Cold Filter Plugging Point Apparatus Specification

  • Product Type
  • Cold Filter Plugging Point Apparatus
  • Power Supply
  • 230 V AC, 50 Hz
  • Interface Type
  • RS-232/USB
  • Mounting Type
  • Benchtop
  • Accuracy
  • 0.1C
  • Test Range
  • -60C to +51C
  • Features
  • Automatic timing, precise temperature control, over-temperature protection, robust construction
  • Measuring Range
  • -60C to +51C
  • Resolution
  • 0.1C
  • Hardness
  • Standard
  • Operating Voltage
  • 230 V AC
  • Humidity
  • Up to 85% RH, non-condensing
  • Application
  • Petroleum Testing Instruments
  • Automation Grade
  • Semi-Automatic
  • Response Time
  • < 6 seconds
  • Frequency
  • 50 Hz
  • Display Type
  • Digital LCD Display
  • Number of Specimens
  • Single or dual sample analysis
  • Gas Pressure
  • Max 5 bar (with integrated regulator)
  • Max Height
  • 480 mm
  • Port Size
  • Standard tubing (10 mm OD)
  • Temperature
  • Ambient 0C to +40C
  • Usage
  • Petroleum Testing Instruments
  • Specimen Size
  • 45 ml to 60 ml
  • Capacity
  • 2 samples (max)
  • Machine Weight
  • 18 kg
  • Test Speed
  • Standard automated cycle
  • Test Width
  • 30 mm filter assembly
  • Test Stroke
  • Configured per sample
  • Control Mode
  • Digital/Manual control
  • Cooling Medium
  • Environmentally friendly refrigerant
  • Filter Type
  • High precision glass fiber
  • Maintenance Mode
  • User-accessible routine maintenance menu
  • External Dimensions
  • 480 x 250 x 310 mm
  • Service Support
  • On-site and remote service available
  • Colour
  • Laboratory White & Blue
  • Filter Change Mechanism
  • Quick-release
  • Cooling System
  • Integrated advanced refrigeration unit
  • Included Accessories
  • Filter assemblies, sample containers, cleaning set
  • Data Output
  • Data export via USB/RS-232
  • Insulation
  • Double-wall thermal insulation
  • Drainage System
  • Integrated spill-resistant tray
  • Conformity
  • Complies with ASTM D6371
  • Sample Container Material
  • Borosilicate glass
  • Equipment Type
  • Cold Filter Plugging Point Apparatus
  • Safety
  • Overtemperature cut-off, overload protection
  • Calibration
  • Provided with calibration certificate
  • Ambient Temperature for Operation
  • +5C to +40C
 

Cold Filter Plugging Point Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Cold Filter Plugging Point Apparatus

Cold Filter Plugging Point Apparatus :

This apparatus is used for determination of cold filter plugging point  temperature of diesel and domestic fuels including those containing flow improving or other additives, intended for use in diesel engines and domestic heating installations. A specimen of the sample is cooled under specified conditions and, at intervals of 1OC, is drawn into a pipet under a controlled vacuum through a standardized wire mesh filter. The procedure is repeated until the amount of wax crystals that have separated out of solution is sufficient to stop or slow down the flow so that the time taken to fill the pipet exceeds 60 seconds or the fuel fails to return completely to the test jar before the fuel has cooled by a further 1OC.

Advanced Temperature Control & Precise Detection

Our CFPP apparatus is equipped with a high-precision refrigeration system and advanced temperature monitoring to deliver fast and reliable results. Achieve accuracy up to 0.1C, ideal for critical petroleum testing applications. Advanced safety features and robust construction ensure dependable, repeatable performance every time.


Safety, Compliance, and Ease of Use

Experience total confidence with built-in safety features including over-temperature protection and overload safeguards. The apparatus meets stringent ASTM D6371 standards, while intuitive digital/manual controls and user-accessible maintenance modes ensure smooth daily operation.


Efficient Data Management & Maintenance

Easily export test reports with USB/RS-232 data output. A dedicated maintenance menu facilitates routine checks, and the quick-release filter mechanism minimizes downtime between tests. The ergonomic spill-resistant drainage tray and comprehensive accessory set keep your laboratory workflow seamless.

FAQs of Cold Filter Plugging Point Apparatus:


Q: How does the advanced refrigeration unit benefit petroleum testing using this apparatus?

A: The integrated refrigeration unit ensures precise temperature control within -60C to +51C, offering fast and stable cooling for accurate assessment of cold filter plugging points in diesel and biodiesel fuels. This accuracy is crucial for determining fuel performance in low-temperature conditions.

Q: What safety features are included in the Cold Filter Plugging Point Apparatus?

A: Safety is prioritized with over-temperature cut-off, overload protection, and double-wall insulation. These features protect both the user and samples, providing secure operation even during intensive testing cycles.

Q: When should routine maintenance be performed on this apparatus?

A: Routine maintenance is recommended based on usage frequency and laboratory protocols. The built-in user-accessible maintenance menu guides users through routine service tasks, while on-site and remote support are available for technical assistance.

Q: Where can the CFPP apparatus be installed, and what are its space requirements?

A: The apparatus is designed for benchtop installation with external dimensions of 480 x 250 x 310 mm, making it suitable for most laboratory environments. Ensure operation within ambient temperatures of +5C to +40C and humidity up to 85% RH (non-condensing).

Q: What is the process for changing filters and draining residues after a test?

A: Filters can be changed quickly using the quick-release mechanism, minimizing handling time. The integrated spill-resistant drainage tray efficiently collects residues, simplifying cleaning and reducing contamination risks.

Q: How is test data managed and exported from the device?

A: Test data can be exported via USB or RS-232 interfaces, ensuring seamless digital records and easy integration with laboratory information management systems.

Q: What are the main benefits of using this CFPP apparatus in a petroleum laboratory?

A: Key benefits include highly accurate, automated sample testing, robust safety mechanisms, simple filter changes, digital connectivity for data export, and compliance with ASTM D6371. These features support reliable, efficient, and safe operations for petroleum laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Abels Flash Point

Abels Flash Point

Minimum Order Quantity : 1 Piece

Humidity : Ambient

Application : Petroleum Testing Instruments

Control Mode : Manual

Response Time : Immediate

Automation Grade : Manual

Oxidation Stability by Rotating Pressure Vessel Method

Oxidation Stability by Rotating Pressure Vessel Method

Minimum Order Quantity : 1 Piece

Humidity : Up to 95% RH

Application : Petroleum Testing Instruments

Control Mode : Automatic Digital Control

Response Time : <3 sec

Automation Grade : Automatic

Hydrocarbon Fractionation Unit

Hydrocarbon Fractionation Unit

Minimum Order Quantity : 1 Piece

Humidity : Ambient conditions

Application : Petroleum Testing Instruments

Control Mode : Automatic PLC based system

Response Time : <1 sec

Automation Grade : Automatic

Freezing Point Apparatus

Freezing Point Apparatus

Minimum Order Quantity : 1 Piece

Humidity : Ambient to Laboratory Controlled

Application : Petroleum Testing Instruments

Control Mode : Manual

Response Time : Less than 60 seconds

Automation Grade : Manual



Back to top