trusted seller
OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR

OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR

MOQ : 1 Piece

OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR Specification

  • Accuracy
  • 1.5%
  • Equipment Type
  • OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
  • Max Height
  • Approx. 350 mm
  • Usage
  • OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
  • Test Range
  • 0 - 600 V & 0 - 5 A
  • Resolution
  • 0.1 V / 0.01 A
  • Automation Grade
  • Semi-Automatic
  • Interface Type
  • Banana/4 mm terminals
  • Features
  • Fitted with protective fuses, Heavy base, Easy wiring, Clear front panel layout
  • Operating Voltage
  • 230V AC, 50Hz
  • Measuring Range
  • 0 - 300 V (voltmeter), 0 - 10 A (ammeter)
  • Humidity
  • Up to 90% RH
  • Power Supply
  • 230V AC, 50Hz
  • Display Type
  • Analog / Digital (as per configuration)
  • Response Time
  • <2 seconds
  • Temperature
  • 10C to 50C
  • Application
  • To study OCC and Load Characteristics of DC Compound Generator
  • Number of Specimens
  • Single (One DC Generator at a time)
  • Product Type
  • OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR
  • Mounting Type
  • Table Top
  • Frequency
  • 50 Hz
  • Specimen Size
  • Standard Lab DC Compound Generator
  • Capacity
  • 1 kW
  • Machine Weight
  • Approx. 50 Kg
  • Test Speed
  • Variable up to 1500 RPM
  • Test Width
  • 300 mm
  • Test Stroke
  • 300 mm (Armature travel)
  • Control Mode
  • Manual/Automatic switchable
  • Calibration
  • Factory Calibrated and Certified
  • Equipment Type
  • Electrical Laboratory Trainer Equipment
  • Panel Material
  • Powder-coated MS Sheet
  • Field Winding
  • Shunt and Series field, Copper, Heavy gauge
  • Dimensions (LxWxH)
  • 600 mm x 300 mm x 350 mm
  • Connection Diagram
  • Silk screen printed on panel
  • Includes Load Bank
  • Resistive Type, 1 kW
  • Armature Type
  • Drum Type, Double Layer Winding
  • Safety Features
  • Shockproof panel, Overload and short-circuit protection
  • Standard Accessories
  • Connecting leads, Fuse, Test chart
  • Generator Type
  • Self and Separately Excited DC Compound
 

OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR

OCC and Load Charcteristics of DC Compound Generator

Suppliedwith DC Compound Motor 2 HP Coupled with DC Compound Generator 1 KW fitted with Proximity Sensor & Control Panelfitted with Necessary

Meters,Fixed Voltage DC Source , 4 Point DC Starter & Digital RPM Meter

Accessoriesfor above

ResistiveLamp Load 1 KW

OptionalAccessories

Variac 8Amps Single Phase



Comprehensive Generator Study Platform

Engineered for academic and research environments, this equipment supports in-depth learning of open-circuit (OCC) and load characteristics in DC compound generators. With options for both self and separately excited configurations, users can explore generator behavior with ease and clarity, thanks to a well-labeled, ergonomic interface and robust, high-quality materials.


Safe and User-Friendly Operation

Safety is paramount, with a shockproof panel, fitted fuses, and overload as well as short-circuit protection. The easy wiring system and clear front panel layout ensure safe and efficient setup, making it ideal for students, educators, and lab technicians conducting repetitive practical experiments.


High Accuracy and Versatility

This trainer is factory-calibrated for 1.5% accuracy and rapid response, supporting voltages up to 600 V and currents up to 5 A. It allows for both manual and automatic control modes and accommodates standard lab-sized DC compound generators, making it a versatile addition to any electrical laboratory.

FAQ's of OCC AND LOAD CHARCTERISTICS OF DC COMPOUND GENERATOR:


Q: How does the trainer help study OCC and load characteristics of a DC compound generator?

A: The trainer allows you to observe and record the open-circuit and load characteristics of a self or separately excited DC compound generator under controlled laboratory conditions. Complete with analog or digital metering, it enables detailed analysis by varying excitation, load, and speed.

Q: What safety features are included in this laboratory equipment?

A: The equipment is built with a shockproof powder-coated MS sheet panel and equipped with overload and short-circuit protection fuses. These features, along with easy wiring and a heavy base, ensure user safety during operation.

Q: When should this trainer be used during laboratory classes?

A: It is best utilized during practical sessions focused on electrical machines, generator performance analysis, and machine characteristics study. The trainer's setup supports both foundational and advanced experiments related to DC compound generators.

Q: Where can the equipment be used?

A: The OCC and Load Characteristics of DC Compound Generator Trainer is suitable for electrical laboratories in academic institutions, research centers, and technical training institutes.

Q: What is the process for conducting an experiment with this trainer?

A: Set up the DC compound generator with the provided connecting leads and safety fuses. Select the desired excitation mode, adjust load or excitation as required, and use the analog/digital displays to measure the generator's voltage and current characteristics. Data can be recorded for further analysis.

Q: Can the equipment be operated in humid environments?

A: Yes, it is designed to operate in ambient temperatures between 10C to 50C and humidity levels up to 90% RH, making it suitable for most laboratory conditions.

Q: What are the main benefits of using this trainer?

A: This trainer offers hands-on, accurate understanding of DC compound generator behavior. It ensures safe operation, provides high-precision measurements, supports flexible control modes, and is factory-calibrated and certified, making it ideal for reliable educational and research outcomes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

CURRENT INJECTOR 100A

CURRENT INJECTOR 100A

Minimum Order Quantity : 1 Piece

Product Type : CURRENT INJECTOR 100A

Application : CURRENT INJECTOR 100A

Usage : CURRENT INJECTOR 100A

Frequency : 50 Hz

Accuracy : 1%

DIELECTRIC ANTENNA

DIELECTRIC ANTENNA

Minimum Order Quantity : 1 Piece

Product Type : DIELECTRIC ANTENNA

Application : DIELECTRIC ANTENNA

Usage : Signal Transmission and Reception

Frequency : 2.4 GHz 2.5 GHz

Accuracy : High Precision

OPERATIONAL AMPLIFIER AS DIFFERENTIAL AMPLIFIER

OPERATIONAL AMPLIFIER AS DIFFERENTIAL AMPLIFIER

Minimum Order Quantity : 1 Piece

Product Type : OPERATIONAL AMPLIFIER AS DIFFERENTIAL AMPLIFIER

Application : electrical teaching

Usage : Industrial

Frequency : 50 Hertz (HZ)

Accuracy : 99.9 %

I.C. INJECTOR

I.C. INJECTOR

Minimum Order Quantity : 1 Piece

Product Type : I.C. INJECTOR

Application : ELECTRICAL TEACHING EQUIPMENT

Usage : ELECTRICAL TEACHING EQUIPMENT



Back to top