trusted seller
Kjeldahl Distillation and Digestion Unit
Kjeldahl Distillation and Digestion Unit

Kjeldahl Distillation and Digestion Unit

MOQ : 1 , , Piece

Kjeldahl Distillation and Digestion Unit Specification

  • Frequency
  • 50 Hz
  • Measurement Range
  • 0.1 to 200 mg N
  • Model No
  • KJD-06
  • Usage
  • Heat And Refrigeration System
  • Temperature Range
  • Ambient to 450C
  • Power Source
  • Electric
  • Product Type
  • Kjeldahl Distillation and Digestion Unit
  • Accuracy
  • 2C
  • Capacity
  • 6 samples (approx. 300 ml per sample)
  • Core Components
  • Heater, Digestion Block, Distillation Assembly, Fume Hood
  • Voltage
  • 230V AC
  • Automation Grade
  • Semi-Automatic
  • Feature
  • Individual heater controls, acid resistant finishing, precise temperature control
  • Application
  • Heat And Refrigeration System
  • Equipment Materials
  • Stainless Steel body with Borosilicate glass tubes
  • Type
  • Kjeldahl Distillation and Digestion Unit
  • Display Type
  • Analog display
  • Dimension (L*W*H)
  • 670 x 400 x 500 mm
  • Weight
  • Approx. 30 kg
 

Kjeldahl Distillation and Digestion Unit Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Africa, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Kjeldahl Distillation and Digestion Unit



Experience peerless accuracy and premier functionality with the Kjeldahl Distillation & Digestion Unit, available at the lowest price for guaranteed value. Utilise offer access to sample capacities of 6, 12, or 20, all equipped with famed ceramic or nichrome wire heating elements. Featuring an inbuilt, chemical-resistant fume hood, separate control panel with indicator lamps and ON/OFF switches, and individual heater controls. The stainless steel body and borosilicate glass tubes ensure durability. Over-temperature and over-current protection offer supreme safety while precise temperature control ranges to 450C. Ideal for protein estimation in diverse analytical fields.

Applications and Versatility

The Kjeldahl Distillation and Digestion Unit is widely used for reliable protein estimation in food, feed, fertilizers, and chemical analysis. Its design is suitable for laboratories, research centres, and industrial facilities requiring robust analytical processing. Additionally, the equipment is valuable in academic settings, environmental analysis, and agricultural laboratories. The units adaptability and precision enable users to conduct thorough nitrogen determination and other chemical assays with confidence and efficiency.


Supply, Delivery, and Exchange Terms

Kjeldahl Distillation and Digestion Units are constantly delivered to leading markets across India and the globe, with a sale price structured for accessibility. Supply ability meets various batch sizes, and prompt exchange and delivery options ensure customers receive equipment quickly and reliably. Main export markets include laboratories, research institutes, and industrial clients. Flexible payment terms accommodate both bulk exchange and single purchases, enhancing overall satisfaction from manufacturers, distributors, and traders.


Kjeldahl Distillation & Digestion Unit Provided with two sets of mantle type heating platforms-one for Digestion and other for Distillation. Complete with condenser rack, lead fume duct and a pair of hangers, on a mild steel sheet tubular stand. Both units supplied with individual energy regulators. To work on 220 V AC 50 Hz single phase.

(i) 3 tests mantle type with 3 energy regulators.

(ii) 6 tests mantle type with 6 energy regulators.

Note : Glassware for above all at an Extra Cost.



FAQs of Kjeldahl Distillation and Digestion Unit:


Q: How is the Kjeldahl Distillation & Digestion Unit utilised for protein estimation?

A: This unit processes samples using the standard Kjeldahl method, enabling users to accurately estimate nitrogen and protein content in food, feed, fertilizer, and chemical samples.

Q: What safety features are included with this unit?

A: The unit provides over-temperature and over-current protection, along with individual heater controls and an acid-resistant finish, ensuring safe operation during extended laboratory use.

Q: When should laboratories choose the 6, 12, or 20 sample version?

A: Laboratories should select the version based on batch processing needs; higher sample capacity options are best for increased throughput and large-scale analyses.

Q: Where can the Kjeldahl Unit be installed?

A: Designed for bench-top installation, the unit fits efficiently into laboratory workspaces, facilitating ease of use and access to essential analytical tasks.

Q: What is the benefit of the inbuilt cooling and fume extraction system?

A: The integrated water circulation cooling system and chemical-resistant fume hood protect users from hazardous fumes and maintain the integrity of sample analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Heat And Refrigeration System Category

Vacuum Oven

Vacuum Oven

Minimum Order Quantity : 1 Piece

Usage : Heat And Refrigeration System

Product Type : Vacuum Oven

Voltage : 220 V

Power Source : Electric

Distillation Stills Manasty Type Wall Hanging

Distillation Stills Manasty Type Wall Hanging

Minimum Order Quantity : 1 Piece

Usage : Heat And Refrigeration System

Product Type : Distillation Stills Manasty Type Wall Hanging

Voltage : 220240 V

Power Source : Electric

Humidity Oven

Humidity Oven

Minimum Order Quantity : 1 Piece

Usage : Industrial

Product Type : Humidity Oven

Voltage : 220 Volt (v)

Power Source : Electric

Distillation Stills Barnstead Type

Distillation Stills Barnstead Type

Minimum Order Quantity : 1 Piece

Usage : Laboratory Equipment

Voltage : 220 Volt (v)

Power Source : Electric



Back to top