Biological Safety Cabinet Class II Type B2 Specification

  • Color
  • White/Blue (custom) or as per order
  • Hole Size
  • Standard (customizable)
  • Material
  • Stainless Steel 304/316
  • Installation Type
  • Floor Mounted
  • Pressure Range
  • 50-100 Pa
  • Control System
  • Digital
  • Features
  • UV Light, Easy-to-clean interior, Audible & visual alarms, Pressure & airflow monitoring, LED lighting, Interlock system
  • Vaccum Range
  • Up to 200 mm WG
  • Humidity %
  • 30-70%
  • Filtration Property
  • HEPA filtration, 100% exhaust, zero recirculation
  • Efficiency (%)
  • 99.999%
  • Noise Level
  • <65 dB (A)
  • Filters
  • HEPA Filter (H14 standard), Pre-filter
  • Ventilation
  • External Duct Required
  • Maintenance Type
  • Low, easy access panels
  • Energy Consumption
  • Low Power Consumption
  • Flow Rate
  • 320-700 m3/h
  • Dust
  • HEPA Filter retains particles 0.3 micron
  • Frequency
  • 50/60 Hz
  • Dust %
  • <0.001%
  • Output
  • Direct Exhaust, 100% Air Exhausted
  • Application
  • CLEAN AIR SYSTEM
  • Automatic Grade
  • Automatic
  • Capacity
  • 4 feet (custom sizes available)
  • Power
  • 0.75 kW
  • Voltage
  • 220V-240V AC
  • Dimension (L*W*H)
  • 1300 x 800 x 2200 mm
  • Weight
  • Approx 180 kg
  • Warranty
  • 1 YEAR
  • Exhaust System
  • 350 mm diameter (standard), ducting connection included
  • Inflow and Downflow Velocity
  • 0.55 m/s (inflow), 0.33 m/s (downflow)
  • Display
  • Digital display for airflow and filter life indication
  • Equipment Type
  • Class II Type B2 Biological Safety Cabinet
  • Air Cleanliness
  • ISO Class 5 (Class 100)
  • Caster Wheels
  • Heavy-duty, lockable
  • Work Area Illumination
  • >1000 lux
  • Side Wall Construction
  • Single piece, seamless, stainless steel
  • Gloves Port
  • Not applicable (open-front design)
  • Lighting
  • LED illumination, UV germicidal lamp
  • Front Opening Height
  • 200-250 mm
  • Sash Type
  • Sliding vertical toughened glass, counterbalanced
  • Safety Alarms
  • Filter clogging, low airflow, sash position
  • Work Surface
  • Dished/Removable stainless steel
 

Biological Safety Cabinet Class II Type B2 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Packaging Details
  • Carton Box, Export Quality also Available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001, CE
 

About Biological Safety Cabinet Class II Type B2

JCA-021 Teknik Biological Safety Cabinet Class II Type B2 is designed with inward air flow velocity (0.55m/s) for personnel protection, HEPA- filtered laminar airflow for product protection and HEPA-filtered exhausted air for environmental protection.

It is suitable for microbiological research in the absence of volatile or toxic chemicals and radionuclide, since air is recirculated within the work area



Comprehensive Containment and Filtration

This Class II Type B2 cabinet ensures complete safety by exhausting all contaminated air through a direct ducted system with HEPA filtration, meeting rigorous ISO Class 5 standards. The zero recirculation design guarantees minimal cross-contamination risk for personnel, samples, and the environment, making it essential for sensitive biological applications.


User-Friendly Features for Reliable Operation

With its intuitive digital control system, real-time filter life monitoring, and audible/visual safety alarms, this cabinet streamlines daily laboratory operations. The counterbalanced sliding vertical sash, easy-access panels, and removable work surface ensure ergonomic convenience while simplifying cleaning and maintenance tasks.

FAQ's of Biological Safety Cabinet Class II Type B2:


Q: How does the Class II Type B2 Biological Safety Cabinet ensure maximum safety during laboratory use?

A: This cabinet incorporates zero air recirculation with 100% HEPA-filtered exhaust, a seamless stainless steel work chamber, and alarms for low airflow, filter clogging, and incorrect sash position. These features, combined with external ducting and an interlock system, maximize containment and user safety.

Q: What are the primary benefits of using the sliding vertical sash design?

A: The counterbalanced, toughened glass sliding vertical sash enhances user safety by providing a protective barrier while allowing smooth, adjustable access to the work area. It also helps maintain optimal airflow and works seamlessly with the cabinet's safety interlocks.

Q: What is the recommended process for maintaining the cabinet's filtration efficiency?

A: Regularly monitor the digital display for HEPA filter life and airflow indicators. If a safety alarm is triggered for filter clogging or low airflow, schedule immediate filter replacement or servicing. Weekly cleaning of the removable work surface and UV lamp cycles further optimize cleanliness.

Q: When should the UV germicidal lamp be used, and how does it enhance hygiene?

A: The UV germicidal lamp should be operated between work sessions or overnight. It efficiently deactivates biological contaminants on interior surfaces, reducing microbial load and supporting a sterile environment.

Q: Where should this cabinet be installed for optimal performance?

A: Install the cabinet in a laboratory area with stable power supply and external ducting access. Ensure a level, unobstructed space to accommodate its floor-mounted design and external exhaust requirements as per the provided duct connection dimensions.

Q: How does the digital control system contribute to the cabinet's usability?

A: The digital display enables precise monitoring of airflow, filter status, and safety conditions. Users receive immediate audible and visual alerts, allowing rapid responses to any parameter deviations, thereby supporting continuous safe operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Air Systems Category

AIR SHOWER

AIR SHOWER

Minimum Order Quantity : 1 Piece

Material : Stainless Steel

Warranty : 1 YEAR

Voltage : 220240 V

Frequency : 5060 Hz

Application : CLEAN AIR SYSTEM

Vertical Laminar Air Flow Cabinets

Vertical Laminar Air Flow Cabinets

Minimum Order Quantity : 1 Piece

Material : SS, MS

Warranty : 1 year

Voltage : 220 Volt (v)

Frequency : 50 Hertz (HZ)

Application : Industrial

Laminar Flow Cabinet Digital

Laminar Flow Cabinet Digital

Minimum Order Quantity : 1 Piece

Material : SS, MS

Warranty : 1 year

Voltage : 220240 Volt (v)

Frequency : 50 Hertz (HZ)

Application : Industrial

Air Showers

Air Showers

Minimum Order Quantity : 1 Piece

Material : SS, MS

Warranty : 1 year

Voltage : 230 Volt (v)

Frequency : 50 Hertz (HZ)

Application : Industrial