Binder Extractor Hand Operated Specification

  • Number of Specimens
  • One per operation
  • Display Type
  • Analog / Without Digital Display
  • Response Time
  • Immediate (on manual operation)
  • Specimen Size
  • 1500 g Capacity Bowl
  • Features
  • Cast Aluminum Body, Hand Crank Operation, Solvent Extraction
  • Temperature
  • Ambient
  • Mounting Type
  • Table Top
  • Test Range
  • Up to 1500 g binder
  • Interface Type
  • None (Mechanical)
  • Accuracy
  • 0.5%
  • Application
  • Bitumen Testing Instruments
  • Product Type
  • Binder Extractor Hand Operated
  • Equipment Type
  • Binder Extractor Hand Operated
  • Port Size
  • Standard (as per IS Specifications)
  • Usage
  • Bitumen Testing Instruments
  • Max Height
  • Approx. 350 mm
  • Automation Grade
  • Manual
  • Resolution
  • Fine Control (Hand Operated)
  • Capacity
  • 1500 g
  • Machine Weight
  • Approx. 15 Kg
  • Test Speed
  • Manual (Hand Operated)
  • Control Mode
  • Manual
 

Binder Extractor Hand Operated Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Letter of Credit (L/C), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces, , Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Binder Extractor Hand Operated

Binder Extractor (Hand Operated) :

The Instrument is used for determination and checking of Bitumen percentage in Bituminous mix, the mix is added with a solvent and dissolved bitumen is removed by centrifugal action. Consists of a removable Aluminum rotor bowl, Capacity 1500 gms. With a cap and tightening nut. The bowl assembly is mounted on a vertical shaft, which protrudes from a cast housing. This shaft and thus the bowl is rotated fast manually by enclosed gears in the cast body and handle. Solvent is introduced during the test through the holes in the cap of the housing. A drain is provided to collect dissolved Bitumen coming out of the rotating bowl and getting collected in the housing

Highlights :

  • Highly efficient
  • Low maintenance
  • Market competitive prices
  • Durable machinery



Designed for Reliable Bitumen Extraction

This hand operated binder extractor is engineered to deliver efficient and accurate binder separation for bitumen testing. With a hard-wearing centrifuge bowl, corrosion-resistant body, and precise manual operation, it withstands regular laboratory use. Its standard port sizing and robust construction ensure compatibility and longevity across diverse settings.


Safe and Compatible for Laboratory Environments

Equipped with a safety cover and made from high-grade materials, the extractor supports the use of potent solvents such as trichloroethylene and carbon tetrachloride. The cast aluminum body and powder-coated finish enhance corrosion resistance, promoting safety and minimizing maintenance requirements for busy laboratories.


Effortless Operation and Maintenance

The binder extractor features a smooth steel handle for controlled, manual operation, achieving approximate speeds of 3600 rpm. Simple disassembly makes cleaning and routine maintenance quick and straightforward, while its table-top design and manageable weight add convenience for operators.

FAQs of Binder Extractor Hand Operated:


Q: How is the binder extractor operated and what is the extraction process?

A: The binder extractor is manually operated using a steel crank handle. The process involves placing a specimen of bitumen up to 1500 g in the spun brass bowl, adding a suitable solvent, and rotating the handle. The centrifuge action separates the binder from the mixture for precise testing outcomes.

Q: What types of solvents are compatible with this binder extractor?

A: This device is suitable for use with trichloroethylene and carbon tetrachloride, which are commonly employed in bitumen extraction procedures. Ensure solvents are handled in accordance with laboratory safety protocols when preparing samples.

Q: When should the binder extractor be used in bitumen testing?

A: Use the binder extractor during bitumen testing when accurate separation of binder content is required, typically as part of asphalt quality control or research. Its manual design is best suited for laboratory settings where specimen sizes do not exceed 1500 g.

Q: Where can this binder extractor be installed or mounted?

A: The equipment is designed for table-top mounting in laboratory environments. Its compact form factor and approximate height of 350 mm allow for easy placement on standard laboratory benches or testing tables.

Q: What are the main benefits of using a hand operated binder extractor?

A: Users benefit from fine control over the extraction process, low maintenance requirements, immediate response time, and high accuracy (0.5%). The manual operation ensures direct oversight, making it reliable for small batch and precision testing.

Q: How easy is it to maintain and clean the binder extractor?

A: Maintenance is straightforward due to low complexity and easy disassembly. After each test, users can quickly remove and clean the centrifuge bowl and other components, keeping the unit ready for repeated use with minimal downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Bitumen Testing Instruments Category

Water in Bituminous Material

Water in Bituminous Material

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Benchtop

Usage : Bitumen Testing Instruments

Automation Grade : Manual

Specimen Size : Standard bitumen sample

Elastic  Recovery Mould

Elastic Recovery Mould

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Benchtop

Usage : Bitumen Testing Instruments

Automation Grade : Manual

Specimen Size : Mould for 10 mm 50 mm sample

Ring and Ball Apparatus Electrical

Ring and Ball Apparatus Electrical

Price 10 INR / Piece

Minimum Order Quantity : 1 Piece

Mounting Type : Bench Top

Usage : Bitumen Testing Instruments

Automation Grade : SemiAutomatic

Specimen Size : Standard 28 mm diameter ball

Bitumen Laboratory Mixer

Bitumen Laboratory Mixer

Price 100 INR / Piece

Minimum Order Quantity : 1 , , Piece

Mounting Type : Benchtop

Usage : Bitumen Testing Instruments

Automation Grade : Semiautomatic

Specimen Size : Up to 6 liters container



Back to top