trusted seller
Oxidation Stability Test Apparatus
Oxidation Stability Test Apparatus

Oxidation Stability Test Apparatus

Price 100 INR/ Piece

MOQ : 1 Piece

Oxidation Stability Test Apparatus Specification

  • Port Size
  • Standard
  • Product Type
  • Oxidation Stability Test Apparatus
  • Response Time
  • Instant
  • Gas Pressure
  • 6 kg/cm (Oxygen) Recommended
  • Temperature
  • Room Temperature up to 150C
  • Application
  • Petroleum Testing Instruments
  • Humidity
  • Ambient
  • Power Supply
  • 230V AC, 50 Hz
  • Interface Type
  • Push Button
  • Usage
  • Petroleum Testing Instruments
  • Display Type
  • Digital Timer
  • Test Range
  • 0-999 minutes
  • Features
  • Stainless Steel Bath, Digital Timer, Safety Shield
  • Measuring Range
  • 0-999 minutes
  • Resolution
  • 1 minute
  • Automation Grade
  • Semi-Automatic
  • Accuracy
  • 1 minute
  • Frequency
  • 50 Hz
  • Specimen Size
  • Standard as per test method
  • Number of Specimens
  • One at a time
  • Mounting Type
  • Bench Top
  • Operating Voltage
  • 230 V
  • Max Height
  • Approx. 45 cm
  • Capacity
  • Single Test Unit
  • Machine Weight
  • Approx. 12 kg
  • Control Mode
  • Digital Control
 

Oxidation Stability Test Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Cheque, Letter of Credit (L/C), Cash in Advance (CID), Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Oxidation Stability Test Apparatus

Oxidation Stability Test Apparatus

Oxidation Stability of Mineral Oil
Construction details

4 nos. test vessel / tube made of borosilicate glass provided with a B -24 cone and having the following dimensions:

Overall Length : 210 +/- 2 mm
External diameter : 26 +/- 0.5 mm
Wall thickness : 1.4 +/- 0.2 mm
Height of head : 28 + /- 2 mm
Oxygen inlet tube Dimensions

External dia : 5.0 +/- 0.4mm
Wall thickness : 0.8 +/- 0.1 mm
The test tube is fitted with a Drechsel head to which is attached the inlet tube which will extended within +/- 2 - 3 mm of the bottom and its end ground at an angle of 60 deg to the horizontal axis as per fig 1 of IS :335 : 1993

One Thermostatic block of following features


It is made of wrought aluminum block provided with four holes to accommodate four test vessels / tubes, provided with a digital PID controller, capable of maintaining the oil temperature at 100.0 +/- 0.5 deg C. 4 nos.

Metallic Copper Catalyst of following dimension


Copper catalysts consist of a wire of non - annealed commercial electrolytic copper of diameter between 1.00 and 1.02 mm. and wire shall have a length of 305 +/- 1.0 mm rolled into a spiral of approx 20 mm external diameter and 50 mm in length.

4 nos. rotameters of following features

These are rotameter type flowmeters with the capacity to measure the flow rate of oxygen in the range 1 +/- 0.1 litre / hour.

Advanced Digital Control for Precision Testing

Equipped with a user-friendly digital timer and push-button interface, this apparatus enables accurate measurement and real-time monitoring of oxidation stability tests. Its semi-automatic operation optimizes both convenience and reliability, ensuring consistent results.


Robust Safety and Construction Features

Engineered with a stainless steel bath and safety shield, the device provides strong durability and optimal operator protection. The over-temperature cut-off mechanism guarantees safe operation while maintaining stable test conditions. The bench-top mounting and compact structure make it adaptable for various laboratory environments.


Compliance and Application Specifics

Designed to meet ASTM D525 and IS:1448 compliance, this apparatus is suited for petroleum testing laboratories and institutions involved in research, quality control, and industrial applications throughout India. Its recommended gas pressure settings and specimen standards assure conformance with established methods.

FAQs of Oxidation Stability Test Apparatus:


Q: How is the Oxidation Stability Test conducted using this apparatus?

A: The test involves placing a standard sample in the borosilicate glass tube, filling the stainless steel bath with a controlled temperature set via the immersion heater, and introducing oxygen at a specified gas pressure. The stirring motor ensures uniform mixing, and the digital timer measures the reaction time accurately until the endpoint.

Q: What are the main benefits of using this apparatus for petroleum testing?

A: This apparatus provides precise, repeatable results due to its digital controls and accurate timing (1 minute). The robust safety features help protect operators, while compliance with ASTM D525/IS:1448 ensures results are widely accepted in industry, quality control, and regulatory settings.

Q: When should the oxidation stability test be performed?

A: The test is typically conducted during the quality assessment phase of petroleum product development or prior to release, as required by industry standards or customer specifications, to determine the products resistance to oxidation.

Q: Where is this equipment best utilized?

A: This apparatus is ideal for laboratory settings within petroleum refineries, research institutions, quality control labs, and independent testing agencies engaged in evaluating fuel and lubricant stability.

Q: What process does the apparatus follow for safety during operation?

A: It employs several safety mechanisms, including a safety shield to protect against glass breakage, over-temperature cut-off to prevent overheating, and a sturdy stainless steel construction to contain samples securely during heating and stirring.

Q: How is the testing procedure monitored and controlled?

A: The instrument provides digital control over timing and bath temperature, and the status is viewable in real time on the digital timer display. Operators can make adjustments using the push-button interface to ensure the test meets method specifications.

Q: What are the usage guidelines for optimal performance?

A: Ensure the apparatus is mounted securely on a bench-top, connect to a 230V AC power source, and use only standard glassware and oxygen pressure as per guidelines. Regularly monitor safety features and bath temperature during operation for reliable test results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Softening Point Apparatus Ring and Ball Apparatus

Softening Point Apparatus Ring and Ball Apparatus

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 1C

Specimen Size : 10 mm internal diameter x 2.5 mm deep (Ring size as per IS:1205)

Number of Specimens : 2 (Simultaneous testing with two rings)

Mounting Type : Table Top

Ramsbottom Carbon Residue Apparatus

Ramsbottom Carbon Residue Apparatus

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : Complies with ASTM D524 / IS 1448 (P8): 0.5%

Specimen Size : 5 grams (standard test method)

Number of Specimens : 1 per test

Mounting Type : Benchtop

Engler Viscometer Apparatus

Engler Viscometer Apparatus

Price 100 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 0.1 Engler unit

Specimen Size : 50 ml

Number of Specimens : Single specimen per test

Mounting Type : Benchtop

Cloud Point and Pour Point Apparatus

Cloud Point and Pour Point Apparatus

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 1C

Specimen Size : 50 ml

Number of Specimens : 2 tests simultaneously

Mounting Type : Benchtop



Back to top