trusted seller
Radial Blade Pump
Radial Blade Pump
Radial Blade Pump
Radial Blade Pump
Radial Blade Pump
Radial Blade Pump

Radial Blade Pump

Price 10 INR/ Piece

MOQ : 1 , , Piece

Radial Blade Pump Specification

  • Measurement Range
  • Up to 100 lph
  • Temperature Range
  • 0 to 100C
  • Application
  • Applied Mechanics Lab Equipments
  • Power Source
  • Electric
  • Feature
  • Corrosion Resistant, Easy Operation, Durable
  • Frequency
  • 50 Hz
  • Core Components
  • Pump, Motor, Glass Tank, Valves, Flow Meter
  • Automation Grade
  • Manual
  • Voltage
  • 220 V AC
  • Usage
  • Applied Mechanics Lab Equipments
  • Model No
  • RE-06
  • Accuracy
  • 1%
  • Product Type
  • Radial Turbine Pump
  • Equipment Materials
  • Stainless Steel, Mild Steel, Glass
  • Type
  • Radial Blade Pump
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • 1100 x 600 x 850 mm
  • Weight
  • Approx. 45 kg
 

Radial Blade Pump Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Radial Blade Pump

Radial Turbine Pump



It is an all metallic properly constructed model, the impeller is surrounded by a number of stationary vanes one side is covered with plexi glass showing internal details, complete mounted on cast iron base. Height 300 mm approximately,



High Precision and Durability

Equipped with a stainless steel impeller and a corrosion-resistant build, this radial blade pump guarantees long-term reliability. The use of high-quality materials such as mild steel, stainless steel, and glass ensures optimal performance, even in rigorous lab applications. The pump is designed in accordance with IS/ISO 4064 standards, making it suitable for consistent, accurate measurements.


User-Friendly Laboratory Equipment

The model RE-06 operates at 2800 rpm, providing efficient fluid transfer for laboratory procedures. Its glass tank and clear analog display enable easy monitoring of water flow and status. Manual operation and straightforward controls are tailored for educational environments, allowing students and technicians to perform demonstrations and experiments without difficulty.

FAQs of Radial Blade Pump:


Q: How is the Radial Blade Pump installed and set up in an applied mechanics laboratory?

A: To install the Radial Blade Pump, position it securely on a flat surface, ensuring its dimensions1100 x 600 x 850 mmfit the allocated space. Connect the pump to a 220 V AC power supply, and attach the glass tank, flow meter, and necessary valves as per the labs experiment requirements. Verify all connections, then prime the system before operating to ensure accurate measurement.

Q: What materials are used in the pumps construction, and how do they enhance durability?

A: The pump is primarily constructed with stainless steel for the impeller and wetted parts, while mild steel and glass comprise the housing and tank. These materials offer excellent corrosion resistance, mechanical strength, and visibility, contributing to the pumps long-lasting performance and suitability for laboratory usage.

Q: When should the pump be used in lab experiments, and what is its measurement range?

A: Utilize the pump for fluid mechanics and hydraulic experiments when precise water flow rates up to 100 liters per hour are required. The equipment is ideal for demonstrations and practical applications within the temperature range of 0 to 100C, supporting experiments aligned with IS/ISO 4064 standards.

Q: Where is the pump most effectively used in an educational setting?

A: The pump is best deployed in applied mechanics laboratories in academic institutions, research centers, or training facilities. Its design and manual operation make it perfect for student demonstrations, hands-on exercises, and performance testing within controlled laboratory environments.

Q: What is the process for measuring flow rate with this pump?

A: To measure flow rate, start the pump using its manual controls, observe the analog display and flow meter for readings, and adjust the valves to achieve the desired output. The system ensures measurement accuracy within 1%, allowing precise data capture for laboratory records and analyses.

Q: How does using this pump benefit laboratory users?

A: Lab users benefit from the pumps ease of operation, corrosion resistance, and accurate fluid measurement. Its robust assembly and compliance with IS/ISO 4064 standards help provide reliable experimental results and foster a better understanding of fluid mechanics principles.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Applied Mechanics Lab Equipments Category

Law Of Conservation Of Mass

Law Of Conservation Of Mass

Price 10 INR / Piece

Minimum Order Quantity : 10 Pieces

Usage : Applied Mechanics Lab Equipments

Power Source : Manual (No electricity required)

Measurement Range : 0 to 1000 grams

Combined Inclined Plane and Friction Slide

Combined Inclined Plane and Friction Slide

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Applied Mechanics Lab Equipments

Measurement Range : Up to 45degree inclination

Bell Crank Lever

Bell Crank Lever

Price 100 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Applied Mechanics Lab Equipments

Power Source : Manual

Measurement Range : As per lab experiment requirements

Screw Efficiency Apparatus

Screw Efficiency Apparatus

Minimum Order Quantity : 1 Piece

Usage : Laboratory

Power Source : Manual

Material : Mild Steel



Back to top