Cleavland Flash and Fire Point Specification

  • Features
  • Brass Test Cup, Flame Device, Thermometer Support, Heavy Duty Construction
  • Frequency
  • 50 Hz
  • Display Type
  • Analog / Glass Thermometer
  • Power Supply
  • 230 V AC, 50 Hz
  • Mounting Type
  • Bench Top
  • Gas Pressure
  • Atmospheric
  • Automation Grade
  • Manual
  • Application
  • Petroleum Testing Instruments
  • Max Height
  • 350 mm
  • Operating Voltage
  • 230V AC
  • Humidity
  • Standard Laboratory Conditions
  • Equipment Type
  • Petroleum Testing Apparatus
  • Usage
  • Petroleum Testing Instruments
  • Number of Specimens
  • Single Specimen
  • Test Range
  • Up to 400°C
  • Product Type
  • Cleavland Flash and Fire Point
  • Resolution
  • 1°C
  • Interface Type
  • Manual
  • Measuring Range
  • Ambient to 400°C
  • Accuracy
  • ±1°C
  • Response Time
  • Instantaneous on ignition
  • Specimen Size
  • Standard Cleveland Cup
  • Temperature
  • Ambient to 400°C
  • Capacity
  • 150 ml (Test Cup)
  • Machine Weight
  • 15 kg (Approx)
  • Test Speed
  • Standard as per IS: 1448 (P-69)
  • Control Mode
  • Manual
  • Ignition Source
  • Gas Test Flame (with manual control)
  • Heating Source
  • Electric Heater
  • Thermometer Range
  • -6C to 400C (as per requirement)
  • Conformance Standards
  • IS: 1448 (P-69), ASTM D92
  • Safety Features
  • Thermal Insulation, Flame Shield
  • Cup Type
  • Open Cup (Cleveland)
  • Included Accessories
  • Test Cup, Heater, Flame Device, Thermometer Holder, User Manual
  • Material of Construction
  • Mild Steel Body with Powder Coating
 

Cleavland Flash and Fire Point Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Middle East, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Cleavland Flash and Fire Point

Cleavland Flash & Fire Point:

Our clients can avail from us a wide array of Open Flash Point & Fire Points at market leading prices. These products are suitable for determining the flash and fire point of petroleum products except when the cleveland apparatus is specified. Moreover, our range is used for variegated scientific applications, 



Precision Testing for Petroleum Laboratories

Designed for accuracy and safety, this apparatus provides dependable measurement of flash and fire points in petroleum samples. The robust construction, along with built-in insulation and flame shields, ensures both operator protection and reliability during high-temperature testing. Its compatibility with standard laboratory conditions and a wide operational temperature range make it an essential instrument for quality assurance and R&D settings.


Manual Control and User-Friendly Design

The equipment operates through straightforward manual control, offering clear analog temperature readings and immediate response upon ignition detection. Accessories like the brass test cup, thermometer holder, and flame device simplify setup and operation. Its bench-top mounting fits seamlessly into space-constrained labs while optimizing ease-of-use and maintenance.

FAQs of Cleavland Flash and Fire Point:


Q: How is the Cleveland Flash and Fire Point Apparatus operated?

A: This apparatus is manually operated, with an electric heater and a gas test flame (manual control) used to heat the petroleum sample. The temperature is observed through an analog or glass thermometer, and the response is instantaneous upon ignition detection.

Q: What are the main benefits of using this instrument in petroleum testing?

A: The main advantages include high accuracy (1C), robust safety features such as thermal insulation and flame shields, and compliance with IS: 1448 (P-69) and ASTM D92 standards. It allows for precise determination of a samples flash and fire points, critical for safety and quality control in petroleum products.

Q: When should the Cleveland apparatus be used during petroleum quality testing?

A: It is essential during routine safety and performance evaluations of petroleum products to assess their volatility and risk of ignition, typically required at various stages of processing, shipment, and quality certification.

Q: Where can this apparatus be installed for optimal use?

A: The bench-top design is ideal for standard laboratories equipped with 230 V AC, 50 Hz power supplies and atmospheric gas pressure. It must be used in controlled environments to ensure measurement precision and user safety.

Q: What is the process followed during a flash and fire point test?

A: The process involves filling the standard Cleveland test cup (150 ml capacity) with the petroleum sample, heating it at a controlled rate, and periodically applying the test flame manually. The temperature at which vapor ignites denotes the flash point, and sustained burning indicates the fire point.

Q: How does the apparatus ensure operator safety during high-temperature testing?

A: Thermal insulation, a flame shield, and robust powder-coated construction safeguard users from heat exposure and accidental flame contact throughout the testing procedure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Instruments Category

Hydrocarbon Fractionation Unit

Hydrocarbon Fractionation Unit

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Power Supply : 220V/380V, 50/60Hz

Measuring Range : C5C20 hydrocarbons

Accuracy : 0.5C

Resolution : 0.1C

European Diesel Injector

European Diesel Injector

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Power Supply : 12V DC

Measuring Range : 02000 bar

Accuracy : 1.5%

Resolution : 1 bar

Oxidation Stability Test Apparatus

Oxidation Stability Test Apparatus

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Power Supply : 230V AC, 50 Hz

Measuring Range : 0999 minutes

Accuracy : 1 minute

Resolution : 1 minute

Tar Viscometer

Tar Viscometer

Minimum Order Quantity : 1 Piece

Usage : Petroleum Testing Instruments

Power Supply : 230 V AC, 50 Hz

Measuring Range : Seconds to efflux 50 cc

Accuracy : 1 sec

Resolution : 1 sec



Back to top