trusted seller
STARTING AND REVERSING OF DC SHUNT MOTOR
STARTING AND REVERSING OF DC SHUNT MOTOR
STARTING AND REVERSING OF DC SHUNT MOTOR
STARTING AND REVERSING OF DC SHUNT MOTOR

STARTING AND REVERSING OF DC SHUNT MOTOR

MOQ : 1 Piece

STARTING AND REVERSING OF DC SHUNT MOTOR Specification

  • Display Type
  • Analog/Optional Digital Panel Meter
  • Operating Voltage
  • 230 V AC
  • Number of Specimens
  • Single (One Motor per Test)
  • Test Range
  • 0 to Rated Speed/Reversal
  • Frequency
  • 50 Hz
  • Power Supply
  • 230 V AC, 50 Hz
  • Humidity
  • Up to 90% RH
  • Equipment Type
  • STARTING AND REVERSING OF DC SHUNT MOTOR
  • Temperature
  • 0C to 50C
  • Mounting Type
  • Benchtop/Tabletop
  • Application
  • STARTING AND REVERSING OF DC SHUNT MOTOR
  • Specimen Size
  • Standard Lab Bench Size DC Shunt Motor
  • Response Time
  • Instantaneous (Mechanical/Electromagnetic Relay)
  • Product Type
  • STARTING AND REVERSING OF DC SHUNT MOTOR
  • Features
  • Built-in Starter; Forward/Reverse Control; Protective Devices
  • Interface Type
  • Panel Connections & Terminals
  • Accuracy
  • 1% of Reading
  • Max Height
  • 280 mm (Appx.)
  • Measuring Range
  • 0-300 V, 0-10 A (Typical Panel Meters)
  • Automation Grade
  • Semi-Automatic
  • Resolution
  • 0.1 V / 0.01 A
  • Usage
  • For Laboratory & Educational Training Purposes
  • Capacity
  • 1/2 HP - 1 HP
  • Machine Weight
  • Approx. 20 kg
  • Test Speed
  • 1500 RPM (Standard) / Variable with Voltage Control
  • Control Mode
  • Manual & Automatic with Reversing Switch
  • Motor Type
  • DC Shunt Motor
  • Panel Indication
  • On/Off, Reverse/Forward LED Indicators
  • Educational Use
  • Suitable for Polytechnic, Engineering Colleges & Vocational Training
  • Connection Diagram
  • Laminated and Printed on Front Panel
  • Wiring Diagram
  • Integrated on Panel
  • Reversal Mechanism
  • DPDT Switch or Contactor Controlled
  • Dimensions
  • 350 mm x 250 mm x 280 mm (LxWxH)
  • Equipment Type
  • Electrical Machine Trainer
  • Build Material
  • Powder Coated MS Cabinet
  • Starter Type
  • 3-Point Starter with No-Volt & Overload Protection
  • Motor Speed Control
  • Variable via Rheostat
  • Phase
  • Single Phase Operation
  • Insulation Class
  • Class B or Higher
  • Protection
  • Overload and No-Volt Protection
  • Accessories Included
  • Connecting Leads, Load Bank, User Manual
 

STARTING AND REVERSING OF DC SHUNT MOTOR Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About STARTING AND REVERSING OF DC SHUNT MOTOR

Starting and Reversing of DC Shunt Motor.

Suppliedwith DC Shunt Motor 1HP & ControlPanel fitted with Necessary Meters, Fixed Voltage DC Source and 3 Point DCStarter

OptionalAccessories

Variac 4Amps Single Phase



Designed for Effective Learning

This electrical machine trainer provides hands-on experience with DC shunt motor starting and reversal, making it ideal for students pursuing electrical engineering or vocational training. With practical components, such as a 3-point starter and clear on-panel wiring diagram, learners can visualize and comprehend key concepts effectively.


Enhanced Safety Features

Safety is prioritized through built-in no-volt and overload protection mechanisms. The powder-coated MS cabinet, along with instantaneous mechanical relays, ensures robust operation and user safety during experiments, even under variable laboratory conditions.


User-Friendly Operation

Control forward and reverse motion easily using a DPDT switch or contactor system. Panel LEDs indicate device status at a glance, while variable speed adjustment is achieved with a motor rheostat. Manual and automatic control modes allow flexibility for diverse educational demonstrations.

FAQ's of STARTING AND REVERSING OF DC SHUNT MOTOR:


Q: How does the Starting and Reversing of DC Shunt Motor Trainer operate?

A: The equipment uses a 3-point starter for safe initiation of the DC shunt motor, allowing users to start, stop, and reverse the motor using a DPDT switch or contactor. The speed can be varied with a rheostat, and operation is monitored through analog or digital panel meters and indicator LEDs.

Q: What protective features are included in this trainer?

A: The trainer incorporates overload and no-volt protection through its 3-point starter and relay mechanisms. These features safeguard the motor and user during practical experiments by automatically disconnecting power under unsafe conditions.

Q: When is it suitable to use this equipment during a curriculum?

A: This trainer is best utilized during laboratory sessions in polytechnic, engineering, or vocational courses related to electrical machines, motor control, or power electronics, offering hands-on experiments in DC motor starting, speed control, and reversal.

Q: Where can the trainer be installed or used?

A: Designed for benchtop or tabletop use, the equipment fits standard laboratory settings, academic workshops, and technical training institutions. Its compact size and rugged build make it portable and suitable for classroom demonstrations.

Q: What is the process for reversing the DC shunt motor's direction?

A: Reversing the motor involves actuating the DPDT switch or contactor on the control panel, which swaps the field or armature connections. The change is indicated by forward/reverse LEDs, allowing students to observe real-time operational changes.

Q: How do the wiring diagram and instructions aid users?

A: A laminated and printed connection diagram is integrated on the front panel, streamlining cable management and ensuring correct wiring. The user manual provides step-by-step procedures, enhancing safety and facilitating independent learning.

Q: What are the educational benefits of using this trainer?

A: The trainer bridges theoretical knowledge with real-world practice, helping students understand DC motor fundamentals, starter operations, and protection schemes. It also develops practical skills essential for industrial and laboratory roles in electrical engineering.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

Microcontroller 8051/2 Development Kit

Microcontroller 8051/2 Development Kit

Price 1000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Industrial

Application : electrical teaching

Product Type : Microcontroller 8051/2 Development Kit

Voltage : 12 Volt (v)

RIPPLE FACTOR APPARATUS WITH BAKELITE PANEL & ROUND METERS (HALF WAVE,FULL WAVE AND BRIDGE RECTIFIER)

RIPPLE FACTOR APPARATUS WITH BAKELITE PANEL & ROUND METERS (HALF WAVE,FULL WAVE AND BRIDGE RECTIFIER)

Price 1000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : lab

Application : lab

Product Type : RIPPLE FACTOR APPARATUS WITH BAKELITE PANEL & ROUND METERS (HALF WAVE,FULL WAVE AND BRIDGE RECTIFIER)

Voltage : 220 Volt (v)

DETERMINE THE FOCAL LENGTH OF TWO LENSES BY NODAL SLIDE AND LOCATE THE POSITION OF CARDINAL POINTS (COMPLETE SETUP)

DETERMINE THE FOCAL LENGTH OF TWO LENSES BY NODAL SLIDE AND LOCATE THE POSITION OF CARDINAL POINTS (COMPLETE SETUP)

Minimum Order Quantity : 1 Piece

Usage : DETERMINE THE FOCAL LENGTH OF TWO LENSES BY NODAL SLIDE AND LOCATE THE POSITION OF CARDINAL POINTS (COMPLETE SETUP)

Application : DETERMINE THE FOCAL LENGTH OF TWO LENSES BY NODAL SLIDE AND LOCATE THE POSITION OF CARDINAL POINTS (COMPLETE SETUP)

Product Type : DETERMINE THE FOCAL LENGTH OF TWO LENSES BY NODAL SLIDE AND LOCATE THE POSITION OF CARDINAL POINTS (COMPLETE SETUP)

DELTA, ADAPTIVE DELTA AND DELTA SIGMA MODULATION & DEMODULATION

DELTA, ADAPTIVE DELTA AND DELTA SIGMA MODULATION & DEMODULATION

Minimum Order Quantity : 1 Piece

Usage : DELTA, ADAPTIVE DELTA AND DELTA SIGMA MODULATION & DEMODULATION

Application : DELTA, ADAPTIVE DELTA AND DELTA SIGMA MODULATION & DEMODULATION

Product Type : DELTA, ADAPTIVE DELTA AND DELTA SIGMA MODULATION & DEMODULATION



Back to top