trusted seller
TWO TANK INTERACTING SYSTEM APPARATUS
TWO TANK INTERACTING SYSTEM APPARATUS
TWO TANK INTERACTING SYSTEM APPARATUS
TWO TANK INTERACTING SYSTEM APPARATUS

TWO TANK INTERACTING SYSTEM APPARATUS

Price 100 INR/ Piece

MOQ : 1 Piece

TWO TANK INTERACTING SYSTEM APPARATUS Specification

  • Usage
  • TWO TANK INTERACTING SYSTEM APPARATUS
  • Power Supply
  • 230V AC, 50 Hz
  • Application
  • TWO TANK INTERACTING SYSTEM APPARATUS
  • Gas Pressure
  • Atmospheric
  • Equipment Type
  • Two Tank Interacting System Apparatus
  • Interface Type
  • Manual Valves
  • Test Range
  • 0-1000 ml (per tank)
  • Mounting Type
  • Tabletop
  • Port Size
  • 1/2 BSP
  • Max Height
  • 550 mm
  • Humidity
  • Up to 85% RH
  • Automation Grade
  • Semi-Automatic
  • Display Type
  • Acrylic graduated scale
  • Frequency
  • 50 Hz
  • Accuracy
  • 1 ml
  • Temperature
  • Ambient
  • Operating Voltage
  • 230V AC
  • Measuring Range
  • 0-1000 ml
  • Product Type
  • TWO TANK INTERACTING SYSTEM APPARATUS
  • Response Time
  • <2 seconds
  • Resolution
  • 1 ml
  • Features
  • Transparent tanks, Rigid construction, Corrosion resistant base
  • Capacity
  • 1 Litre (per tank)
  • Machine Weight
  • Approx. 18 kg
  • Control Mode
  • Manual/Automatic
 

TWO TANK INTERACTING SYSTEM APPARATUS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About TWO TANK INTERACTING SYSTEM APPARATUS

Description:

The setup studies behavior of multi capacity process whenconnected in non-interaction mode. It consists of supply tank, pump for watercirculation, Rotameter for flow measurement, two independent process tanks withscales connected in non-interacting mode. The components are assembled on frameto form tabletop set-up.

Experimentation:

To obtain experimentally the step response and to comparethe experimental and theoretical responses

Product Specifications

Usage: Laboratory

Material: Metal

Equipment Materials: PU

Type: Non-Interacting

Temperature Range: 35 Celsius (DEGREE C)



Transparent Design for Visual Learning

The clear acrylic tanks provide unobstructed visibility, allowing users to observe fluid movement and interactions in real time. This transparency is essential for educational demonstrations and data collection, enhancing understanding of system dynamics and response behaviors in laboratory studies.


Robust & Corrosion-Resistant Construction

Built with a powder-coated mild steel base and high-quality PVC connections, the apparatus resists corrosion and physical wear. Its rigid frame ensures stability during operation. The tabletop mounting provides easy integration into lab environments, making it suitable for repeated experimental use.


Precise Measurement & Fast Response

The system includes a graduated acrylic scale accurate to 1 ml and offers a rapid response time of less than 2 seconds. This enables reliable data acquisition in experiments, supported by flexible automation (manual or automatic) and easy flow control via panel valves.

FAQs of TWO TANK INTERACTING SYSTEM APPARATUS:


Q: How do I operate the Two Tank Interacting System Apparatus for experiments?

A: To operate, fill each clear acrylic tank with water up to the 1 litre capacity. Use the integrated flow control valves to adjust water flow manually or automatically. The centrifugal monoblock pump ensures steady circulation, and volume changes are measured using the graduated acrylic scale.

Q: What experiments can be conducted with this apparatus?

A: This system is ideal for studying interaction dynamics between two fluid tanks, calibration of fluid balance, and observing time-based system responses. It aids in practical demonstrations for process control and fluid measurement in academic or industrial labs.

Q: Where can this apparatus be installed and used?

A: The apparatus is designed for tabletop mounting, making it suitable for laboratory, research, and educational environments. Its compact size (650 mm x 300 mm x 550 mm) fits easily on benches or tables, allowing for convenient access and setup.

Q: What process is involved in draining the tanks after use?

A: Each tank is equipped with an individual drain valve. After experimentation, simply open the respective valve to empty the tank safely and efficiently, ensuring easy maintenance and cleaning.

Q: What are the benefits of having transparent acrylic tanks?

A: Transparent acrylic tanks allow users to visually monitor fluid levels, flow interactions, and system responses in real time. This enhances experimental accuracy and facilitates effective teaching demonstrations.

Q: When is automatic control recommended over manual operation?

A: Automatic control is recommended for repeatable processes that require precise and consistent flow adjustments. Manual operation is ideal for hands-on demonstrations, learning applications, or when user-defined interventions are needed during experiments.

Q: How accurate and responsive is the measuring system?

A: The acrylic graduated scale offers high measurement accuracy (1 ml), with a resolution of 1 ml and a system response time of less than 2 seconds, ensuring real-time and dependable data for experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Engineering Educational Equipment Category

Hall Effect Voltage Sensor

Hall Effect Voltage Sensor

Minimum Order Quantity : 1 Piece

Usage : Industrial

Temperature : 10+80 Celsius (oC)

Power Supply : Electric

Color : Blue

Humidity Sensor

Humidity Sensor

Minimum Order Quantity : 1 Piece

Usage : Industrial

Temperature : 0 to 50 Celsius (oC)

Power Supply : Electric

Color : Blue

Resistor, Vitreous Enamel

Resistor, Vitreous Enamel

Minimum Order Quantity : 10 Pieces

Usage : Industrial

Temperature : 55C to +225 Celsius (oC)

Power Supply : Electric

Color : Green

Hex Schmitt Trigger Inverter

Hex Schmitt Trigger Inverter

Minimum Order Quantity : 20 Pieces

Usage : Industrial

Temperature : 40 to +80 Celsius (oC)

Power Supply : Electric

Color : Black



Back to top