ABSORPTION IN PACKED COLUMN Specification

  • Accuracy
  • 1%
  • Gas Pressure
  • 0.2-2 bar (adjustable)
  • Temperature
  • Ambient to 70C
  • Humidity
  • 5% 95% RH (non-condensing)
  • Resolution
  • 0.01 LPH
  • Automation Grade
  • Manual/Semi-automatic
  • Max Height
  • 1000 mm
  • Product Type
  • ABSORPTION IN PACKED COLUMN
  • Specimen Size
  • Column diameter: 50 mm; Height: 1000 mm (standard)
  • Interface Type
  • Manual valves / digital sensors (optional)
  • Mounting Type
  • Free Standing
  • Frequency
  • 50 Hz
  • Power Supply
  • 230V AC, 50Hz, single phase
  • Display Type
  • Digital/Analog Flow meters
  • Test Range
  • Variable with flow meters
  • Response Time
  • Instant (real-time observation)
  • Measuring Range
  • Flow rate: 0-10 LPH (Liquid), 0-40 LPH (Gas); Absorption efficiency: 0-100%
  • Port Size
  • 1/4 and 1/2 BSP (Gas & Liquid) or as per requirement
  • Number of Specimens
  • Single laboratory unit
  • Application
  • Chemical Engineering Laboratory Equipments
  • Usage
  • Chemical Engineering Laboratory Equipments
  • Operating Voltage
  • 230 V Single phase
  • Features
  • Transparent glass column, variable liquid and gas flow, calibrated flow meters, packed with raschig rings or saddles, corrosion resistant cabinet
  • Capacity
  • Liquid holdup: 23 Liters
  • Machine Weight
  • 50 kg (approx)
  • Control Mode
  • Manual/Automatic
  • Compliance
  • CE certified electricals (on request)
  • Safety Features
  • Over-pressure release valve, emergency shut-off
  • Column Material
  • Borosilicate glass
  • Pump Type
  • Centrifugal pump for liquid circulation
  • Gas Supply
  • Compressed air with regulator
  • Suitable For
  • Academic research, laboratory demonstrations, pilot scale studies
  • Measurement Instruments
  • Rotameters for gas and liquid
  • Equipment Type
  • Laboratory Equipment
  • Cabinet Material
  • Powder coated mild steel
  • Packing Type
  • Raschig rings or plastic saddles
  • Liquid Supply
  • Water or compatible solvent
  • Dimensions (L x W x H)
  • Approx. 1100 mm x 450 mm x 1500 mm
 

ABSORPTION IN PACKED COLUMN Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About ABSORPTION IN PACKED COLUMN

ABSORPTION IN PACKED COLUMN : MTS-905


The absorption column is designed to demonstrate the basics of gas absorption in the unit operations of chemical engineering. A glass absorption column is used to allow mass transfer between the absorption liquid and feed gases within the unit. Students are exposed to the working principle s of a gas absorption column via wetted wall system.

Some of the other features are as follows:

  • Compares absorption characteristics of packed columns.
  • Allows humidification and stripping to be studied.
  • Complete visual monitoring of the process.
  • Easily operated and used.
  • No further development work necessary.
  • Suitable for project or research work.


Versatile Laboratory Equipment

Engineered for use in chemical engineering laboratories, this absorption column is ideal for academic, research, and pilot-scale demonstrations. The transparent borosilicate column provides excellent visibility of the absorption process, making it a valuable learning tool for students and researchers.


Advanced Measurement and Control

Equipped with calibrated rotameters for monitoring gas and liquid flows, the system supports both analog and digital displays. The inclusion of variable flow meters and instant response time allows precise, real-time observation and control of experimental conditions.


Robust Safety and Construction

This packed column features essential safety mechanisms including an over-pressure release valve and emergency shut-off. Constructed with corrosion-resistant materials such as a powder-coated mild steel cabinet and borosilicate glass, it is suitable for long-term laboratory use.

FAQs of ABSORPTION IN PACKED COLUMN:


Q: How does the absorption process operate in this packed column system?

A: The absorption process occurs as gas and liquid streams contact each other within the borosilicate glass column packed with Raschig rings or plastic saddles. The centrifugal pump circulates the liquid, and compressed air provides the gas flow, allowing mass transfer and efficient absorption.

Q: What are the primary applications of this packed column equipment?

A: This equipment is mainly used for academic demonstrations, chemical engineering research, and pilot-scale absorption studies. It is especially useful for studying gas-liquid mass transfer and evaluating absorption efficiency in an educational or laboratory setting.

Q: When should the over-pressure release valve and emergency shut-off be used?

A: The over-pressure release valve and emergency shut-off should be utilized whenever abnormal pressure buildup or emergency conditions are detected. These safety mechanisms help protect users and equipment during operation.

Q: Where can this absorption column be installed?

A: Designed for laboratory environments, the unit can be set up on a free-standing basis in research labs, academic institutions, and pilot-scale testing facilities. Its moderate size and robust construction allow for easy integration into most lab spaces.

Q: What is the process for adjusting gas and liquid flow rates?

A: Flow rates are adjusted using manual valves and monitored through digital or analog rotameters. Real-time flow readings enable users to set desired parameters for accurate and controlled experiments.

Q: How is maintenance conducted for this equipment?

A: Routine maintenance involves periodic cleaning of the glass column, checking for leaks, ensuring that safety valves are functional, and calibrating the flow meters. Follow the manufacturers guidelines for long-term reliability.

Q: What are the benefits of using transparent columns and calibrated flow meters?

A: The transparent borosilicate glass column allows for visual monitoring of the process, aiding educational demonstrations and troubleshooting. Calibrated flow meters ensure precise control and measurements, enhancing data accuracy during experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Chemical Engineering Laboratory Equipments Category

Aerobic Digester

Aerobic Digester

Minimum Order Quantity : 1 Piece

Usage : Chemical Engineering Laboratory Equipments

Product Type : Aerobic Digester

Application : Chemical Engineering Laboratory Equipments

Frequency : 50 Hz

Power Supply : 220 V AC, 50 Hz

Anarobic Digester

Anarobic Digester

Minimum Order Quantity : 1 Piece

Usage : Laboratory Equipments

Frequency : 50 Hertz (HZ)

Power Supply : Electric

R.T.D. STUDIES IN PLUG FLOW TUBULAR REACTOR (STRAIGHT TUBE TYPE) APPARATUS

R.T.D. STUDIES IN PLUG FLOW TUBULAR REACTOR (STRAIGHT TUBE TYPE) APPARATUS

Minimum Order Quantity : 1 Piece

Usage : Chemical Engineering Laboratory Equipments

Product Type : R.T.D. STUDIES IN PLUG FLOW TUBULAR REACTOR (STRAIGHT TUBE TYPE) APPARATUS

Application : Chemical Engineering Laboratory Equipments

Quartz Water Distillation Equipment Cabinet

Quartz Water Distillation Equipment Cabinet

Minimum Order Quantity : 1 Piece

Usage : Chemical Engineering Laboratory Equipments

Product Type : Quartz Water Distillation Equipment Cabinet

Application : Chemical Engineering Laboratory Equipments



Back to top