SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER
SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER
SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER
SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER

MOQ : 1 Piece

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER Specification

  • Accuracy
  • 0.5%
  • Temperature
  • 5C to 50C operating
  • Response Time
  • Instantaneous
  • Specimen Size
  • Standard Single Phase Transformer (as per rating)
  • Features
  • Back to back testing, protection features, digital metering
  • Product Type
  • SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER
  • Measuring Range
  • 0 to 250 V AC, 0 to 5/10/20 A AC
  • Application
  • Performance evaluation of single phase transformers
  • Resolution
  • 0.01 V / 0.01 A
  • Test Range
  • Suitable for 1 kVA to 3 kVA Transformers
  • Equipment Type
  • SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER
  • Mounting Type
  • Table Top
  • Operating Voltage
  • 230 V AC
  • Power Supply
  • 230 V AC, 50 Hz, Single Phase
  • Frequency
  • 50 Hz
  • Max Height
  • Standard Laboratory Setup
  • Interface Type
  • Analog/Digital
  • Humidity
  • Up to 85% RH non-condensing
  • Display Type
  • Digital meters
  • Automation Grade
  • Semi-Automatic / Manual
  • Number of Specimens
  • 2 Transformers (identical rating)
  • Usage
  • Educational, Laboratory, Research
  • Capacity
  • 1 kVA to 3 kVA
  • Machine Weight
  • Approx. 65 kg
  • Test Speed
  • Manual / As per Test Procedure
  • Control Mode
  • Manual / Automatic (Optional)
  • Compliant Standards
  • IS 1180, IS 2026 (as applicable)
  • Instrument Protection
  • MCB/Overload Relays
  • Insulation Class
  • Class B
  • Cooling Type
  • Air-cooled
  • Safety Features
  • Emergency Stop Switch, Earth Leakage Relay
  • Included Accessories
  • Connection leads, Manual, Safety fuses
  • Connection Type
  • 4-wire system
  • Enclosure Material
  • Powder Coated Steel
  • Included Meters
  • Voltmeters, Ammeters, Wattmeters (Digital)
  • Test Method
  • Sumpner's (Back-to-Back) Test
  • Transformer Type
  • Single Phase, identical rating
 

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER About

Sumpner's (Back to Back) Test on Single Phase Transformer

ControlPanel fitted with Necessary Meters, Supplied with 2 Nos of 1 Phase Transformers1KVA & Thermometer 100C

Accessoriesfor above

Variac 10Amps Single Phase



Comprehensive Performance Testing

This system enables reliable back-to-back (Sumpner's) testing on two single-phase transformers of identical rating. It is specifically designed to evaluate transformer losses under full-load conditions, offering precise readings with high accuracy (0.5%) and a resolution of 0.01 V/A via digital meters. The procedure can be executed either semi-automatically or manually to fit various laboratory and research requirements.


Advanced Safety and Protection

Equipped with earth leakage relay, safety fuses, MCB/overload relays, and an emergency stop switch, this testing equipment prioritizes user and instrument protection. These safety features ensure that testing is conducted in compliance with IS 1180 and IS 2026 standards, reducing operational hazards and providing peace of mind during intensive transformer evaluations.


User-Friendly Interface and Accessories

With a broad measuring range and instant digital display, technicians benefit from rapid data feedback. Included accessories-such as connection leads, manuals, and safety fuses-streamline the testing process. The table-top, powder-coated steel design ensures durability and adaptability in various environments, supporting educational, laboratory, and research applications across India.

FAQ's of SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER:


Q: How does the Sumpners (Back-to-Back) Test evaluate transformer performance?

A: Sumpners Test, also known as the back-to-back test, evaluates the full-load losses and temperature rise of two identical single-phase transformers by connecting them in parallel. This method simulates real operational conditions without the need for a full-load external source.

Q: What safety features are included in this testing equipment?

A: The system integrates multiple protection components such as MCB/overload relays, earth leakage relay, safety fuses, and an emergency stop switch, offering layered defense against electrical faults and ensuring safe operation during testing.

Q: When and where is this test method typically used?

A: This test is commonly employed in electrical laboratories, research institutions, and educational settings for performance evaluation of transformers. It is suitable whenever accurate analysis of full-load characteristics is required, especially during routine quality checks or research studies.

Q: What process should be followed for conducting the Sumpners test using this system?

A: Begin by connecting two identical single-phase transformers as per the provided manual and ensure all safety accessories are in place. During testing, use the digital meters to monitor voltage, current, and power readings. Follow the test procedure manually or use the optional semi-automatic controls.

Q: Which transformer ratings can be tested with this equipment?

A: The system supports testing of single-phase transformers ranging from 1 kVA to 3 kVA, provided the two specimens are of identical ratings as per standard size requirements.

Q: How does the inclusion of digital metering and instant response benefit the user?

A: Digital voltmeters, ammeters, and wattmeters deliver precise real-time readings with 0.5% accuracy, helping users monitor transformer behavior effectively and make data-driven decisions during performance evaluation.

Q: What are the environmental and power requirements for operation?

A: The equipment operates at 230 V AC, 50 Hz single-phase power and is suitable for environments with up to 85% relative humidity (non-condensing) and temperatures between 5C to 50C, making it ideal for standard laboratory conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

UNIVERSAL B.H CURVE APPARATUS

UNIVERSAL B.H CURVE APPARATUS

Minimum Order Quantity : 1 Piece

Usage : UNIVERSAL B.H CURVE APPARATUS

Product Type : UNIVERSAL B.H CURVE APPARATUS

Application : UNIVERSAL B.H CURVE APPARATUS

SINGLE PHASE TRANSFORMER 2KVA/230VAC WITH TAPPINGS AT 50% & 86.6% AIR COOLED

SINGLE PHASE TRANSFORMER 2KVA/230VAC WITH TAPPINGS AT 50% & 86.6% AIR COOLED

Minimum Order Quantity : 1 Piece

Usage : SINGLE PHASE TRANSFORMER 2KVA/230VAC WITH TAPPINGS AT 50% & 86.6% AIR COOLED

Product Type : SINGLE PHASE TRANSFORMER 2KVA/230VAC WITH TAPPINGS AT 50% & 86.6% AIR COOLED

Application : SINGLE PHASE TRANSFORMER 2KVA/230VAC WITH TAPPINGS AT 50% & 86.6% AIR COOLED

JONES CHOPPER

JONES CHOPPER

Minimum Order Quantity : 1 Piece

Usage : JONES CHOPPER

Product Type : JONES CHOPPER

Application : JONES CHOPPER

RESISTANCE IN SERIES & PARALLEL APPARATUS WITH ALUMINUM PANEL & SQUARE METERS

RESISTANCE IN SERIES & PARALLEL APPARATUS WITH ALUMINUM PANEL & SQUARE METERS