trusted seller
Two Shaft Gas Turbine Simulator
Two Shaft Gas Turbine Simulator

Two Shaft Gas Turbine Simulator

MOQ : 1 Piece

Two Shaft Gas Turbine Simulator Specification

  • Usage
  • Power Engines and Machines
  • Automation Grade
  • Semi-Automatic
  • Frequency
  • 50/60 Hz
  • Voltage
  • 230V AC
  • Accuracy
  • 0.5%
  • Feature
  • Real-Time Data Acquisition, Safety Interlocks, Modular Design
  • Core Components
  • Compressor, Combustion Chamber, Turbine, Control Panel
  • Temperature Range
  • 0C to 1000C
  • Model No
  • TSTS-01
  • Product Type
  • Two Shaft Gas Turbine Simulator
  • Application
  • Power Engines and Machines
  • Measurement Range
  • Speed: 060000 RPM, Pressure: 010 bar
  • Power Source
  • Electric
  • Capacity
  • 1 kW
  • Equipment Materials
  • Mild Steel and Stainless Steel
  • Type
  • Two Shaft Gas Turbine Simulator
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 1800 mm x 600 mm x 1500 mm
  • Weight
  • Approx. 50 kg
 

Two Shaft Gas Turbine Simulator Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Two Shaft Gas Turbine Simulator

Two Shaft Gas Turbine Simulator:

Micro Teknik is manufacture, exporters & suppliers

Technical Description Nine different process parameters can be set using potentiometers on the front panel of the benchtop unit. The software provides a wide range of diagrams and graphs. The simulator can model the theoretical system limits without hazard, limits at which real systems would be destroyed or seriously damaged. The unit comprises a control panel, data acquisition card and software..



Advanced Educational and Research Platform

This simulator bridges theoretical learning and practical application, making it invaluable for educational institutions and research facilities. Students and instructors benefit from real-time system adjustments, comprehensive data capture, and interactive touchscreen controls, fostering hands-on understanding of gas turbine dynamics in a controlled indoor environment.


Robust Engineering with Modern Safety

Constructed using mild and stainless steel, the simulator is engineered for durability and consistent performance. Advanced safety interlocks, overheat protection, and an emergency stop function prioritize user safety throughout operation, ensuring peace of mind during laboratory demonstrations and trials.


Flexible Data Management and Detail-Oriented Monitoring

With integrated USB and Ethernet connectivity, all test parameters, including pressure, temperature, and speed, are logged automatically. Digital sensors provide high-accuracy readings across broad operational ranges, enhancing data reliability for both demonstration and research applications.

FAQs of Two Shaft Gas Turbine Simulator:


Q: How does the Two Shaft Gas Turbine Simulator support educational demonstrations and research?

A: This simulator is designed specifically for hands-on training and experimental research. Its real-time data acquisition, touchscreen HMI, and accurate digital sensors give users an interactive experience, helping visualize turbine dynamics, fuel flow control, and safety features effectively during demonstrations and studies.

Q: What is the process for starting up and operating the gas turbine simulator?

A: Operation is simple: power on the simulator, select auto ignition via the HMI, and use the touchscreen to monitor parameters. The electronic regulator manages gas flow, and the system is ready for experimentation within five minutes. Safety interlocks and emergency stop features further simplify safe operation.

Q: When should data be logged and how is it accessed?

A: Data logging is continuous whenever the simulator is running. All measurement datapressure, temperature, speedare stored in real time and can be conveniently accessed or exported via USB or Ethernet connection, supporting post-experiment analysis and report generation.

Q: Where can this simulator be installed and used effectively?

A: This model is designed for indoor installation in laboratory settings such as academic institutions, technical training centers, or research labs. Its moderate size and robust build make it suitable for a wide range of indoor laboratory environments.

Q: What safety features are provided with the simulator?

A: The unit includes overheat protection, system emergency stop, and multiple safety interlocks. These features ensure safe shutdown during abnormal conditions and protect both users and equipment during demonstrations and experiments.

Q: How does using this simulator benefit turbine and engine training?

A: Users gain practical insights into turbine operation, control systems, and instrumentation. Its digital interface and comprehensive data logging help users understand system behaviors, diagnose faults, and optimize parameters, making training more informative and effective.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Power Engines and Machines Category

Single Stage Compressor Module

Single Stage Compressor Module

Minimum Order Quantity : 1 Piece

Voltage : 220V/380V AC

Accuracy : High Volumetric Efficiency

Usage : Power Engines and Machines

Automation Grade : SemiAutomatic

Frequency : 50/60 Hz

Two Stage Piston Compressor Unit

Two Stage Piston Compressor Unit

Minimum Order Quantity : 1 Piece

Voltage : 415 V

Accuracy : 2%

Usage : Power Engines and Machines

Automation Grade : Semi Automatic

Frequency : 50 Hz

Jet Turbine Module

Jet Turbine Module

Minimum Order Quantity : 1 Piece

Voltage : 230 V AC

Accuracy : 1%

Usage : Power Engines and Machines

Automation Grade : SemiAutomatic

Frequency : 50/60 Hz

Air Compressor Test Unit

Air Compressor Test Unit

Minimum Order Quantity : 1 Piece

Voltage : 230V AC

Accuracy : 1.5%

Usage : Power Engines and Machines

Automation Grade : SemiAutomatic

Frequency : 50 Hz



Back to top