trusted seller
Plate Girder Bridge
Plate Girder Bridge

Plate Girder Bridge

Price 100 INR/ Piece

MOQ : 1 , , Piece

Plate Girder Bridge Specification

  • Operating Voltage
  • N/A (manual model, or 220V AC for instrumented models)
  • Specimen Size
  • Customizable (standard sizes: spans 1 m to 5 m for lab scale)
  • Application
  • Civil Engineering Lab Equipments
  • Max Height
  • Varies (typically 0.2 to 1 m for lab models)
  • Product Type
  • Plate Girder Bridge
  • Interface Type
  • N/A (no interface; optional data acquisition if specified)
  • Number of Specimens
  • Single (as per bridge section/model supplied)
  • Accuracy
  • 0.5% (for instrumentation, if provided)
  • Mounting Type
  • Bench-mounted or floor-mounted
  • Humidity
  • 10% to 90% non-condensing (installation environment)
  • Response Time
  • Instantaneous (bridge structures)
  • Resolution
  • 0.1 mm (for deflection, when instrumented)
  • Power Supply
  • N/A (unless equipped with instrumentation)
  • Temperature
  • -10C to 55C (operational limits)
  • Measuring Range
  • Depends on design (load, deflection etc.)
  • Display Type
  • Analog/Digital (if instrumented)
  • Automation Grade
  • Manual/Optional Semi-automatic (for loading systems)
  • Hardness
  • As per structural steel grade (e.g., 155-200 HB)
  • Features
  • Modular construction, interchangeable parts, corrosion-resistant finish
  • Test Range
  • Depends on design/load capacity
  • Usage
  • Civil Engineering Lab Equipments
  • Capacity
  • Customized, typically up to 200 kN (lab models)
  • Machine Weight
  • Varies depending on span and design (typically 2-10 tons)
  • Test Speed
  • N/A (static bridge structure, not applicable)
  • Test Width
  • Varies (customizable as per requirement)
  • Control Mode
  • Manual/Electromechanical (for load application in laboratory models)
 

Plate Girder Bridge Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Cheque, Letter of Credit (L/C), Cash in Advance (CID), Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Plate Girder Bridge

Plate Girder Bridge:
A properly constructed model of usual construction showing abutment, wing walls all necessary transverse and longitudinal sleepers and track of rail rod. The model is about 135 cm long and Is made of metallic and wooden parts.....

Features:

  •     Die-cast girders and track supports
  •     Highly detailed
  •     Accurately detailed bridge track
  •     Add-on kit available for multiple track mainlines
  •     Tie strip has UV additive for outside use
  •     Track 18" in length; Girders 15" in length; height of girders: 1.8"
  •     Available in both 2-Rail and 3-Rail versions

 



Versatile Plate Girder Bridge for Engineering Labs

Ideal for teaching and research, this Plate Girder Bridge accommodates custom span lengths and load capacities up to 200 kN for laboratory experiments. Its modular design simplifies assembly and allows convenient modification, perfect for hands-on demonstrations and comparative studies. The corrosion-resistant finish ensures longevity in varied environmental conditions, whether mounted on benches or floors within academic institutions. Optional instrumentation provides precise measurement of load and deflection, supporting up-to-date training in structural analysis.


Customizable Load Application and Instrumentation

Select manual screw jack or hydraulic loading systems to suit your testing requirements. Precision instrumentssuch as dial gauges and strain gaugescan be added for comprehensive analysis. Data collection is available through analog or digital displays, ensuring adaptability for both basic and advanced coursework or research. No power supply is required unless instrumentation is included, making this bridge exceptionally flexible for diverse lab setups and educational scopes.


Built for Durability and Compliance

Manufactured according to Indian Standards (IS), ASTM, or tailored specifications, the Plate Girder Bridge is engineered for strength and reliability. Its structural steel construction ensures high hardness and stability, while the protective finish guards against corrosion. Easily transported in customized wooden crates, this equipment is supported by a 12-month warranty, allowing educators and researchers confidence in quality and ongoing support.

FAQs of Plate Girder Bridge:


Q: How is the Plate Girder Bridge assembled in a civil engineering laboratory?

A: The Plate Girder Bridge is supplied as a modular kit requiring assembly. Components are designed to be easily fitted together, either bench-mounted or floor-mounted, using standard lab tools. Assembly instructions are provided to guide lab staff or students through the process.

Q: What are the benefits of using a powder-coated or painted finish on the Plate Girder Bridge?

A: The powder-coated or painted finish offers excellent resistance to corrosion, extending the service life of the bridge model. This protective layer is particularly effective in laboratory environments that may experience varying humidity and temperature conditions.

Q: When is manual or hydraulic loading recommended for laboratory testing?

A: Manual loading using a screw jack is suitable for demonstrations and low-load applications, while hydraulic loading is recommended for higher load scenarios or when precise control is required during experiments. Both methods are compatible with optional instrumentation for detailed measurement.

Q: Where can customization be applied to the Plate Girder Bridge models?

A: Customization is available for bridge span (15 meters or as specified), color preference (industrial grey/blue or custom), load capacity, instrumentation type, and packaging. These options ensure the bridge meets specific educational, research, or testing needs.

Q: What process is followed for instrumentation integration?

A: Instrumentation such as dial gauges, strain gauges, and load cells can be optionally integrated during assembly. These are positioned at designated locations on the bridge structure to measure load and deflection, with output displayed through analog or digital devices for real-time analysis.

Q: How is the maximum load capacity determined for a Plate Girder Bridge lab model?

A: The maximum load capacity, up to 200 kN for lab models, is determined based on the bridges span, design, material grade, and intended application. Custom calculations and compliance with IS or ASTM standards ensure safe and reliable operation during laboratory tests.

Q: What are the main usage and benefits of Plate Girder Bridge equipment in civil engineering labs?

A: This equipment allows students and researchers to study structural behavior under controlled loading conditions. With modular assembly, interchangeable parts, and accurate instrumentation, the Plate Girder Bridge is invaluable for hands-on learning, practical demonstrations, and structural analysis experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Civil Engineering Lab Equipments Category

Wheel Tracking

Wheel Tracking

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Civil Engineering Lab Equipments

Power Supply : 220V AC, 50 Hz

Features : Automatic data recording, Programmable cycles, Heating chamber

Mounting Type : Floor standing

Ductilometer The Elastic Recovery

Ductilometer The Elastic Recovery

Price 100 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Civil Engineering Lab Equipments

Power Supply : 230V AC, 50 Hz

Features : Digital control, Automatic stop, Temperature control, Multisample testing

Mounting Type : Benchtop

MORTAR MIXER

MORTAR MIXER

Price 100 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Civil Engineering Lab Equipments

Power Supply : 230 V AC, 1 Phase, 50 Hz

Features : Robust Construction, Planetary & Beater Movement, Stainless Steel Bowl

Mounting Type : Floor / Table Mounted

CONCRETE COVER METER

CONCRETE COVER METER

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric



Back to top