Pensky Marten Flash Point Apparatus for testing Specification

  • Port Size
  • Standard test cup opening
  • Display Type
  • Analog / Digital, depends on model
  • Application
  • Petroleum Testing Instruments
  • Response Time
  • Immediate (visual ignition detection)
  • Specimen Size
  • 75 ml (test cup)
  • Operating Voltage
  • 230 V AC
  • Measuring Range
  • Up to 370C
  • Temperature
  • Ambient to 110C (Open Type), up to 370C (Closed Type)
  • Resolution
  • 0.5C
  • Hardness
  • Corrosion-resistant brass and stainless steel
  • Power Supply
  • 230 V AC, 50 Hz
  • Number of Specimens
  • 1 per test
  • Max Height
  • 320 mm
  • Test Range
  • Room temperature to 370C
  • Features
  • Fitted with stirrer, flame device, and insulated handle
  • Gas Pressure
  • Natural gas/LPG at low pressure (for flames)
  • Frequency
  • 50 Hz
  • Usage
  • Petroleum Testing Instruments
  • Humidity
  • Up to 80% RH non-condensing
  • Equipment Type
  • Laboratory Testing Apparatus
  • Mounting Type
  • Bench-top
  • Product Type
  • Pensky Marten Flash Point Apparatus
  • Automation Grade
  • Manual/Semi-automatic
  • Interface Type
  • Manual
  • Accuracy
  • 1C
  • Capacity
  • Single test cup
  • Machine Weight
  • 8 kg (approx)
  • Test Speed
  • Manual operation
  • Test Width
  • Standard cup diameter: 55 mm
  • Test Stroke
  • Manual stirrer movement
  • Control Mode
  • Semi-automatic
 

Pensky Marten Flash Point Apparatus for testing Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Pensky Marten Flash Point Apparatus for testing

Pensky Marten Flash Point Apparatus

It is may be defined as the flash point of petroleum products and mixture having a flash point below 49 degree F (120 degree F). The apparatus consists of cast iron stave fitted with a polished brass cover a brass cup with cover which contains the test flame arrangement stirrer (hand operated) and heating arrangement for electricity heated model a rectangular heater with an energy regulator fitted in a box.

Technical Specification

  • Pen sky Martens Flash Point Apparatus electrical heated with Energy Regulator Oil Test Jet
  • Pen sky Martens Flash Point Apparatus electrical heated with Concealed Hot Plate & Oil Test Jet
  • Pen sky Martens Flash Point Apparatus with Energy Regulator Geared Motor Stirrer (120 R.P.M) Oil Test Jet
  • Pen sky Martens Flash Point Apparatus with Electronic Temp. Indicator and Regulator Oil Test Jet
  • Pen sky Martens Flash Point Apparatus with Electronic VOLTAGE VARIAC and digital temp. Indicator and constant speed stirring Device Oil Test Jet
  • Semi Automatic Flash Point Apparatus with Electronic Temp. Controller, Automatic Dipping cycle with Remote Control Oil Test Jet and Gas Test Jet
  • Fully Automatic Flash Point apparatus Micro Controlled based with LCD Display Temp. Range from 80C to 350oC.

 

Optional Accessories

  • Low Range Thermometer 
  • High Range Thermometer 
  • Polish Wooden case
  • Spare cup with handle
  • Spare Cover Assemble
  • Spare Nichrome Heating element
  • Spare Concealed Hot Plate with housing

 



Dual Testing Methods for Reliable Results

The Pensky Marten Apparatus supports both open and closed cup testing to deliver comprehensive flash point data. This flexibility lets you select the most suitable method for different petroleum-based samples, enhancing accuracy and compliance with testing standards in diverse laboratory applications.


Precision Engineering for Laboratory Safety

Featuring a corrosion-resistant brass test cup and a stainless steel housing, this apparatus also includes thermally insulated handles and bases. The protective flame cover and secure manual operation make it both robust and safe, while the fitted stirrer and regulator ensure ease of use and reliable results.

FAQs of Pensky Marten Flash Point Apparatus for testing:


Q: How does the Pensky Marten Flash Point Apparatus operate?

A: The apparatus operates using an electric heater for controlled sample heating, a manual stirrer to homogenize the sample at 60 2 RPM, and a test flame from a gas burner for ignition. Both open and closed cup test modes are available, enabling precise flash point determination as per IS and ASTM specifications.

Q: What applications is this apparatus best suited for?

A: It is specifically designed for testing petroleum and allied products in laboratory settings. Typical users include quality control labs, refineries, research institutions, and manufacturing facilities needing reliable flash point measurements.

Q: When should the open cup vs. closed cup test method be used?

A: Open cup is generally used for samples susceptible to atmospheric influences or where vapors might escape easily, while closed cup testing provides more controlled, reproducible results for volatile substances. Choice depends on sample properties and compliance requirements.

Q: Where should the Pensky Marten Apparatus be installed and operated?

A: It should be installed on a stable laboratory bench in an environment within a temperature range of ambient to 110C for open cup and up to 370C for closed cup tests. Ensure power supply of 230 V AC, 50 Hz, and adequate ventilation when operating the gas burner.

Q: What safety features are integrated into the design?

A: For user safety, the device features a protective flame cover, thermally insulated handle and base, and robust stainless steel and brass construction. These measures minimize burn risk and ensure safe handling during operation.

Q: What is the process for conducting a flash point test with this equipment?

A: First, pour 75 ml of the sample into the brass test cup and secure the fitted cover. Heat gradually using the regulated electric heater, stirring the sample manually. Apply the test flame at regular intervals and observe ignition. Record the temperature at immediate visual detection of the flash.

Q: What are the key benefits of using this apparatus?

A: Key benefits include compliance with international standards, high accuracy (1C), dual testing modes, robust build quality, immediate response time for ignition detection, and enhanced safety features, making it ideal for precise flash point measurement in petroleum laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Cast Aluminum Corrosion Test Apparatus

Cast Aluminum Corrosion Test Apparatus

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Frequency : 50 Hz

Power Supply : 230V AC, 50Hz

Automation Grade : Manual

Cloud and Pour Test Apparatus

Cloud and Pour Test Apparatus

Price 100 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Frequency : 50 Hz

Power Supply : 230 V AC, 50 Hz, Single Phase

Automation Grade : Manual

Oxidation Stability Test Apparatus

Oxidation Stability Test Apparatus

Price 100 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Frequency : 50 Hz

Power Supply : 230V AC, 50 Hz

Automation Grade : SemiAutomatic

Cloud Point and Pour Point Apparatus

Cloud Point and Pour Point Apparatus

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Frequency : 50 Hz

Power Supply : 230V AC, 50 Hz

Automation Grade : Manual



Back to top