trusted seller
PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST
PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST
PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST
PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST

PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST

MOQ : 1 Piece

PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST Specification

  • Application
  • Determining losses and parameters (OC/SC test) of single-phase transformers
  • Features
  • Includes test transformer, meters, switches, protective relays, & test leads
  • Specimen Size
  • Up to 12 x 10 x 12 / customizable clamp
  • Interface Type
  • Banana terminals, safety connectors
  • Measuring Range
  • Voltage: 0-500V, Current: 0-5A, Power: 0-2.5kW
  • Automation Grade
  • Semi-automatic/Manual
  • Response Time
  • <1 sec
  • Mounting Type
  • Table-top/Lab bench
  • Product Type
  • PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST
  • Operating Voltage
  • 230V AC mains
  • Equipment Type
  • PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST
  • Port Size
  • Standard electrical ports for test connections
  • Frequency
  • 50 Hz
  • Max Height
  • 30 cm (setup only, transformer dependent)
  • Test Range
  • Suitable for transformers up to 2 kVA
  • Accuracy
  • 1% of reading
  • Display Type
  • Digital LCD/LED meter display
  • Number of Specimens
  • 1 transformer per test
  • Humidity
  • Up to 85% RH (non-condensing)
  • Power Supply
  • 230 V AC, 50 Hz, single phase
  • Resolution
  • Voltage: 0.1V, Current: 0.01A, Power: 0.01W
  • Temperature
  • Operating range 0C to 50C
  • Usage
  • Educational laboratory experiments, transformer loss measurement
  • Capacity
  • 1 kVA (standard model), up to 2 kVA optional
  • Machine Weight
  • 15 - 25 kg (approx, depending on setup)
  • Test Speed
  • OC & SC Test performed at rated frequency, speed not applicable
  • Control Mode
  • Manual/Automatic with digital panel
  • Accessories Provided
  • Test leads, crocodile clips, operation manual
  • Panel Finish
  • Powder-coated, anti-corrosive
  • Insulation Resistance Test
  • Provision for insulation resistance check
  • Program Capability
  • Optional software for data logging (on request)
  • Safety Protection
  • Circuit breaker, overcurrent protection, fuses
  • Service Support
  • 1 year warranty, technical support available
  • Calibration
  • Factory calibrated, calibration certificate provided
  • Included Meters
  • Voltmeter, Ammeter, Wattmeter (digital)
  • Test Procedures Supported
  • Open Circuit (OC) Test, Short Circuit (SC) Test
  • Mobility
  • Portable (carry handles provided)
  • Cooling Type
  • Transformer: Air cooled
  • Storage Conditions
  • -10C to 55C, dry locations
 

PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST

Parameter and Losses in a Single Phase Transformer by OC and SC Test

Control panel fitted with Necessary Meters & builtin 1 PhaseTransformer 500VA

Accessories for above

Variac 8 Amps Single Phase



Precision Measurement and Safety

Equipped with digital meters, protective relays, and factory calibration, this product ensures reliable transformer parameter testing. Safety is enhanced with overcurrent protection, circuit breakers, and fuses. The insulated and powder-coated panel resists corrosion, while test leads and crocodile clips simplify secure connections during experimentation.


Flexible and User-Friendly Operation

Supporting both manual and semi-automatic modes, this setup caters to diverse test procedures. Users benefit from a digital display for voltage, current, and power, while banana terminals and standard ports guarantee universal compatibility. The portable, table-top design enables easy transport and convenient operation in educational and laboratory settings.


Comprehensive Support and Versatility

Factory calibration, calibration certificate, and an operation manual are provided to streamline deployment. Technical service is covered for one year, with optional software available for data logging and analysis. The system supports a wide range of transformer sizes and environmental conditions, accommodating various testing requirements confidently.

FAQ's of PARAMETER AND LOSSES IN A SINGLE PHASE TRANSFORMER BY OC AND SC TEST:


Q: How do I perform the Open Circuit (OC) and Short Circuit (SC) tests using this equipment?

A: Start by connecting the transformer's primary and secondary as per the operation manual, using the supplied test leads and crocodile clips. For OC test, keep the secondary open and measure parameters from the digital meters; for SC test, the primary is supplied while the secondary is shorted. Record voltage, current, and power for both tests.

Q: What transformer sizes are compatible with this test kit?

A: This equipment is designed to handle single-phase transformers up to 2 kVA. The standard model supports 1 kVA, with options for larger transformers available upon request. The adjustable clamp accommodates specimens up to 12 x 10 x 12 cm.

Q: When should I use the insulation resistance test feature provided?

A: You should perform the insulation resistance test before conducting OC or SC tests. This check ensures that the transformer's insulation is intact and safe for further electrical testing, reducing risk of short circuit or equipment damage.

Q: Where is the ideal environment for operating this testing kit?

A: Operate the equipment in dry indoor locations with temperatures between 0C and 50C, and humidity up to 85% RH (non-condensing). Avoid corrosive or excessively humid conditions to maintain optimal performance and longevity.

Q: What are the benefits of using digital meters with this system?

A: Digital LCD/LED meters offer precise and immediate readouts, increasing accuracy and efficiency in parameter measurement. With 1% reading accuracy and fine resolution, they enhance reliability for transformer diagnostics and educational demonstrations.

Q: How does the safety protection system work during testing?

A: The system integrates circuit breakers, overcurrent protection, and fuses, which automatically disrupt power in case of abnormal electrical conditions, minimizing risk to users and equipment during laboratory experiments.

Q: What technical support is available after purchase?

A: The equipment includes a one-year warranty and access to technical support for troubleshooting and operational guidance. Calibration certificates and comprehensive manuals ensure smooth installation and sustained accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER

SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER

Minimum Order Quantity : 1 Piece

Product Type : SUMPNERS (BACK TO BACK) TEST ON SINGLE PHASE TRANSFORMER

Application : Performance evaluation of single phase transformers

Usage : Educational, Laboratory, Research

Frequency : 50 Hz

Three- Phase Squirrel Cage Motor

Three- Phase Squirrel Cage Motor

Price 1500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Product Type : Three Phase Squirrel Cage Motor

Application : electrical teaching

Usage : Industrial

Frequency : 50 Hertz (HZ)

MILLMANS THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

MILLMANS THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

Price 1000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Product Type : MILLMANS THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

Application : electrical teaching

Usage : Industrial

Frequency : 50 Hertz (HZ)

8257 DMA STUDY CARD

8257 DMA STUDY CARD

Minimum Order Quantity : 1 Piece

Product Type : 8257 DMA STUDY CARD

Application : 8257 DMA STUDY CARD

Usage : 8257 DMA STUDY CARD

Frequency : 50 Hertz (HZ)



Back to top