trusted seller
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA

EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA

MOQ : 1 Piece

EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA Specification

  • Resolution
  • 1 dB (gain), 1 (rotation)
  • Operating Voltage
  • 230V AC
  • Automation Grade
  • Semi-automatic (manual and automatic options)
  • Temperature
  • 0C to 50C operating
  • Port Size
  • Standard BNC/SMA connectors
  • Equipment Type
  • EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
  • Test Range
  • typically 20 MHz - 3 GHz (depends on signal generator/receiver)
  • Accuracy
  • Better than 2 dB (gain measurement), 2 (angle resolution)
  • Power Supply
  • 230V AC, 50Hz
  • Application
  • EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
  • Specimen Size
  • Supports antennas up to 40 cm length
  • Usage
  • EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
  • Measuring Range
  • Dependent on selected signal generator/receiver (20 MHz - 3 GHz typical)
  • Display Type
  • Analog/digital meter or PC-based graph via software
  • Response Time
  • Instantaneous (electronic capture)
  • Number of Specimens
  • 1 antenna per experiment
  • Humidity
  • Up to 85% RH (non-condensing)
  • Product Type
  • EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA
  • Frequency
  • 20 MHz - 3 GHz
  • Features
  • Motorized rotation, precise angle marking, PC connectivity, modular setup
  • Mounting Type
  • Tabletop with adjustable antenna holder
  • Max Height
  • Antenna fixture: up to 50 cm
  • Interface Type
  • BNC/SMA signal and control
  • Capacity
  • Single unit; supports one measurement at a time
  • Machine Weight
  • Approx. 15 kg
  • Test Speed
  • Variable (1-10 RPM rotation for antenna fixture)
  • Test Width
  • N/A (dependent on antenna under test)
  • Test Stroke
  • N/A (not applicable to antenna systems)
  • Control Mode
  • Manual/Automatic via panel controls
  • Measurement Method
  • Comparative with reference and test antennas
  • Software Support
  • PC interface via USB for pattern plotting and gain reporting
  • Rotation Range
  • 0 to 360 continuous
  • Receiver Sensitivity
  • -90 dBm or better
  • Data Output
  • Live polar plot (digital/PC software)
  • Included Accessories
  • Reference antenna, signal generator, calibration kit, cables
  • Dimensions
  • Approx. 600 mm x 350 mm x 350 mm
  • Antenna Types Supported
  • Dipole, Yagi, Patch, and Monopole (standard attachments included)
  • Calibration Capability
  • External/automatic calibration routines provided
  • Signal Generator Output Power
  • Up to +13 dBm
  • Construction Material
  • Powder coated steel frame with non-conductive base
 

EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA

Experiments to measure the Polar Pattern & gain characteristics of theantenna

To MeasureThe Polar Pattern Of The Antenna: Micro Teknk is manufacture, exporters &suppliers Experiments: To measure the polar pattern & gain of the antennas(Pyramidal horn. Pick up horn, slotted horn, Dielectric horn, sectorial horn& parabolic disc).



Versatile Antenna Testing Platform

This equipment accommodates a broad spectrum of antenna types-including dipole, Yagi, patch, and monopole designs-thanks to its standard attachments and modular configuration. Its adjustable fixture securely holds antennas up to 40 cm in length and 50 cm in height, making it ideal for laboratory and training environments requiring rigorous and repeatable measurement experiments.


Comprehensive Measurement Capabilities

Ensure accuracy in antenna characterization with a system that provides both comparative gain measurements and polar pattern plotting. Motorized rotation enables continuous 0 to 360 scans, while software support allows live data visualization via PC. Calibration routines (external/automatic) maintain reliable gain and angle measurements, offering a gain measurement accuracy of better than 2 dB and 1 angular resolution.


User-Friendly Operation and Data Analysis

Control panel options permit both manual and automatic operation, accommodating various experiment protocols and speeds (1-10 RPM). Data is instantly captured and displayed as analog/digital readouts or comprehensive software-driven polar plots, making detailed analysis and report generation straightforward for students or professionals.

FAQ's of EXPERIMENTS TO MEASURE THE POLAR PATTERN & GAIN CHARACTERISTICS OF THE ANTENNA:


Q: How do I set up the system for measuring antenna polar patterns?

A: Begin by securely mounting the desired antenna onto the adjustable fixture using the standard attachments for dipole, Yagi, patch, or monopole antennas. Connect the reference antenna, signal generator, and calibration kit as instructed. Ensure all connections use BNC/SMA cables, then use the control panel or PC software to initiate rotation and data-capture functions.

Q: What is the typical process for conducting antenna gain and pattern measurements?

A: The system employs a comparative measurement method: a reference antenna and a test antenna are alternately measured under the same conditions. The motorized fixture rotates the test antenna 0-360, capturing signal strength at various angles, which is then compared to the reference. Software automatically plots the polar pattern and calculates gain data.

Q: When should calibration routines be performed, and how are they executed?

A: Calibration must be performed before initial measurement or when changing antennas or frequency bands. Use the included calibration kit and activate the calibration procedure via the control panel or PC software, which guides users through external or fully automatic routines to ensure measurement accuracy.

Q: Where can the data output from experiments be accessed or analyzed?

A: Measurement results, including live polar plots and gain calculations, are accessible in real time through the PC software connected via USB. Data can be exported or printed for analysis and report preparation, supporting laboratory records or research publication.

Q: What benefits do motorized rotation and PC connectivity provide during experiments?

A: Motorized rotation allows smooth, precise angle sweeps from 0 to 360, ensuring high measurement resolution and reproducibility. PC connectivity enables live data monitoring, advanced plotting, and detailed gain reporting, enhancing both instruction and research efficiency.

Q: How is the system powered and what are the environmental operating limits?

A: The system operates on standard 230V AC, 50Hz power, with all signal connections via BNC or SMA interfaces. It is designed for a laboratory environment, functioning reliably between 0C and 50C, and can handle up to 85% RH (non-condensing) humidity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Teaching Equipment Category

CROSS DIRECTIONAL COUPLER

CROSS DIRECTIONAL COUPLER

Minimum Order Quantity : 1 Piece

Usage : CROSS DIRECTIONAL COUPLER

Application : CROSS DIRECTIONAL COUPLER

Frequency : 50 Hz

POWER IN 1 PHASE CIRCUIT USING 1 PHASE WATTMETERS, CT & PT

POWER IN 1 PHASE CIRCUIT USING 1 PHASE WATTMETERS, CT & PT

Minimum Order Quantity : 1 Piece

Usage : Laboratory education, demonstration, training

Application : POWER IN 1 PHASE CIRCUIT USING 1 PHASE WATTMETERS, CT & PT

Product Type : POWER IN 1 PHASE CIRCUIT USING 1 PHASE WATTMETERS, CT & PT

Frequency : 50 Hz

SUPERPOSITION THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

SUPERPOSITION THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

Price 1100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : electrical teaching

Application : electrical teaching

Product Type : SUPERPOSITION THEOREM WITH ALUMINUM PANEL & DIGITAL PANEL METERS

Frequency : 50 Hertz (HZ)

VARIAC 2 AMPS THREE PHASE

VARIAC 2 AMPS THREE PHASE

Price 500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Laboratory

Application : electrical teaching

Product Type : VARIAC 2 AMPS THREE PHASE

Frequency : 50 Hertz (HZ)



Back to top