MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model) Specification

  • Display Type
  • Analog Meter
  • Mounting Type
  • Table Top
  • Application
  • MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model)
  • Automation Grade
  • Manual
  • Test Range
  • 0-750 watt per wattmeter
  • Measuring Range
  • 0-750 Watts (each wattmeter)
  • Operating Voltage
  • 230V AC
  • Equipment Type
  • MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model)
  • Response Time
  • Immediate (Analog Response)
  • Interface Type
  • Terminal panel connections
  • Features
  • Economical, educational model; robust construction; detachable loads; demonstration of balanced and unbalanced loads
  • Temperature
  • 0°C to 50°C
  • Usage
  • MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model)
  • Product Type
  • MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model)
  • Frequency
  • 50 Hz
  • Accuracy
  • Class 1.0 (wattmeter accuracy)
  • Humidity
  • Max. 85% RH (non-condensing)
  • Resolution
  • Analog pointer scale
  • Power Supply
  • 230V AC, 50Hz
  • Capacity
  • 2x 10A (wattmeter current rating)
  • Machine Weight
  • Approx. 6-8 kg
  • Control Mode
  • Manual
  • Panel Material
  • MS Powder Coated
  • Load Type
  • Resistive Load Bank Included
  • Input Type
  • Three-phase, star/delta connection facility
  • Wattmeter Specification
  • Dynamometer type, Analog Indicating Meter
  • Customization
  • Available as per academic requirement
  • Protection
  • Fuse protected for both supply and load circuits
  • Accessories Supplied
  • Connecting wires, Demo manual, User guide
  • Operating Environment
  • Indoor Laboratory Use
  • Connection Diagram
  • Silk-screened on panel for error-free wiring
 

MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model) Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model)

MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model) 

Measurement of Power in 3 Phase Circuit by Two Wattmeter Method

(Economical Model) Control Panel fitted with Necessary Meters

Accessories for above

Variac 2 Amps Three Phase

Loading Rheostat 1.5 KW Three Phase (Each Phase of 0.5 KW) in 4 Steps.



Accurate and Reliable Measurement

This economical model uses high-precision dynamometer-type analog wattmeters with Class 1.0 accuracy. Its immediate analog response and 0750 watt measuring range ensure accurate and consistent power readings in three-phase systems.


Educational and Demonstrative Utility

Perfect for academic labs, this equipment includes a clearly silk-screened wiring diagram and a detachable resistive load bank. Students can safely explore star and delta circuit connections and understand the principles behind balanced and unbalanced load measurements.


Robust and User-Friendly Design

Built from MS powder-coated panels, this device is robust, easy to maintain, and optimized for indoor environments. Fuse protection for supply and load circuits safeguards users and the equipment, while the table-top design adds convenience to laboratory setups.

FAQs of MEASUREMENT OF POWER IN 3 PHASE CIRCUIT BY TWO WATTMETER METHOD (Economical Model):


Q: How does the Two Wattmeter Method work in a three-phase circuit?

A: The Two Wattmeter Method measures the total power in a three-phase circuit by using two analog wattmeters. These wattmeters are connected to calculate the total power by summing their individual readings, which accommodates both balanced and unbalanced load conditions.

Q: What types of connections are supported by this equipment?

A: This economical model supports both star (Y) and delta () configurations, allowing users to study and measure power in various three-phase connection scenarios using the detachable resistive load bank.

Q: When should I use the Two Wattmeter Method for power measurement?

A: This method is ideal for educational labs and industrial settings where quick and reliable three-phase power measurements are required, especially for systems with both balanced and unbalanced loads.

Q: Where can I safely operate this power measurement setup?

A: The equipment is designed for indoor laboratory use, within an operating temperature range of 0C to 50C and humidity under 85% RH (non-condensing). Always place it on a stable table-top surface.

Q: What is the process for connecting and operating the equipment?

A: Refer to the silk-screened connection diagram on the panel for correct wiring. Attach the resistive loads and ensure all connections are secure. Switch on the power supply (230V AC, 50Hz), and then take wattmeter readings according to your experiment guidelines.

Q: Which safety features are incorporated in this model?

A: Fuse protection is provided for both supply and load circuits, reducing the risk of damage due to electrical faults. The robust MS powder-coated panel construction also enhances user safety and equipment durability.

Q: What are the main benefits of using this economical educational model?

A: This equipment offers hands-on learning with immediate analog response, enables versatile experiments with detachable loads, and enhances safety with fuse protection. Its clear diagrams and comprehensive accessories make it ideal for academic and training purposes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

PHOTO CELL CHARACTERISTICS APPARATUS

PHOTO CELL CHARACTERISTICS APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Photo Cell Characteristics Apparatus

Product Type : Photo Cell Characteristics Apparatus

Application : Photo Cell Characteristics Apparatus

Power Supply : 230V AC, 50Hz

Accuracy : 2%

RESISTIVE LAMP LOAD 1000W IN 5 STEPS WITHOUT LAMP

RESISTIVE LAMP LOAD 1000W IN 5 STEPS WITHOUT LAMP

Minimum Order Quantity : 1 Piece

Usage : Test load for lamps, electrical endurance testing

Product Type : RESISTIVE LAMP LOAD 1000W IN 5 STEPS WITHOUT LAMP

Application : RESISTIVE LAMP LOAD 1000W IN 5 STEPS WITHOUT LAMP

Power Supply : 230V AC, 50Hz, Single Phase

Accuracy : 2%

DATA FORMATTING AND CARRIER MODULATION TRANSMITTER

DATA FORMATTING AND CARRIER MODULATION TRANSMITTER

Minimum Order Quantity : 1 Piece

Usage : DATA FORMATTING AND CARRIER MODULATION TRANSMITTER

Product Type : DATA FORMATTING AND CARRIER MODULATION TRANSMITTER

Application : DATA FORMATTING AND CARRIER MODULATION TRANSMITTER

Power Supply : Electric

Accuracy : 99.9 %

STUDY OF COMPENSATION NETWORK

STUDY OF COMPENSATION NETWORK

Minimum Order Quantity : 1 Piece

Usage : STUDY OF COMPENSATION NETWORK

Product Type : STUDY OF COMPENSATION NETWORK

Application : STUDY OF COMPENSATION NETWORK



Back to top