials and components are included with the Daniel Cell?

A: Each unit includes a polished glass vessel, copper plate, porous pot, zinc rod, and all necessary components for immediate educational useno assembly is required.

Q: Where can the Daniel Cell be used most effectively?

A: It is most effective in educational laboratories, engineering classrooms, and electronic instrument demonstrations, serving as a valuable teaching tool in chemistry and physics curricula.

Q: When will my Daniel Cell order be delivered?

A: After submitting your purchase order, the Daniel Cell is dispatched from stock-ready inventory, with typical delivery times ranging from a few days to a week depending on your destination.

Q: What are the main benefits of using the Daniel Cell in an educational setting?

A: The Daniel Cell provides a clear, hands-on illustration of electrochemical concepts, enhancing comprehension and engagement for students while supporting teachers with reliable demonstration equipment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Engineering Electronic Instruments Category

Slip-ring 3 Induction Machines

Slip-ring 3 Induction Machines

Minimum Order Quantity : 1 , , Piece

Type : Slipring Induction Motor

Usage : Engineering Electronic Instruments

Product Type : Slipring 3 Induction Machines

Equipment Materials : Highgrade Steel & Copper

Application : Engineering Electronic Instruments

Power Supply Module

Power Supply Module

Minimum Order Quantity : 1 Piece

Type : Linear Power Supply Module

Usage : Engineering Electronic Instruments

Product Type : Power Supply Module

Equipment Materials : ABS Body with Metal Heat Sink

Application : Engineering Electronic Instruments

Digital Cum Linear Ic Tester

Digital Cum Linear Ic Tester

Minimum Order Quantity : 1 Piece

Type : IC Tester

Usage : Engineering Electronic Instruments

Product Type : Digital Cum Linear Ic Tester

Equipment Materials : Highimpact ABS Plastic body

Application : Engineering Electronic Instruments

PROGRAMMABLE POWER SUPPLY 0-30V/5A

PROGRAMMABLE POWER SUPPLY 0-30V/5A

Minimum Order Quantity : 1 Piece

Type : PROGRAMMABLE POWER SUPPLY 030V/5A

Usage : PROGRAMMABLE POWER SUPPLY 030V/5A

Product Type : PROGRAMMABLE POWER SUPPLY 030V/5A



Back to top