trusted seller
SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD

SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD

MOQ : 1 Piece

SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD Specification

  • Measuring Range
  • Voltage: 0-500V, Current: 0-10A (as per panel meters)
  • Mounting Type
  • Table-top
  • Automation Grade
  • Manual
  • Temperature
  • Operating 0C to 50C
  • Humidity
  • Up to 80% RH non-condensing
  • Operating Voltage
  • 415V AC
  • Number of Specimens
  • 2 alternators
  • Max Height
  • 700 mm
  • Specimen Size
  • Standard laboratory size alternators
  • Display Type
  • Analog panel meters
  • Product Type
  • SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
  • Equipment Type
  • SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
  • Interface Type
  • Manual via lamp method, connection terminals provided
  • Application
  • SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD
  • Test Range
  • 0-415V, 0-5A (with meters provided)
  • Frequency
  • 50Hz
  • Resolution
  • 1V/0.1A (depending on panel meter)
  • Power Supply
  • 3 Phase, 415V AC, 50Hz
  • Features
  • Two bright & one dark lamp synchronization method, rugged construction, safety interlocks, easy connections
  • Accuracy
  • Class 1.5 panel meters
  • Response Time
  • Instantaneous (depends on manual observation)
  • Usage
  • Educational/Research laboratory
  • Capacity
  • Typically up to 1 kVA per alternator
  • Machine Weight
  • Approx. 30 kg
  • Test Speed
  • Synchronous speed, typically 1500 RPM (for 4 pole, 50Hz alternators)
  • Test Width
  • 600 mm
  • Control Mode
  • Manual synchronization by lamp method
  • Wiring
  • Supplied with color-coded leads
  • Prime Mover
  • Coupled DC shunt motor or induction motor (supplied as per configuration)
  • Synchronoscope
  • Optional, for advanced experiments
  • Dimensions
  • Approx. 700 x 600 x 500 mm
  • Safety Features
  • Terminal shrouds, earth leakage protection
  • Build Material
  • Powder coated MS enclosure
  • Protection
  • MCB for short circuit and overload
  • Training Manual
  • Comprehensive user and experiment manual included
  • Alternators Type
  • Squirrel cage type, 3 phase
  • Lamp Rating
  • 230V, 40W (typically used for lamp method)
 

SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD

Synchronization and parallel operation of Two 3 Phase Alternators by twobright & one dark lamp method.

Suppliedwith 2 Set of DC Shunt Motor 2HP coupled with 3 phase AC Alternator 1KVA &Control Panel fitted with Necessary Meters, Variable Voltage Thyristoried DCDrives , Synchro no scope, Frequency Meter , Under/Over Voltage

Relay &DC Exitation Source

Accessoriesfor above

ResistiveLamp Load 1KW, 3 Phase

ResistiveLamp Load 1KW, 3 Phase



Hands-On Synchronization Demonstration

This equipment provides a practical learning platform for understanding the synchronization of two three-phase alternators using the two bright and one dark lamp method. It is particularly suitable for electrical engineering laboratories and research settings, offering tangible experience with standard industry techniques.


Robust and Safe Construction

Engineered with a powder-coated MS enclosure and comprehensive safety features, the equipment emphasizes user protection. Terminal shrouds, MCBs, and earth leakage safeguards are implemented, while color-coded wiring ensures safe and clear connections during experiments.


Comprehensive Training and Support

A detailed training and experiment manual accompanies each unit, guiding users through the setup, experiment procedures, and theoretical concepts. Support for advanced experiments is available with an optional synchronoscope, further enhancing the learning experience.

FAQ's of SYNCHRONIZATION AND PARALLEL OPERATION OF TWO 3 PHASE ALTERNATORS BY TWO BRIGHT & ONE DARK LAMP METHOD:


Q: How do you synchronize two three-phase alternators using the two bright and one dark lamp method?

A: The process involves connecting three lamps between corresponding phases of the alternators. As the incoming alternator approaches synchronism with the running one, two lamps glow brightly and one appears dark, indicating the correct moment for closing the breaker and synchronizing both machines.

Q: What is the primary use of this synchronization equipment?

A: This equipment is primarily used for educational and research purposes in laboratories to demonstrate the manual synchronization and parallel operation of two three-phase alternators using the lamp method.

Q: When should the circuit breaker be closed during synchronization using the lamp method?

A: The breaker should be closed at the exact instant when two lamps are bright and one is dark, signaling that the incoming alternator's phase sequence, voltage, and frequency are matched with the running alternator.

Q: Where can this equipment be installed and operated?

A: It is designed for table-top use in controlled environments such as educational and research laboratories, where practical demonstrations of alternator synchronization are needed.

Q: What safety features are included in this equipment?

A: The setup includes a molded case circuit breaker (MCB) for short circuit and overload protection, terminal shrouds, and earth leakage protection, ensuring user safety during laboratory experiments.

Q: How does using this equipment benefit students and researchers?

A: It provides a hands-on method for understanding alternator synchronization and parallel operation, reinforcing theoretical concepts and developing practical skills essential for the electrical engineering field.

Q: What type of prime mover is used with the alternators in this setup?

A: The alternators in this kit can be coupled with a DC shunt motor or an induction motor, supplied according to the experimental configuration required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

OC & SC TEST OF 3 PHASE SYNCHRONOUS MACHINE

OC & SC TEST OF 3 PHASE SYNCHRONOUS MACHINE

Minimum Order Quantity : 1 Piece

Product Type : OC & SC TEST OF 3 PHASE SYNCHRONOUS MACHINE

Application : OC & SC TEST OF 3 PHASE SYNCHRONOUS MACHINE

Usage : Electrical Laboratory, Engineering Colleges

Temperature : 0C to 50C

Control Mode : Manual / Automatic

LIQUID DIELECTRIC CELL

LIQUID DIELECTRIC CELL

Minimum Order Quantity : 1 Piece

Product Type : LIQUID DIELECTRIC CELL

Application : LIQUID DIELECTRIC CELL

Usage : LIQUID DIELECTRIC CELL

Temperature : Ambient room temperature

Control Mode : Manual

INDUCTION MOTOR 1 PHASE 1 HP CAPACITOR TYPE

INDUCTION MOTOR 1 PHASE 1 HP CAPACITOR TYPE

Minimum Order Quantity : 1 Piece

Product Type : INDUCTION MOTOR 1 PHASE 1 HP CAPACITOR TYPE

Application : INDUCTION MOTOR 1 PHASE 1 HP CAPACITOR TYPE

Usage : Industrial, Household, Commercial

Temperature : 15C to +40C (Operating)

Control Mode : Manual

Arduino Nano

Arduino Nano

Minimum Order Quantity : 1 Unit

Product Type : Arduino Nano

Application : electrical teaching

Usage : electrical teaching

Temperature : 20 to 70 Celsius (oC)



Back to top