trusted seller
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen
Burner, Bunsen

Burner, Bunsen

Price 10 INR/ Piece

MOQ : 1 , , Piece

Burner, Bunsen Specification

  • Properties
  • Corrosion resistant, sturdy base, adjustable air supply
  • Use
  • Blood Bank Instruments
  • Product Type
  • Burner, Bunsen
  • Phase
  • Single Phase
  • Automation Grade
  • Manual
  • Power
  • Not applicable (manual gas supply)
  • Dimension (L*W*H)
  • Base diameter 75 mm, Height 150 mm
  • Treatment Type
  • Heat/Flame treatment
  • Application
  • Blood Bank Instruments
  • Suitable For
  • Laboratory use, educational and research laboratories
  • Shape
  • Cylindrical stem with round base
  • Weight
  • Approx. 250 g
  • Temperature Range
  • Up to 1200C flame temperature
  • Function
  • Produces controlled flame for heating/sterilization
  • Material
  • Chrome-plated brass and cast iron base
  • Color Code
  • Silver/Blue-Gray
  • Height
  • 150 mm (approx.)
  • Power Source
  • LPG/Compressed Gas
 

Burner, Bunsen Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Burner, Bunsen

Burner, Bunsen

CODE: MCML-51B

Functional description:

A small adjustable gas burner used in laboratories as a source of heat.

Technical:

Bunsen burner with:

  • Base is powder coated
  • Brass pipe chrome plated
  • Adjustable gas nozzle
  • For use with propane or butane gas
  • Screw valve
  • Flames stabilizer
  • Brass spouts 11 x 130 (h) mm
  • Safety valve to stop the passage of gas in the event of flame extinction
  • Accessories: 5 m Gas tubing.




Adjustable Air Supply for Flame Control

The Bunsen burners adjustable collar regulates the amount of air mixed with the fuel, enabling users to switch between luminous and non-luminous flames. This feature provides flexibility for different laboratory procedures, ensuring optimum heating or sterilization efficiency during operations.


Durable Construction for Enhanced Stability

Manufactured with chrome-plated brass and a heavy cast iron base, the burner offers superior corrosion resistance and stability. The wide and sturdy foundation minimizes tipping risks, enhancing safety during intensive laboratory use.


Safe and Efficient for Laboratory Applications

With a heat-resistant body and a secure barbed gas nozzle, this burner is designed for safe, consistent operation. Ideal for blood bank instruments, and suitable for a range of educational and research laboratories, it supports precise flame control for various heat treatment procedures.

FAQs of Burner, Bunsen:


Q: How do you adjust the flame on this Bunsen burner?

A: To adjust the flame, simply rotate the collar located near the burners base to control the air supply. Increasing air results in a non-luminous, hotter flame, while restricting air makes the flame more luminous and cooler.

Q: What types of gases are compatible with this burner?

A: This burner operates efficiently with LPG, coal gas, or natural gas provided through the barbed gas inlet nozzle, ensuring secure attachment and safe use in laboratory settings.

Q: When is it recommended to use a luminous versus a non-luminous flame?

A: A luminous flame is preferable when gentle heating is required, while a non-luminous (blue) flame is best for rapid and efficient heat transfer, such as sterilization or boiling in laboratory processes.

Q: Where can this Bunsen burner be utilized?

A: This burner is suitable for blood banks, research institutions, educational laboratories, and other scientific environments requiring controlled flame for heating or sterilization tasks.

Q: What is the process for safely connecting the gas supply?

A: Attach the gas tube securely to the barbed nozzle at the burners inlet. Ensure the connection is firm and leak-free before igniting the burner using an external source like a match or spark lighter.

Q: How does the burner benefit laboratory procedures?

A: Its adjustable air supply enables precise flame control, supporting sensitive heating applications, sterilization, and scientific experiments. The corrosion-resistant, stable design further ensures safe, long-term use in laboratory environments.

Q: What safety features does this Bunsen burner include?

A: It incorporates a heavy, wide cast iron base for stability, a heat-resistant body, and a secure barbed fitting to minimize the risk of tipping, burns, or gas leaks during operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Blood Bank Instruments Category

Platelet Agitator With Incubator

Platelet Agitator With Incubator

Minimum Order Quantity : 1 Piece

Power Source : Electric

Material : Powder Coated Steel Body

Application : Blood Bank Instruments

Cooling Compartment

Cooling Compartment

Minimum Order Quantity : 1 Piece

Power Source : Manual

Material : Stainless steel

Application : Blood Bank Instruments

Color : Silver

Condition : New

Blood Bag Sealer

Blood Bag Sealer

Minimum Order Quantity : 1 Piece

Power Source : Electric

Material : Mild Steel

Application : Hospital

Color : White Blue

Condition : New

Blood collection monitor

Blood collection monitor

Minimum Order Quantity : 1 Piece

Power Source : Electric

Material : Mild Steel

Application : Hospital

Color : White

Condition : New



Back to top