trusted seller
Digital UV-Visible Spectrophotometer
Digital UV-Visible Spectrophotometer

Digital UV-Visible Spectrophotometer

MOQ : 1 Piece

Digital UV-Visible Spectrophotometer Specification

  • Usage
  • Analytical Lab Instrument
  • Capacity
  • 1 cuvette slot (single sample measurement)
  • Application
  • Analytical Lab Instrument
  • Feature
  • Digital operation, high sensitivity, fast response
  • Frequency
  • 50/60 Hz
  • Temperature Range
  • Ambient
  • Product Type
  • Microprocessor Uv-vis Spectrophotometer
  • Voltage
  • 220 V
  • Accuracy
  • 0.5% T
  • Model No
  • UV-1900
  • Power Source
  • 220V AC
  • Automation Grade
  • Automatic
  • Measurement Range
  • 1901100 nm
  • Core Components
  • Monochromator, Deuterium Lamp, Halogen Lamp
  • Equipment Materials
  • Robust ABS body
  • Type
  • Microprocessor UV-Vis Spectrophotometer
  • Display Type
  • Large digital LCD display
  • Dimension (L*W*H)
  • 500 x 350 x 220 mm
  • Weight
  • Approx. 12 kg
  • Stray Light
  • <0.5%T at 220 nm & 340 nm
  • Operating Modes
  • Transmittance, Absorbance, Concentration, Factor
  • Data Output Interface
  • RS232/USB
  • Lamp Source
  • Deuterium (UV) and Tungsten (Visible)
  • Calibration
  • Automatic wavelength and absorbance calibration
  • Photometric Range
  • 0-200 %T, -0.3-3.0A
  • Spectral Bandwidth
  • 2 nm
  • Resolution
  • 0.1 nm
  • Wavelength Setting
  • Auto and manual
  • Sample Holder Type
  • Standard 10 mm cuvette holder
 

Digital UV-Visible Spectrophotometer Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Digital UV-Visible Spectrophotometer

Microprocessor Uv-vis Spectrophotometer (Cat No. - EM-142N)

MICROPROCESSOR UV SPECTRO PHOTOMETER :


SPECTREAL

  • Range                        195 to 1000 nm
  • Resolution                  0.1 nm
  • Sepctral Band Width   2nm
  • Accuracy                   0.5 nm
  • Repeatability              0.3 nm

PHOTOMETRIC
  • Photometric Range   % T : 0 to 100 % , Abs : 0 to 1.999 Conc.: 0 to 1999, K-Factor : 0 to 1999
  • Accuracy                 0.005 Abx at 1.0 Abs  
  • Stray Light              Less than 0.1 % at 320 nm
  • Data Readout          Single Line LCD display  
  • Key Board               4 Keys, soft touch memberance type
  • Serial Interface       RS 232C interface
  • Light Source            a)  Tungsten Halogen Lamp  b)  Deuterium Lamp (D2)
  • Detector                  Wide range Silicon Photodiode
  • Readability              1 Count
  • Printer Interface      Printer interface for any centronics dot matrix printer
  • Optics                    Complete mirror optics with resolution 1200 grooves/mm grating
  • Power                     230V 10% AC, 50 Hz


Precise Spectral Measurement for Analytical Labs

Engineered for high sensitivity and fast response, the UV-1900 spectrophotometer enables accurate measurement of transmittance, absorbance, and concentration in a wide wavelength range. The monochromator and robust optical components ensure excellent resolution and low stray light, critical for complex sample analysis in various fields.


User-Friendly Operation and Automation

With both auto and manual wavelength setting options, automatic calibration, and digital LCD display, this spectrophotometer caters to routine as well as advanced laboratory needs. The intuitive interface and handy data output options via RS232/USB simplify workflow, supporting efficient data management in research and industrial settings.


Reliable Design and Durable Components

Built from high-quality ABS body material and incorporating Deuterium and Tungsten lamps, the device is durable yet compact. Designed to operate at ambient temperatures, it is suitable for everyday laboratory use and can be easily accommodated thanks to its manageable size and single cuvette slot.

FAQs of Digital UV-Visible Spectrophotometer:


Q: How does the UV-1900 spectrophotometer perform wavelength calibration?

A: The instrument features automatic wavelength and absorbance calibration, ensuring high accuracy and repeatability. This process can be executed with a simple command from the menu, minimizing manual intervention and enhancing measurement reliability.

Q: What is the measurement process for samples with this spectrophotometer?

A: To measure a sample, place the standard 10 mm cuvette containing your sample into the holder. Select the desired operating mode (transmittance, absorbance, concentration, or factor) and input the relevant parameters. The instrument then scans the sample across the chosen wavelength range and displays the results on the digital LCD screen.

Q: When should I use the automatic vs. manual wavelength setting?

A: Automatic wavelength selection is recommended for routine samples and high-throughput operations to save time and reduce human error. Manual settings can be used for method development, custom applications, or when precise control over analysis conditions is required.

Q: Where can the UV-1900 spectrophotometer be effectively utilized?

A: This instrument is ideal for analytical laboratories in pharmaceutical, environmental, chemical, food, and research institutions across industries. It is suitable for both teaching labs and professional analytical testing facilities.

Q: What benefits do Deuterium and Tungsten lamps provide in this device?

A: The Deuterium lamp ensures stable UV light for measurements in the 190320 nm range, while the Tungsten lamp covers the visible spectrum. This broadens the measurement capacity and ensures precise data across the full 1901100 nm wavelength range.

Q: How can I export measurement data from the UV-1900 spectrophotometer?

A: Measurement results can be easily exported via the RS232 or USB data output interfaces, allowing seamless transfer to laboratory information systems or PCs for further analysis and documentation.

Q: What makes this spectrophotometer beneficial for analytical labs?

A: The combination of digital operation, high sensitivity, automatic calibration, versatile measurement modes, and robust design makes the UV-1900 particularly beneficial for laboratories demanding precision, reliability, and operational efficiency in their spectrophotometric analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Analytical Lab Instrument Category

Digital Salinity Meter

Digital Salinity Meter

Minimum Order Quantity : 1 Piece

Power Source : Battery Operated (2 x 1.5V AAA)

Usage : Analytical Lab Instrument

Equipment Materials : ABS Plastic Body

Core Components : Sensor, Microcontroller, LCD Display

Measurement Range : 0100 ppt

Field Turbidity Meter

Field Turbidity Meter

Minimum Order Quantity : 1 Piece

Power Source : Battery Operated

Usage : Analytical Lab Instrument

Equipment Materials : ABS Plastic Body

Core Components : Sensing Probe, Digital Display Module

Measurement Range : 01000 NTU

Microprocessor Ph / Temp / Mv Meter

Microprocessor Ph / Temp / Mv Meter

Minimum Order Quantity : 1 Piece

Power Source : 230V AC mains

Usage : Analytical Lab Instrument

Equipment Materials : ABS plastic housing

Core Components : Microprocessor, electrode sensor

Measurement Range : pH: 0.00 to 14.00; Temp: 0C to 100C; mV: 1999

Field Digital Ph Meter

Field Digital Ph Meter

Minimum Order Quantity : 1 Piece

Power Source : AAA Batteries

Usage : Analytical Lab Instrument

Equipment Materials : ABS Plastic Body

Core Components : Electrode, LCD Display, Microprocessor

Measurement Range : 0.00 14.00 pH



Back to top