trusted seller
OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR

OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR

MOQ : 1 Piece

OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR Specification

  • Product Type
  • OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
  • Power Supply
  • 230V AC, 50Hz
  • Application
  • OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
  • Accuracy
  • 1% of FS
  • Specimen Size
  • Shunt Generator, 1 kW
  • Number of Specimens
  • Single (Generator under test)
  • Response Time
  • Instantaneous, less than 2s
  • Max Height
  • 500 mm
  • Features
  • Heavy base, interlocked terminals, protection fuses
  • Frequency
  • 50 Hz
  • Measuring Range
  • 0 to 300 V (Voltmeter), 0 to 10 A (Ammeter)
  • Humidity
  • Up to 85% RH (non-condensing)
  • Test Range
  • 0 to 250 V (Open Circuit), 0 to 8 A (Load Test)
  • Port Size
  • Standard terminal posts
  • Interface Type
  • Panel mounted meters and terminals
  • Operating Voltage
  • 230V AC
  • Automation Grade
  • Manual
  • Resolution
  • 0.1 V, 0.01 A
  • Temperature
  • 0C to 50C
  • Equipment Type
  • OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR
  • Mounting Type
  • Bench-top
  • Display Type
  • Analog or Digital meters
  • Usage
  • Educational laboratory, practical demonstration
  • Capacity
  • 1 kW
  • Machine Weight
  • Approx. 80 kg
  • Test Speed
  • 1500 rpm
  • Test Width
  • 300 mm
  • Test Stroke
  • Variable, up to 100 mm
  • Control Mode
  • Manual
  • Field Rheostat
  • Provided for excitation control
  • Base Material
  • MS powder coated
  • Protection
  • Inbuilt overload and short circuit protection
  • Coupling Type
  • Flexible coupling with DC motor
  • Cooling Type
  • Air cooled
  • Rotor Diameter
  • 150 mm
  • Loading Arrangement
  • Resistive load bank (wire wound) included
  • Accessories Supplied
  • Connecting wires, user manual, data sheet
 

OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR

OCC and Load Charcteristics of DC Shunt Generator

Suppliedwith DC Shunt Motor 1HP Coupled with DC Shunt Generator 0.7KW fitted with Proximity Sensor & ControlPanel fitted with Necessary Meters, Fixed Voltage DC Source, 3 Point DC Starter& Digital RPM Meter

Accessoriesfor above

Resistivelamp Load 500W in 5 steps

OptionalAccessories

Variac 4Amps Single Phase



Precision Engineering for Reliable Educational Use

Specially built for laboratory and classroom environments, this equipment combines a 1 kW DC shunt generator with a flexible test system and multiple safety features. Its bench-top design, durable powder-coated body, and built-in protections guarantee longevity and operational safety. The manual interface offers direct, hands-on experience in examining open-circuit and load characteristics.


Comprehensive Control and Measurement

Users benefit from precise control of excitation through a field rheostat and straightforward loading using a wire-wound resistive load bank. Panel-integrated analog or digital meters provide quick and accurate readings, with a high degree of measurement accuracy (1% FS) and fast response times, ensuring students and technicians capture real-time results during practical sessions.

FAQ's of OCC AND LOAD CHARCTERISTICS OF DC SHUNT GENERATOR:


Q: How do I operate the OCC and Load Characteristics of DC Shunt Generator in the laboratory?

A: Begin by connecting the supplied wires as per the user manual, then manually control excitation with the field rheostat. Apply loads using the included resistive load bank and monitor performance using panel-mounted meters. Ensure the system is powered by a 230V AC supply and follow safety instructions for reliable operation.

Q: What protective features are included in this generator setup?

A: This system includes inbuilt overload and short-circuit protection via fuses and interlocked terminals to prevent accidental damage, safeguarding both equipment and users during practical demonstrations.

Q: Where can I view the voltage and current during testing?

A: Voltage and current readings are displayed on the analog or digital panel-mounted meters. These are designed for easy visibility and provide real-time, accurate measurements for precise data collection during experiments.

Q: When should the field rheostat be adjusted during testing?

A: Adjust the field rheostat whenever you wish to change the excitation current, such as when plotting open-circuit characteristics or observing how excitation affects output under various load conditions.

Q: What is the process for conducting a load test with this equipment?

A: First, ensure the generator is connected and rotating at 1500 rpm. Adjust the field rheostat for desired excitation, then gradually apply resistive load using the load bank and observe the generator's response on the meters. Record the voltage and current at each load step for analysis.

Q: What are the primary benefits of using this educational setup for OCC and load characteristic experiments?

A: This equipment offers safe, precise, and hands-on experimentation, enhancing theoretical understanding with real-world data. Its robust design, protective features, and accurate measurement instruments make it ideal for repeated use in rigorous educational settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

SINGLE PHASE ENERGY METER WITH PHANTOM LOADING

SINGLE PHASE ENERGY METER WITH PHANTOM LOADING

Minimum Order Quantity : 1 Piece

Usage : For Energy Meter Calibration and Testing

Product Type : SINGLE PHASE ENERGY METER WITH PHANTOM LOADING

Application : SINGLE PHASE ENERGY METER WITH PHANTOM LOADING

Frequency : 50Hz Hertz (HZ)

Voltage : 220 Volt (v)

4/8 BIT ANALOG TO DIGITAL CONVERTER

4/8 BIT ANALOG TO DIGITAL CONVERTER

Minimum Order Quantity : 1 Piece

Usage : Industrial

Frequency : 50 Hertz (HZ)

Voltage : 220 Volt (v)

DIELECTRIC CONSTANT APPARATUS (SOLID & LIQUID)

DIELECTRIC CONSTANT APPARATUS (SOLID & LIQUID)

Minimum Order Quantity : 1 Piece

Usage : DIELECTRIC CONSTANT APPARATUS (SOLID & LIQUID)

Product Type : DIELECTRIC CONSTANT APPARATUS (SOLID & LIQUID)

Application : DIELECTRIC CONSTANT APPARATUS (SOLID & LIQUID)

OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR

OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR

Minimum Order Quantity : 1 Piece

Usage : OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR

Product Type : OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR

Application : OPERATIONAL AMPLIFIER AS VOLTAGE COMPARATOR



Back to top