MOQ : 1 Piece

SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR Specification

  • Display Type
  • Digital LED/LCD meters
  • Number of Specimens
  • 1 Alternator (expandable)
  • Response Time
  • <1 second
  • Automation Grade
  • Semi-automatic with manual controls
  • Equipment Type
  • SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR
  • Accuracy
  • 1% of full scale
  • Humidity
  • Up to 85% RH (non-condensing)
  • Resolution
  • 1 V / 0.01 A
  • Max Height
  • 45 cm
  • Product Type
  • SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR
  • Features
  • Over/under voltage, phase sequence indicators, frequency counters, lamp-synchroscope test
  • Frequency
  • 50 Hz
  • Mounting Type
  • Table-top
  • Measuring Range
  • 0-500 V, 0-5 A (metered output)
  • Power Supply
  • 230V AC, 50 Hz
  • Interface Type
  • 4 mm safety terminals, optional PC interface
  • Temperature
  • 0C to 50C
  • Application
  • SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR
  • Operating Voltage
  • 230V AC
  • Specimen Size
  • Up to 2 kVA alternator
  • Test Range
  • Synchronization across full generator output
  • Usage
  • Educational, laboratory experiments
  • Capacity
  • Up to 2 kVA (Single Alternator)
  • Machine Weight
  • Approx. 30 kg
  • Control Mode
  • Manual and Automatic Synchronization
  • Wiring Method
  • Patch cord-based, flexible
  • Included Accessories
  • Connection leads, alternator, bus bar unit, instruction manual
  • Compliance
  • IEC standard components
  • Indicating Lamps
  • Large front panel lamps for visual indication
  • Panel Construction
  • Powder coated metal
  • Circuit Protection
  • MCB and safety fuses included
  • Bus Bar Simulation
  • Infinity bus via solid-state electronics
  • Synchronization Modes
  • Lamp-dark, lamp-bright, and synchroscope method support
  • Dimensions
  • 600 mm x 400 mm x 300 mm
  • Alternator Type
  • Synchronous, 3-phase
  • Noise Level
  • <60 dB
 

SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR About

Synchronization of Alternator with Infinity Bus Bar.

Suppliedwith DC Shunt Motor 2HP coupled with 3 phase AC Alternator 1KVA & ControlPanel fitted with Necessary Meters, Variable Voltage Thyristoried DC Drive,Synchronoscope, Frequency Meter & DC Exitation Source.

Accessoriesfor above

ResistiveLamp Load 1KW, 3 Phase

ABS Testing Setup



Versatile Synchronization Methods

This equipment supports multiple synchronization techniques, including lamp-dark, lamp-bright, and synchroscope, allowing users to explore and master different practical approaches. The inclusion of large front panel lamps and digital displays makes monitoring synchronization effortless and precise, catering to both manual and automatic scenarios.


Safe and Reliable Operation

Safety is integral, featuring MCBs, fuses, and IEC-standard components. The system limits noise to below 60 dB and operates reliably from 0C to 50C with up to 85% non-condensing humidity, making it suitable for laboratory and educational settings. Table-top construction and robust metal housing ensure ease of use and durability.


Comprehensive Accessories and Expansion

The package includes all necessary leads, a single alternator (expandable up to 2 kVA), a bus bar unit, and a detailed instruction manual, offering a complete toolkit for students and professionals. The flexible patch cord wiring simplifies connections for repeated experiments and rapid configuration changes.

FAQ's of SYNCHRONIZATION OF ALTERNATOR WITH INFINITY BUS BAR:


Q: How does the synchronization process work with this alternator and infinity bus bar setup?

A: Synchronization involves matching the alternator's voltage, frequency, and phase sequence to those of the simulated infinity bus using lamp-dark, lamp-bright, or a synchroscope method. Visual indicators and digital meters guide users to achieve precise alignment before connecting the alternator to the bus bar safely.

Q: What protection features are included to ensure safety during operation?

A: The panel features circuit protection through miniature circuit breakers (MCBs) and safety fuses. All components conform to IEC standards, ensuring reliable and safe usage during synchronization experiments and demonstrations.

Q: When would you use the manual versus automatic synchronization controls?

A: Manual synchronization is ideal for learning and demonstration purposes, offering hands-on experience with real-time visual feedback via lamps and meters. Automatic mode streamlines the process, useful during repetitive training or high-precision applications where efficiency is required.

Q: Where can this equipment be used, and what is its primary application?

A: Designed for educational laboratories, universities, and technical institutes across India and beyond, the equipment is used to teach and demonstrate the principles and practicalities of synchronizing an alternator with a bus bar in power systems.

Q: What are the main benefits of using a patch cord-based wiring method?

A: Patch cord wiring offers flexibility and ease of reconfiguration, allowing rapid and safe connection changes without tools. This design supports multiple experiment setups and reduces wear on the apparatus, which is especially beneficial in busy laboratory environments.

Q: How is the alternator's output monitored during synchronization tests?

A: Output voltage and current are measured using digital LED/LCD meters, with a measuring range of 0-500 V and 0-5 A, featuring a high accuracy of 1% and fast response time (<1 second). This ensures accurate monitoring throughout the synchronization process.

Q: What are the advantages of the included indicating lamps during the synchronization process?

A: The large front panel lamps provide clear, immediate visual cues for phase alignment and synchronization status, helping users swiftly identify when parameters are matched and it is safe to close the breaker between the alternator and bus bar.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

WORK BENCH FOR AC SQUIRREL CAGE INDUCTION MOTOR 3 PHASE

WORK BENCH FOR AC SQUIRREL CAGE INDUCTION MOTOR 3 PHASE

Minimum Order Quantity : 1 Piece

Product Type : WORK BENCH FOR AC SQUIRREL CAGE INDUCTION MOTOR 3 PHASE

Usage : Motor testing, academic experiments, vocational training

Application : WORK BENCH FOR AC SQUIRREL CAGE INDUCTION MOTOR 3 PHASE

Accuracy : 1%

Equipment Type : WORK BENCH FOR AC SQUIRREL CAGE INDUCTION MOTOR 3 PHASE

VARIAC 4 AMPS SINGLE PHASE

VARIAC 4 AMPS SINGLE PHASE

Minimum Order Quantity : 1 Piece

Product Type : VARIAC 4 AMPS SINGLE PHASE

Usage : Laboratory, Educational, Industrial Use

Application : VARIAC 4 AMPS SINGLE PHASE

Accuracy : b1 1% (Voltage Output)

Equipment Type : VARIAC 4 AMPS SINGLE PHASE

Arduino Nano

Arduino Nano

Minimum Order Quantity : 1 Unit

Product Type : Arduino Nano

Usage : electrical teaching

Application : electrical teaching

Accuracy : 99.9 %

DC SHUNT GENERATOR 0.5 KW

DC SHUNT GENERATOR 0.5 KW

Minimum Order Quantity : 1 Piece

Product Type : DC SHUNT GENERATOR 0.5 KW

Usage : DC SHUNT GENERATOR 0.5 KW

Application : DC SHUNT GENERATOR 0.5 KW

Equipment Type : DC SHUNT GENERATOR 0.5 KW



Back to top