trusted seller
Flow Through Helical Coil
Flow Through Helical Coil

Flow Through Helical Coil

Price 99 INR/ Piece

MOQ : 1 Piece

Flow Through Helical Coil Specification

  • Operating Voltage
  • 230 V AC
  • Power Supply
  • 230 V, 50 Hz AC
  • Frequency
  • 50 Hz
  • Max Height
  • 45 cm
  • Resolution
  • 0.001 LPM
  • Number of Specimens
  • 1
  • Port Size
  • 1/2 inch BSP
  • Mounting Type
  • Bench-top
  • Display Type
  • Digital flow indicator
  • Automation Grade
  • Manual
  • Accuracy
  • 1.5%
  • Product Type
  • Flow Through Helical Coil
  • Hardness
  • Shore D 65
  • Specimen Size
  • 50 cm coil length
  • Test Range
  • 0.01 10 LPM (Liquid)
  • Response Time
  • <2 seconds
  • Temperature
  • Ambient (5C 40C)
  • Application
  • Momentum Transfer Lab Equipments
  • Humidity
  • 20% 80% RH
  • Measuring Range
  • 0.01 10 LPM
  • Features
  • Transparent helical coil, corrosion-resistant, easy sample loading and removal
  • Interface Type
  • Analog/Digital
  • Usage
  • Momentum Transfer Lab Equipments
  • Gas Pressure
  • 0.5 2 bar
  • Capacity
  • 1.5 L
  • Machine Weight
  • 65 kg
  • Test Speed
  • Variable, up to 1 m/s
  • Test Width
  • 120 mm
  • Test Stroke
  • 150 mm
  • Control Mode
  • Digital manual
 

Flow Through Helical Coil Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Letter of Credit (L/C), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Flow Through Helical Coil

Flow Through Helical Coil:

Micro Teknik delivering a wide gamut of Flow Through Helical Coil. This coil is designed by our adroit professionals using high-grade raw materials and modish technology, who have in-depth knowledge about the industrial standards. Available with us in numerous specifications, to meet the varied demands of our respectable clients.

Features:

  • Rust proof
  • Less maintenance
  • Maximum strength

Specifications:

  • Helical Coil Material Stainless Steel Dia 12
  • No. of Turns 15
  • Coil Tube Dia OD 21mm, ID 17mm (Approx.)
  • Sump Tank Material Stainless Steel/PVC, Capacity 50 Ltrs
  • Water Circulation FHP Pump, Crompton/Sharp make
  • Manometer 2 Nos
  • Flow measurement Rotameter
  • Piping GI and PVC
  • Control panel comprising of Standard make on off switch, Mains Indicator etc
  • The whole set-up is well designed and arranged in a good quality painted structure



Reliable and Accurate Flow Measurement

With a direct volumetric method and a graduated scale, the Flow Through Helical Coil enables precise measurement of liquid flow rates within a 0.01 10 LPM range. Accuracy is assured to within 1.5%, supported by a digital flow indicator and rapid response times. This ensures data integrity for experimental momentum transfer studies.


Safe and User-Friendly Operation

Engineered for safety and convenience, the device includes robust overload protection and a spill alarm for seamless laboratory use. Its plug-and-play installation with quick-connect fittings and flexible PVC piping allows for easy setup and sample changes, minimizing downtime and enhancing laboratory workflow.


Durable Construction for Long-Term Use

The helical coil apparatus boasts premium materials: transparent borosilicate glass and stainless steel. These provide superior resistance to corrosion and wear, while the polished finish simplifies cleaning. Designed for a service life exceeding ten years, it maintains reliable performance across varied temperatures and humidity levels.

FAQs of Flow Through Helical Coil:


Q: How is liquid flow measured in the Flow Through Helical Coil apparatus?

A: Liquid flow is measured directly using a graduated volumetric scale, complemented by a digital flow indicator, providing real-time readings with an accuracy of 1.5% and a resolution of 0.001 LPM.

Q: What are the installation requirements for this equipment?

A: The system features plug-and-play installation with quick-connect fittings and flexible PVC piping, allowing for easy bench-top mounting and immediate setup without specialized tools.

Q: When should the overload protection and spill alarm features be utilized?

A: These safety features activate automatically during excessive load or liquid spillage conditions, protecting both users and the equipment from accidents during operation in the laboratory.

Q: Where is the Flow Through Helical Coil typically used?

A: This apparatus is commonly utilized in academic and industrial labs across India conducting momentum transfer experiments, owing to its compliance with ISO 9001 lab standards and user-friendly design.

Q: What is the process for loading and removing samples?

A: Sample loading and removal are streamlined due to the coils transparent design and quick-connect fittings, allowing users to rapidly interchange specimens and maintain efficient lab operations.

Q: How does using borosilicate glass and stainless steel benefit users?

A: These materials ensure high resistance to corrosion, chemical exposure, and wear, enhancing safety and durability. The smooth polished finishes also facilitate easy cleaning and long-term reliability.

Q: What is the main advantage of the digital manual control mode?

A: Digital manual control offers precise regulation of test speed, flow, and measurement parameters, enabling tailored experimentation and accurate momentum transfer assessments within the test range.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Momentum Transfer Lab Equipments Category

Pressure Drop in Two Phase Flow

Pressure Drop in Two Phase Flow

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)

Automation Grade : Automatic

FIXED & FLUIDIZED BED APPARATUS

FIXED & FLUIDIZED BED APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)

Automation Grade : Automatic

PRESSURE DROP THROUGH PACKED BED APPARATUS

PRESSURE DROP THROUGH PACKED BED APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)

Automation Grade : Automatic

HYDRODYNAMICS OF PACKED BED APPARATUS

HYDRODYNAMICS OF PACKED BED APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Supply : Electric

Frequency : 50 Hertz (HZ)

Automation Grade : Automatic