trusted seller
VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.

VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.

MOQ : 1 Piece

VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD. Specification

  • Humidity
  • Up to 85% RH (non-condensing)
  • Mounting Type
  • Bench-top unit
  • Number of Specimens
  • 1 alternator
  • Power Supply
  • 230 V 10%, 50 Hz, Single Phase AC
  • Accuracy
  • 1 % of reading
  • Features
  • Detachable load, protected wiring, instruction manual provided
  • Application
  • VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
  • Resolution
  • 0.01 A, 0.1 V
  • Test Range
  • 0 - 250 V (output voltage)
  • Operating Voltage
  • 230 V AC
  • Automation Grade
  • Manual
  • Display Type
  • Analog and Digital Meters
  • Response Time
  • Instantaneous (manual observation)
  • Interface Type
  • Panel mounted terminals and switches
  • Product Type
  • VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
  • Max Height
  • 50 cm
  • Equipment Type
  • VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.
  • Frequency
  • 50 Hz
  • Specimen Size
  • Standard laboratory alternator
  • Temperature
  • 10C to 50C (operating)
  • Measuring Range
  • 0 - 5 A (field/excitation current)
  • Usage
  • Educational Laboratory Experiment
  • Capacity
  • 1 kVA (typical alternator)
  • Machine Weight
  • Approx. 35 kg
  • Test Speed
  • 1500 rpm (synchronous speed)
  • Control Mode
  • Manual
  • Excitation System
  • DC shunt generator coupled
  • Instruction Manual
  • Comprehensive, experiment procedure included
  • Safety Protection
  • Fuses and MCB for overcurrent protection
  • Auxiliary Supply Voltage
  • Available (12 V DC for excitation)
  • Output Phase
  • Three-phase
  • Instrument Type
  • Voltmeters, Ammeters, Rheostats included
  • Enclosure
  • Powder coated metal body
  • Cabling
  • Shielded, color-coded
  • Loading
  • Lamp load bank (variable)
  • Rotor Type
  • Salient Pole
  • Alternator Rating
  • 1 kVA, 3-phase, 4-pole
  • Load Type
  • Zero Power Factor (lagging), resistive-inductive combination
  • Compliance
  • IS and IEC standards for lab equipment
 

VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD. Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.

Voltage Regulation of an Alternator by Zero Power Factor (Z.P.F.)method.

Suppliedwith DC Shunt Motor 2HP coupled with 3 Phase AC Alternator 1KVA fitted withProximity Sensor, Control Panel fitted with Necessary Meters, Variable VoltageThyristoried DC Drive ,DC Exitation Source & Digital RPM Meter

Accessoriesfor above

ResistiveLamp Load 1KW,3 Phase

InductiveLoad 10Amps, 3 Phase

DC Drive



Accurate Determination of Voltage Regulation

This apparatus employs the Z.P.F. method, simulating real-world lagging loads using a variable lamp load bank. With high-accuracy analog and digital meters, students and professionals can precisely calculate the alternator's voltage regulation and better understand alternator behavior under different loading.


Robust Safety and Compliance Features

The system safeguards both users and equipment with current-limiting fuses and MCBs, reinforced with a powder-coated metal enclosure and protected, color-coded wiring. This setup strictly adheres to IS and IEC standards, ensuring reliability in institutional and industrial labs.


Comprehensive Instructional Support

A detailed instruction manual is included, outlining experiment procedures, setup, and data acquisition. This fosters independent learning, making the equipment suitable for classroom demonstrations and self-guided practical sessions.

FAQ's of VOLTAGE REGULATION OF AN ALTERNATOR BY ZERO POWER FACTOR (Z.P.F.) METHOD.:


Q: How is the Zero Power Factor (Z.P.F.) method implemented in this alternator testing setup?

A: The Z.P.F. method is executed by coupling a DC shunt generator to the alternator for excitation and using a lamp load bank combined with inductance to create a zero power factor (lagging) condition. Precise measurements of terminal voltage and excitation current are made at different load levels using analog and digital meters.

Q: What safety measures are incorporated in this equipment?

A: To ensure operator and equipment safety, the system incorporates overcurrent protection through fuses and MCBs, a robust powder-coated metal body, and shielded, color-coded cabling for all connections.

Q: When should the Z.P.F. method be chosen over other voltage regulation methods?

A: The Z.P.F. method is preferred when accurate voltage regulation under heavy lagging power factor (such as industrial motor loads) is required, as it closely represents worst-case operating scenarios for alternators.

Q: Where can this equipment be most effectively used?

A: This setup is best suited for electrical engineering educational laboratories, research institutions, and vocational training centers seeking practical exposure to alternator performance and testing methods.

Q: What is the benefit of using panel-mounted analog and digital meters in this experiment?

A: Panel-mounted meters offer immediate, clear readings of voltage and current, aiding in manual data collection. The combination of analog and digital types enhances user familiarity with both measurement technologies.

Q: How does the instruction manual facilitate the learning process?

A: The comprehensive instruction manual details setup procedures, experiment steps, safety considerations, and measurement techniques, supporting students and instructors in conducting experiments confidently and effectively.

Q: What are the main usage scenarios for this alternator voltage regulation apparatus?

A: It is primarily employed for demonstrating and evaluating the voltage regulation characteristics of laboratory alternators under controlled, educational settings-particularly focusing on performance with zero power factor, lagging loads.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

MODULE FOR DOL STARTER CONTROL

MODULE FOR DOL STARTER CONTROL

Minimum Order Quantity : 1 Piece

Application : MODULE FOR DOL STARTER CONTROL

Usage : MODULE FOR DOL STARTER CONTROL

Product Type : MODULE FOR DOL STARTER CONTROL

Frequency : 50 Hz

Power Supply : 230V AC, 50 Hz

SYNCHRONOUS MOTOR 1 HP

SYNCHRONOUS MOTOR 1 HP

Minimum Order Quantity : 1 Piece

Application : SYNCHRONOUS MOTOR 1 HP

Usage : Continuous Duty Cycle

Product Type : SYNCHRONOUS MOTOR 1 HP

Frequency : 50 Hz

Power Supply : 415V, 3 Phase, 50 Hz AC

PARAMETER, EFFICIENCY AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC, SC & DIRECT LOADING TEST (ECONOMICAL MODEL)

PARAMETER, EFFICIENCY AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC, SC & DIRECT LOADING TEST (ECONOMICAL MODEL)

Minimum Order Quantity : 1 Piece

Application : PARAMETER, EFFICIENCY AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC, SC & DIRECT LOADING TEST (ECONOMICAL MODEL)

Usage : PARAMETER, EFFICIENCY AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC, SC & DIRECT LOADING TEST (ECONOMICAL MODEL)

Product Type : PARAMETER, EFFICIENCY AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC, SC & DIRECT LOADING TEST (ECONOMICAL MODEL)

Frequency : 50 Hertz (HZ)

Power Supply : ELECTRICAL

TRANSISTOR PUSH PULL AMPLIFIER

TRANSISTOR PUSH PULL AMPLIFIER

Minimum Order Quantity : 1 Piece

Frequency : 50 Hertz (HZ)

Power Supply : Electric



Back to top