trusted seller
Flash Point And Fire Point Apparatus
Flash Point And Fire Point Apparatus

Flash Point And Fire Point Apparatus

MOQ : 1 , , Piece

Flash Point And Fire Point Apparatus Specification

  • Automation Grade
  • Manual
  • Application
  • Pharmaceutical Lab Equipment
  • Frequency
  • 50 Hz
  • Product Type
  • Flash Point And Fire Point Apparatus
  • Accuracy
  • ±1°C
  • Model No
  • FP-CLV-01
  • Power Source
  • Electric (230V AC)
  • Feature
  • Corrosion-resistant, Removable parts for easy cleaning, Manual operation
  • Core Components
  • Test cup, Heating plate, Thermometer, Flame exposure device
  • Measurement Range
  • 50°C to 360°C
  • Usage
  • Pharmaceutical Lab Equipment
  • Voltage
  • 230 V
  • Capacity
  • 500 ml test cup
  • Temperature Range
  • Up to 360°C
  • Equipment Materials
  • Brass cup, Stainless Steel frame, Bakelite handle, Powder coated body
  • Type
  • Open Cup (Cleveland) and Closed Cup (Pensky Martens)
  • Display Type
  • Analog (dial thermometer)
  • Dimension (L*W*H)
  • Approx. 320 x 240 x 410 mm
  • Weight
  • Approx. 8-10 kg
  • Thermometer Range
  • 0C to 360C standard glass thermometer
  • Safety Feature
  • Heat-resistant handle, Built-in fuse protection
  • Test Method Supported
  • Open Cup (Cleveland), Closed Cup (Pensky Martens)
  • Heating Control
  • Variable heating regulator
  • Ignition System
  • Manual flame application with gas jet
 

Flash Point And Fire Point Apparatus Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Flash Point And Fire Point Apparatus

Flash Point And Fire Point Apparatus

ELECTRIC FLASH AND FIRE POINT APPARATUS

Electric Flash Fire Point Tester ( Cleveland Open-Cup )

Application:

Its used to determine flash and fire point of bitumen

Specifications:

Power voltage: 220V10%

Can adjust the rise temperature speed

Feature:

Total stainless steel worktable, with flame lighter



Versatile Testing Methods

This apparatus supports both Open Cup (Cleveland) and Closed Cup (Pensky Martens) test methods, ideal for a wide variety of pharmaceutical laboratory analyses. The interchangeable system allows users to perform multiple types of flash and fire point determination with a single device, improving efficiency in lab operations.


User-Focused Safety Features

Safety is prioritized through a heat-resistant Bakelite handle and built-in fuse protection that prevents electrical hazards. The stainless steel frame and powder-coated body are corrosion-resistant, promoting longevity even with daily use. The design reduces risk during manual flame application and cleaning.


Precision Heating and Measurement

The variable heating regulator and high-accuracy (1C) standard glass thermometer enable controlled, precise temperature adjustments. The large analog dial display ensures clear monitoring during the entire heating process, making it reliable for critical pharmaceutical quality control.

FAQs of Flash Point And Fire Point Apparatus:


Q: How do you operate the manual ignition system on this Flash Point Apparatus?

A: The manual ignition system utilizes a gas jet for flame application. To operate, attach the gas supply as per the apparatus guidelines, ignite the flame, and carefully introduce it to the sample cup using the provided flame exposure device while adhering to lab safety protocols.

Q: What procedures are supported by this apparatus for flash and fire point testing?

A: The device supports both Open Cup (Cleveland) and Closed Cup (Pensky Martens) methodologies, allowing for standard determination of flash and fire points as required in pharmaceutical quality control and research labs.

Q: When should the apparatus be cleaned, and how can it be safely maintained?

A: It is recommended to clean the apparatus after each test to prevent residue build-up. The removable brass cup and other core components can be detached for thorough cleaning. Always allow the equipment to cool before disassembly to ensure safety.

Q: Where is this apparatus commonly used?

A: This model is widely used in pharmaceutical laboratories across India, especially by distributors, exporters, manufacturers, suppliers, and traders needing reliable and standardized flash point determination.

Q: What are the core benefits of using this equipment in pharmaceutical labs?

A: Key benefits include accurate, repeatable results, manual control for flexible operation, safe handling through heat-resistant materials, and easy-to-clean removable parts, all vital for rigorous pharmaceutical testing environments.

Q: How does the heating control and measurement range optimize the testing process?

A: The variable heating regulator allows users to precisely adjust the temperature up to 360C, while the analog thermometer (range 0360C, accuracy 1C) ensures reliable measurements, making it suitable for a variety of substances.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Lab Equipment Category

Bottle Washing Machine

Bottle Washing Machine

Minimum Order Quantity : 1 Piece

Usage : Pharmaceutical Lab Equipment

Power Source : Electric

Voltage : 220 V

Product Type : Bottle Washing Machine

Frequency : 50 Hz

Vertical Slab Gel Electrophoresis Apparatus

Vertical Slab Gel Electrophoresis Apparatus

Minimum Order Quantity : 1 , , Piece

Usage : Pharmaceutical Lab Equipment

Power Source : AC Mains

Voltage : 220V 10%

Product Type : Vertical Slab Gel Electrophoresis Apparatus

Frequency : 50/60 Hz

Tablet Hardness Tester

Tablet Hardness Tester

Minimum Order Quantity : 1 Piece

Usage : Pharmaceutical Lab Equipment

Power Source : Manual (Hand Operated)

Product Type : Tablet Hardness Tester

Plythesmography   .

Plythesmography .

Minimum Order Quantity : 1 Piece

Usage : Pharmaceutical Lab

Power Source : Electric

Voltage : 220 Volt (v)

Product Type : Plythesmography

Frequency : 50 Hertz (HZ)



Back to top